Background: Digital media exposure is nearly universal by the preschool years. However, little is known about the timing of first exposure to different devices, and the factors associated with earlier exposure. Objective: This study examined age at first exposure to multiple digital devices and investigated sociodemographic, family, and behavioral factors associated with earlier exposure in preschool-aged children. We hypothesized that the timing of exposure would vary according to device-specific family and parental factors. Methods: Cross-sectional data from 892 Portuguese children aged 2 to 6 years were analyzed. Parents reported their children’s age at first exposure to television, video game consoles, computers, tablets, and smartphones. Children not yet exposed were treated as censored observations. Kaplan-Meier analyses estimated the median age at first exposure, and Cox proportional hazards models examined associations with child sex, parental education, parental screen time, and the presence of older siblings. Results: Among 892 children, exposure to digital devices was nearly universal (n=889, 99.7%), with television being the most common device. The median age at first exposure to any device was 12 months, with 581 (65.1%) children exposed by this age. Timing of exposure varied substantially across devices, with the earliest exposure observed for television, followed by smartphones and tablets, whereas computers and video game consoles were introduced later. Associations with earlier exposure differed by device. Earlier video game exposure was associated with being male and having older siblings. Parental screen time was statistically associated with earlier exposure to computers and tablets, although the magnitude of these associations was small. Smartphone exposure was associated with higher paternal education. No consistent factors were observed for television or overall device exposure. Conclusions: Digital device exposure begins during infancy and is widespread by the preschool years, but the timing and associated factors differ across devices. These findings suggest that early digital exposure is not a uniform behavior and support the importance of considering device-specific patterns when examining children’s early media experiences.
Kickboxing is a hybrid striking combat sport characterized by intermittent, acyclic activity that taxes both aerobic and anaerobic energy systems. Yet, physiological data from tatami disciplines such as Kick Light (KL) remain scarce. This exploratory study examined ventilatory thresholds and heart rate (HR) responses in a university kickboxing team comprising eight athletes (six males, two females) across 15 official bouts, focusing on intensity relative to the first and second ventilatory thresholds (VT1, VT2). One week before competition, athletes completed an incremental treadmill test to determine VT1, VT2, and maximum oxygen consumption (VO2max). During competition, HR was continuously monitored to quantify time spent below VT1, between VT1 and VT2, and above VT2, as well as maximal HR during rounds and HR recovery during breaks. VT1 and VT2 occurred at approximately 49% and 90% of VO2max, respectively, with VO2max averaging 52.46 ± 5.14 mL·kg−1·min−1. In competition, athletes spent most of Round 1 between VT1 and VT2, whereas Round 2 showed a shift towards intensities above VT2 (increase in 7 of 8 athletes; p = 0.018). Associations were examined at the athlete level (n = 8) after averaging repeated bout observations within each athlete. Higher VO2max was associated with greater time below VT1 in Round 1 and lower average in-competition HR. These exploratory findings provide preliminary information on cardiovascular responses during official university Kick Light competition and may inform future, larger studies.
Introduction: The primary criterion to validate maximum oxygen consumption ( O 2max ) is the plateau of oxygen consumption ( O 2plat ), a point where oxygen consumption levels off and stops increasing, even when the workload continues to rise. Although a uniformly agreed-upon definition and guidelines for the assessment of O 2plat do not exist. Therefore, this study aimed to compare the O 2plat achieved using a criterion based on each participant’s O 2 change per workload increment with the most used fixed criterion for assessing O 2max . Furthermore, the study intended to demonstrate the consequences of relying solely on O 2plat to confirm a maximal effort. Methods: Thirty-five physically active males (26.7 ± 6.3 years) performed two maximal treadmill protocols separated by a week: using one-minute (1-MIN) and three-minute (3-MIN) stages, both increasing 1 km·h -1 per stage. O 2max was defined when a O 2plat was established between the two consecutive highest 30 s sampling periods, using: 1) Δ O 2 ≤ 50% of the individual submaximal O 2 /speed slope (IND- O 2plat ); 2) Δ O 2 ≤150 mL·min -1 (FIXED- O 2plat ). Results: O 2plat were identified in 85.7% to 97.1% of the tests. No differences were observed between the criteria and protocols in meeting the O 2plat . The mean O 2 /speed slope differed significantly across protocols (p=0.001), indicating that the 3-MIN stage protocols elicited a greater O 2 internal response to the increments than the 1-MIN stages (236.51 ± 56.44 mL·min -1 and 214.21 ± 44.81 mL.min -1 , respectively). 1-MIN protocols achieved higher aerobic power than 3-MIN protocols, regardless of the criterion used. Specifically, using IND- O 2plat , 1-MIN values were 4121.93 ± 516.95 mL·min -1vs. 3-MIN 3950.47 ± 550.28 mL·min -1 (p=0.002); using FIXED- O 2plat , 1-MIN values were 4107.21 ± 521.90 mL·min -1vs. 3-MIN 3953.91 ± 534.16 mL·min -1 (p=0.001). No differences were identified in O 2max despite of whether a O 2plat was attained (concordant and discordant classifications) (p ≤ 0.05). Discussion: The incidence of O 2plat seems to be independent of the criteria used; however, the fixed criterion does not fully account for individual responses to the external load, which do vary according to protocol design. Additionally, the O 2max remains unaltered by the presence of a plateau. Therefore, a different methodological approach needs to be employed to provide a more nuanced validation of the O 2max attainment.