This paper introduces an implementation of a system allowing to denoise the intensity data sensed by a DAS system before analyzing it through a convolutional neural network for train tracking. The results obtained showed that it is possible to track a train by focusing only on the magnitude of signals without caring out complex treatments.
A distributed acoustic sensor (DAS system) with a sensing range of 193.5 km and 10 m of spatial resolution is implemented using mixed amplification methods consisting of Raman and Er-doped optical amplifiers.
We demonstrate the reliability of two coherent detection DAS systems on detecting vibrations generated in a railway environment. Systems have been validated by accelerometers based measurements. A demonstration of a rail vehicle tracking is also performed.
This paper introduces a comparison study between SVM and a convolutional neural network for automatic train moving recognition by exploiting distributed acoustic sensing data. The results show the performance of each of the two methods for such a goal.
Train tracking is an essential need for railway companies. Indeed, monitoring train movements is crucial for safety and traffic management issues. Although train tracking solutions already exist, they are still expensive and have some limitations. The French railway company (SNCF) is investing efforts to exploit emerging state-of-the-art results to develop its own train tracking solution. We present in this article an approach that exploits “Meta’s Segment Anything model” for spatio-temporal train localization on data sensed by a distributed acoustic sensing (DAS) system. We tested our approach on a traffic platform situated in Paris. While we achieved promising results, we also identified certain limitations to this solution.
Distributed Acoustic Sensing (DAS) systems based on -OTDR are increasingly used for real-time infrastructure monitoring, but their performance is limited by coherent and polarization fading, which create signal blind spots along the fiber. This study evaluates two coherent-detection DAS architectures—with and without polarization diversity—together with the influence of optical cable type and ground-coupling method, in an operational railway environment. Field experiments were conducted along a 40 km SNCF (Société Nationale des Chemins de fer Français) railway line using train passages as excitation sources, complemented by controlled sledgehammer tap tests on a 500 m calibration platform connecting four fiber configurations (telecom vs. sensing cables, buried vs. duct-installed). Signal amplitude, differential phase, and phase Median Absolute Deviation (MAD) were used to quantify sensing performance. Polarization diversity reduced the fraction of faded signals below from approximately ≈ to ≈ of the fiber length and improved the Phase Stability Index (PSI) from ≈ to ≈ at 20 km, significantly mitigating polarization-induced signal dropouts across the 40 km span. Among the tested cables, the tight-buffered sensing fiber directly buried in the ground consistently provided the strongest and most stable response, while telecom fiber installed in a High-Density Polyethylene (HDPE) duct showed the weakest coupling. These results demonstrate that combining polarization-diversity detection with an optimized fiber-cable coupling strategy substantially improves the robustness of DAS for railway infrastructure monitoring.