Joonas Heikkinen

Mr. Joonas Heikkinen

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2017 in Journal of Materials Chemistry B
Verified
Journal Article
Open access
PDF file
EPEmilia Peltola
Emilia Peltola
JHJoonas Heikkinen
Joonas Heikkinen
KSKatariina Sovanto
Katariina Sovanto
SSSami Sainio
Sami Sainio
AAAnja Aarva
Anja Aarva
TLTomi Laurila
Tomi Laurila
Here we investigated the electrochemical properties and dopamine (DA) detection capability of SU-8 photoresist based pyrolytic carbon (PyC) as well as its biocompatibility with neural cells. This approach is compatible with microfabrication techniques which is crucial for device development. X-ray photoelectron spectroscopy shows that PyC consists 98.5% of carbon, while oxygen plasma treatment (PyC-O2) increases the amount of oxygen up to 27.1%. PyC showed nearly reversible (ΔEp 63 mV) electron transfer kinetics towards outer sphere redox probe (Ru(NH3)6 2+/3+), while the reaction on PyC-O2 was quasi-reversible (ΔEp > 75 mV). DA showed both diffusion and adsorption-defined reaction kinetics with fast electron transfer with the ΔEp values of 50 mV and 30 mV, for PyC and PyC-O2, respectively. The strong interaction between the hydroxyl groups on the surface and DA, as confirmed by simulations, facilitates the redox reactions of DA. DA showed a linear response in the measured physiologically relevant range (50 nM–1 μM) and sensitivities were 1.2 A M−1 cm−2 for PyC and 2.7 A M−1 cm−2 for PyC-O2. Plasma oxidation (PyC-O2) improved cell adhesion even more than poly-L-lysine (PLL) coating on PyC, but best adhesion was achieved on PLL coated PyC-O2. Glial cells, neuroblastoma cells and neural stem cells all showed similar behavior.

9 July 2020 in Physical Chemistry Chemical Physics
Verified
Journal Article
Open access
PDF file
EPEmilia Peltola
Emilia Peltola
AAAnja Aarva
Anja Aarva
SSSami Sainio
Sami Sainio
JHJoonas Heikkinen
Joonas Heikkinen
NWNiklas Wester
Niklas Wester
TLTomi Laurila
Tomi Laurila
Biofouling imposes a significant threat for sensing probes used in vivo. Antifouling strategies commonly utilize a protective layer on top of the electrode but this may compromise performance of the electrode. Here, we investigated the effect of surface topography and chemistry on fouling without additional protective layers. We have utilized two different carbon materials; tetrahedral amorphous carbon (ta-C) and SU-8 based pyrolytic carbon (PyC) in their typical smooth thin film structure as well as with a nanopillar topography templated from black silicon. The near edge X-ray absorption fine structure (NEXAFS) spectrum revealed striking differences in chemical functionalities of the surfaces. PyC contained equal amounts of ketone, hydroxyl and ether/epoxide groups, while ta-C contained significant amounts of carbonyl groups. Overall, oxygen functionalities were significantly increased on nanograss surfaces compared to the flat counterparts. Neither bovine serum albumin (BSA) or fetal bovine serum (FBS) fouling caused major effects on electron transfer kinetics of outer sphere redox (OSR) probe Ru(NH3)6 3+ on any of the materials. In contrast, negatively charged OSR probe IrCl6 2− kinetics were clearly affected by fouling, possibly due to the electrostatic repulsion between redox species and the anionically-charged proteins adsorbed on the electrode and/or stronger interaction of the proteins and positively charged surface. The OSR probe kinetics were less affected by fouling on PyC, probably due to conformational changes of proteins on the surface. Dopamine (DA) was tested as an inner sphere redox (ISR) probe and as expected, the kinetics were heavily dependent on the material; PyC had very fast electron transfer kinetics, while ta-C had sluggish kinetics. DA electron transfer kinetics were heavily affected on all surfaces by fouling (ΔEp increase 30–451%). The effect was stronger on PyC, possibly due to the more strongly adhered protein layer limiting the access of the probe to the inner sphere.

31 July 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
JHJoonas Heikkinen
Joonas Heikkinen
EPEmilia Peltola
Emilia Peltola
NWNiklas Wester
Niklas Wester
JKJari Koskinen
Jari Koskinen
TLTomi Laurila
Tomi Laurila
VJVille Jokinen
Ville Jokinen
Pattern formation of pyrolyzed carbon (PyC) and tetrahedral amorphous carbon (ta-C) thin films were investigated at micro- and nanoscale. Micro- and nanopillars were fabricated from both materials, and their biocompatibility was studied with cell viability tests. Carbon materials are known to be very challenging to pattern. Here we demonstrate two approaches to create biocompatible carbon features. The microtopographies were 2 μ m or 20 μ m pillars (1:1 aspect ratio) with three different pillar layouts (square-grid, hexa-grid, or random-grid orientation). The nanoscale topography consisted of random nanopillars fabricated by maskless anisotropic etching. The PyC structures were fabricated with photolithography and embossing techniques in SU-8 photopolymer which was pyrolyzed in an inert atmosphere. The ta-C is a thin film coating, and the structures for it were fabricated on silicon substrates. Despite different fabrication methods, both materials were formed into comparable micro- and nanostructures. Mouse neural stem cells were cultured on the samples (without any coatings) and their viability was evaluated with colorimetric viability assay. All samples expressed good biocompatibility, but the topography has only a minor effect on viability. Two μ m pillars in ta-C shows increased cell count and aggregation compared to planar ta-C reference sample. The presented materials and fabrication techniques are well suited for applications that require carbon chemistry and benefit from large surface area and topography, such as electrophysiological and -chemical sensors for in vivo and in vitro measurements.

