The past two decades have witnessed the adverse effects of low-frequency components of severe earthquakes in low-frequency structures. The development of displacement control technologies for the seismic protection of low-frequency structures has been identified as a growing challenge in earthquake engineering. Related studies have suggested that rate-independent linear damping (RILD) could be a viable option for reducing excessive displacements in low-frequency structures. However, previous studies on RILD systems have not extensively investigated their input energy during an earthquake. The main objective of this study is to examine the earthquake input energy of low-frequency structures equipped with a passive rate-independent damping device. The differences in the input energy of the linear viscous damping (LVD) and RILD systems are investigated, based on real-time hybrid simulations and frequency-domain analysis.
9 January 2024 in Structural Control and Health Monitoring
Compared with conventional linear viscous damping (LVD), rate‐independent linear damping (RILD) mitigates floor response acceleration in low‐frequency structures more effectively without compromising the control performance of displacement responses during long‐period or low‐frequency earthquakes. Although theoretical and experimental attempts have been made to overcome the noncausality of RILD devices and realize RILD using passive or semiactive devices, only a few studies have highlighted the impulse‐response precursor and modal analysis method of multistory structures incorporated into RILD devices. This study investigated the impulse‐response precursor of a noncausal RILD system and proposed a novel modal decomposition method for the structures equipped with nonproportionally distributed RILD devices. Additionally, real‐time hybrid simulation was conducted to validate the effectiveness of the proposed modal analysis method and the feasibility of realizing ideal RILD using mechanical devices. This study is the first to demonstrate the differences between RILD and LVD devices in terms of controlling the modal responses of low‐frequency structures and how RILD can lower the floor response acceleration more effectively compared to LVD.
10 February 2022 in Structural Control and Health Monitoring
In the 2011 Great East Japan Earthquake, low-frequency components of ground motion brought long-duration shaking to high-rise buildings in mega-cities far from the epicenter, resulting in damage to their interior and exterior walls, and unsafe conditions for the building occupants. Rate-independent linear damping (RILD) has been suggested as a viable option for simultaneously reducing the excessive displacement and floor response acceleration of a low-frequency structure. While the majority of previous studies on RILD have mainly focused on theoretical and mathematical approaches, the practical applications of RILD have not been extensively investigated. In this regard, this study aims to experimentally and analytically investigate the physical implementation of RILD for the protection of a multistory low-frequency structure. The effectiveness of the proposed passive causal RILD device, comprising a Maxwell-type damper and negative stiffness, incorporated into a seismically isolated building was investigated based on real-time hybrid simulation. Under strong ground motions, the passive causal RILD device could greatly reduce the floor response accelerations in the seismically isolated structure, compared with a linear viscous damping device.