Emilia Peltola

Dr. Emilia Peltola

Department of Electrical Engineering and Automation, School of Electrical Engineering, Aalto University, P.O. Box 13500, 00076 Aalto, Finland

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2017 in Analytical Chemistry
Verified
Journal Article
Closed access
EPEmilia Peltola
Emilia Peltola
SSSami Sainio
Sami Sainio
KHKatherine B. Holt
Katherine B. Holt
TPTommi Palomäki
Tommi Palomäki
JKJari Koskinen
Jari Koskinen
TLTomi Laurila
Tomi Laurila

1 October 2018 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
TPTommi Palomäki
Tommi Palomäki
EPEmilia Peltola
Emilia Peltola
SSSami Sainio
Sami Sainio
NWNiklas Wester
Niklas Wester
OPOlli Pitkänen
Olli Pitkänen
TLTomi Laurila
Tomi Laurila

29 September 2021 in ACS Omega
Verified
Journal Article
Open access
AKAyesha Kousar
Ayesha Kousar
EPEmilia Peltola
Emilia Peltola
TLTomi Laurila
Tomi Laurila
Electrode fouling is a major factor that compromises the performance of biosensors in in vivo usage. It can be roughly classified into (i) electrochemical fouling, caused by the analyte and its reaction products, and (ii) biofouling, caused by proteins and other species in the measurement environment. Here, we examined the effect of electrochemical fouling [in phosphate buffer saline (PBS)], biofouling [in cell-culture media (F12-K) with and without proteins], and their combination on the redox reactions occurring on carbon-based electrodes possessing distinct morphologies and surface chemistry. The effect of biofouling on the electrochemistry of an outer sphere redox probe, [Ru(NH3)6]3+, was negligible. On the other hand, fouling had a marked effect on the electrochemistry of an inner sphere redox probe, dopamine (DA). We observed that the surface geometry played a major role in the extent of fouling. The effect of biofouling on DA electrochemistry was the worst on planar pyrolytic carbon, whereas the multiwalled carbon nanotube/tetrahedral amorphous carbon (MWCNT/ta-C), possessing spaghetti-like morphology, and carbon nanofiber (CNF/ta-C) electrodes were much less seriously affected. The blockage of the adsorption sites for DA by proteins and other components of biological media and electrochemical fouling components (byproducts of DA oxidation) caused rapid surface poisoning. PBS washing for 10 consecutive cycles at 50 mV/s did not improve the electrode performance, except for CNF/ta-C, which performed better after PBS washing. Overall, this study emphasizes the combined effect of biological and electrochemical fouling to be critical for the evaluation of the functionality of a sensor. Thus, electrodes possessing composite nanostructures showed less surface fouling in comparison to those possessing planar geometry.

1 November 2017 in Journal of Materials Chemistry B
Verified
Journal Article
Open access
PDF file
EPEmilia Peltola
Emilia Peltola
JHJoonas Heikkinen
Joonas Heikkinen
KSKatariina Sovanto
Katariina Sovanto
SSSami Sainio
Sami Sainio
AAAnja Aarva
Anja Aarva
TLTomi Laurila
Tomi Laurila
Here we investigated the electrochemical properties and dopamine (DA) detection capability of SU-8 photoresist based pyrolytic carbon (PyC) as well as its biocompatibility with neural cells. This approach is compatible with microfabrication techniques which is crucial for device development. X-ray photoelectron spectroscopy shows that PyC consists 98.5% of carbon, while oxygen plasma treatment (PyC-O2) increases the amount of oxygen up to 27.1%. PyC showed nearly reversible (ΔEp 63 mV) electron transfer kinetics towards outer sphere redox probe (Ru(NH3)6 2+/3+), while the reaction on PyC-O2 was quasi-reversible (ΔEp > 75 mV). DA showed both diffusion and adsorption-defined reaction kinetics with fast electron transfer with the ΔEp values of 50 mV and 30 mV, for PyC and PyC-O2, respectively. The strong interaction between the hydroxyl groups on the surface and DA, as confirmed by simulations, facilitates the redox reactions of DA. DA showed a linear response in the measured physiologically relevant range (50 nM–1 μM) and sensitivities were 1.2 A M−1 cm−2 for PyC and 2.7 A M−1 cm−2 for PyC-O2. Plasma oxidation (PyC-O2) improved cell adhesion even more than poly-L-lysine (PLL) coating on PyC, but best adhesion was achieved on PLL coated PyC-O2. Glial cells, neuroblastoma cells and neural stem cells all showed similar behavior.

1 February 2017 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
EPEmilia Peltola
Emilia Peltola
NWNiklas Wester
Niklas Wester
KHKatherine B. Holt
Katherine B. Holt
LJLeena-Sisko Johansson
Leena-Sisko Johansson
JKJari Koskinen
Jari Koskinen
TLTomi Laurila
Tomi Laurila
We hypothesize that by using integrated carbon nanostructures on tetrahedral amorphous carbon (ta-C), it is possible to take the performance and characteristics of these bioelectrodes to a completely new level. The integrated carbon electrodes were realized by combining nanodiamonds (NDs) with ta-C thin films coated on Ti-coated Si-substrates. NDs were functionalized with mixture of carboxyl and amine groups NDandante or amine NDamine, carboxyl NDvox or hydroxyl groups NDH and drop-casted or spray-coated onto substrate. By utilizing these novel structures we show that (i) the detection limit for dopamine can be improved by two orders of magnitude [from 10µM to 50nM] in comparison to ta-C thin film electrodes and (ii) the coating method significantly affects electrochemical properties of NDs and (iii) the ND coatings selectively promote cell viability. NDandante and NDH showed most promising electrochemical properties. The viability of human mesenchymal stem cells and osteoblastic SaOS-2 cells was increased on all ND surfaces, whereas the viability of mouse neural stem cells and rat neuroblastic cells was improved on NDandante and NDH and reduced on NDamine and NDvox. The viability of C6 cells remained unchanged, indicating that these surfaces will not cause excess gliosis. In summary, we demonstrated here that by using functionalized NDs on ta-C thin films we can significantly improve sensitivity towards dopamine as well as selectively promote cell viability. Thus, these novel carbon nanostructures provide an interesting concept for development of various in vivo targeted sensor solutions.

22 March 2023 in Sensors & Diagnostics
Verified
Journal Article
Open access
PDF file
NDNaela Delmo
Naela Delmo
BMBahar Mostafiz
Bahar Mostafiz
ARAshley E. Ross
Ashley E. Ross
JSJohanna Suni
Johanna Suni
EPEmilia Peltola
Emilia Peltola
Measurements inside the human body are complicated.