14 July 2020 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Open access
PDF file
JHJoonas Heikkinen
Joonas Heikkinen
JKJanez Košir
Janez Košir
VJVille Jokinen
Ville Jokinen
SFSami Franssila
Sami Franssila
Fabrication of suspended pyrolytic carbon 3D-microstructures from SU–8 was studied in variable pyrolysis temperatures. The dimensions of suspended parts were from 3 µ m to 1500 µ m in length with one to four anchor points. The pyrolysis temperatures were 800 °C to 1100 °C, and the resulting pyrolysed carbon structures were analyzed in terms of shrinkage, surface roughness, electrical resistivity and carbon bond type. The structural stability of the suspended structures is strongly dependent on the number of anchor points. The successful parameter range, structure design rules and the common failure mechanisms are discussed. The temperature dependency on material properties is studied and analyzed. We observed changes in three stages of the pyrolysis process that impact on the final structural shape and stability.

1 January 2018 in Frontiers in Cellular Neuroscience
Verified
Journal Article
Open access
JHJoonas Heikkinen
Joonas Heikkinen
VRVille Rontu
Ville Rontu
EPEmilia Peltola
Emilia Peltola
TKTiina Kaarela
Tiina Kaarela
NWNiklas Wester
Niklas Wester
SFSami Franssila
Sami Franssila
The aim of the research is to study carbon material feasibility for neuron electrophysiological measurements. Carbon materials possess many advantageous and unique properties compared to conventional biocompatible materials used widely in neuronal arrays. Here we study fabrication techniques for applying patterned carbon thin films on top of complex microstructures with the goal of utilizing them in 3D microelectrode arrays. Nerve cells act as data highways in multicellular animals, and they have strict demands for their surrounding environment in order to grow successfully and to create neuronal networks. Studying neurons and neuronal networks in vitro has been challenging because of limitations of neurocompatible materials. Carbon has showed promising results not only with its neurocompatibility, but also with other properties like electrical conductivity, low toxicity, chemical inertness, and thin film transparency. Many of these properties can be tailored by adjusting the chemical bonds between carbon atoms. With these properties, carbon films allow neuronal cultivation, networking, and measurements (optical and electrical) in single dish without the need of transferring the culture, which is a high-risk process for cell population’s health and morphology. In our previous research, we have successfully fabricated microelectrode arrays (MEA) with carbon as the active material that is in contact with the cells (publication under peer-review). Many of the available MEAs have indium tin oxide (ITO) as the conductive material for electrodes, because it is transparent and allows optical inspection. However, usually the electrode tip, which is in contact with studied sample, is opaque material (like platinum black) to have a higher neurocompatibility or surface area compared to ITO. The carbon films we use in our research are highly sp2 bonded diamond like carbons (DLC), which possess good electrical conductivity and optical transparency. In our current research, we aim to increase the MEA electrode surface area by creating 3D microstructures (e.g. micropillars). 3D structures not only increase the surface area, but also changes the topography of the substrate where neurons attach. The effect of both properties are under study. We create the pillars from either silicon or copper, and passivate the surface with atomic layer deposition (ALD) film. The chosen materials are used for different application: the copper pillars are further roughened with wet etching creating nanopores to increase the surface area drastically while the silicon pillars are sharpened to act as needles. In the case of copper, the high surface area will have a high impact on electrode impedance and signal-to-noise ratio, which are crucial to develop MEAs with better sensitivity, whereas the sharp silicon needles are used to measure acute brain slices. Both pillar types are protected with two thin films: first with an ALD thin film, and then with sputtered tetrahedral amorphous carbon (ta-C) film which has the most important role of being in contact with the sample. The roles of different materials in our fabrication process is as follows: copper has high electrical conductivity, and it is possible to roughen it with easy methods, allowing us to increase the surface area. Silicon has good mechanical properties and it enables the fabrication of long, strong, and sharp needles that can be punctured through tissue. ALD is a conformal process that allows a pinhole free durable coating of even the most complex 3D structures, and with correct material selection, we can negate all possible toxicity the core materials may possess. Finally, the critical carbon layer is applied on top of all layers to provide a neurocompatible cell interface.