Andrey Aksenov

Dr. Andrey Aksenov

Saint Petersburg Electrotechnical University “LETI”
+1
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2014 in Prosthetics and Orthotics International
Verified
Journal Article
Closed access
MAMokhtar Arazpour
Mokhtar Arazpour
SHStephen W Hutchins
Stephen W Hutchins
MBMonireh A Bani
Monireh A Bani
SCSarah Curran
Sarah Curran
Andrey AksenovAndrey Aksenov
Andrey Aksenov
Patients suffering from mild-to-moderate medial compartment knee osteoarthritis may be treated with an unloader knee orthosis. However, compliance has been shown to be an issue with such devices. The aim of this study was to identify the effects of a new design of knee unloader orthosis on specific gait parameters in patients with mild-to-moderate medial knee osteoarthritis. The gait of seven patients was assessed in two conditions: without an orthosis and when wearing a new design of unloader knee orthosis. Gait analysis was performed to determine alterations to the adduction moment, speed of walking, step length, cadence and knee sagittal plane range of motion during ambulation for the two test conditions. The knee adduction moment was significantly reduced (p = 0.001), and the speed of walking significantly increased (p < 0.001) when wearing the orthosis. However, a reduction in knee range of motion (p = 0.002) and an increase in step length (p < 0.001) were observed with the orthosis donned. Cadence was not significantly altered (p = 0.504). The use of a new design of unloader knee orthosis as a conservative treatment approach for patients with mild-to-moderate medial compartment osteoarthritis appears warranted. Various conservative modalities have been used to reduce pain and improve function in medial compartment osteoarthritis. A new design of an unloader knee orthosis has been developed and is shown to have immediate benefits in patients with mild medial knee osteoarthritis.

10 June 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TKTatiana Klishkovskaia
Tatiana Klishkovskaia
Andrey AksenovAndrey Aksenov
Andrey Aksenov
Aleksandr SinitcaAleksandr Sinitca
Aleksandr Sinitca
AZAnna Zamansky
Anna Zamansky
Oleg MarkelovOleg Markelov
Oleg Markelov
Dmitrii KaplunDmitrii Kaplun
Dmitrii Kaplun
The rapid development of algorithms for skeletal postural detection with relatively inexpensive contactless systems and cameras opens up the possibility of monitoring and assessing the health and wellbeing of humans. However, the evaluation and confirmation of posture classifications are still needed. The purpose of this study was therefore to develop a simple algorithm for the automatic classification of human posture detection. The most affordable solution for this project was through using a Kinect V2, enabling the identification of 25 joints, so as to record movements and postures for data analysis. A total of 10 subjects volunteered for this study. Three algorithms were developed for the classification of different postures in Matlab. These were based on a total error of vector lengths, a total error of angles, multiplication of these two parameters and the simultaneous analysis of the first and second parameters. A base of 13 exercises was then created to test the recognition of postures by the algorithm and analyze subject performance. The best results for posture classification were shown by the second algorithm, with an accuracy of 94.9%. The average degree of correctness of the exercises among the 10 participants was 94.2% (SD1.8%). It was shown that the proposed algorithms provide the same accuracy as that obtained from machine learning-based algorithms and algorithms with neural networks, but have less computational complexity and do not need resources for training. The algorithms developed and evaluated in this study have demonstrated a reasonable level of accuracy, and could potentially form the basis for developing a low-cost system for the remote monitoring of humans.

18 August 2014 in Prosthetics and Orthotics International
Verified
Journal Article
Open access
JHJohn Head
John Head
DHDavid Howard
David Howard
SHStephen W Hutchins
Stephen W Hutchins
LKLaurence Kenney
Laurence Kenney
GHGlyn Harvey Heath
Glyn Harvey Heath
Andrey AksenovAndrey Aksenov
Andrey Aksenov
Usable myoelectric control relies on secure and intimate contact at all times between the electrode, the socket and the residual limb. At present, there is little post-fitting socket adjustment available to prosthetists with respect to electrode contact security or alignment. Failure to provide secure electrode contact could result in the development of motion artefacts, poor prehensor response and subsequent prosthesis non-usage. To establish the effect of alteration to electrode contract security and alignment on prosthesis functionality using a bespoke electrode housing unit. This study investigated the effect of electrode contact security and alignment on upper limb myoelectric prosthesis functionality. Four different electrode housing arrangements were assessed within prosthetic sockets fitted to six transradial prosthesis subjects using the Southampton Hand Assessment Procedure, which is a reliable and validated prosthesis functionality assessment tool. Significantly higher functionality scores were achieved with the bespoke housing unit compared to when using conventional electrode housings. Myoelectric prosthesis functionality is closely linked to electrode contact security and to electrode alignment with respect to the residual limb. Both of these factors can be improved locally using an adjustable electrode housing unit. Provision of an electrode housing system that enables adjustments to be made to electrode orientation can improve prosthesis functionality, particularly in cases where tight-fitting sockets are not possible, and/or where the prosthetist may be inexperienced with regard to myoelectric prosthesis fitting.

1 December 2013 in Prosthetics and Orthotics International
Verified
Journal Article
Open access
MAMokhtar Arazpour
Mokhtar Arazpour
SHStephen W Hutchins
Stephen W Hutchins
FGFarhad Tabatabai Ghomsheh
Farhad Tabatabai Ghomsheh
FSFahimeh Shaky
Fahimeh Shaky
MKMasome V Karami
Masome V Karami
Andrey AksenovAndrey Aksenov
Andrey Aksenov
The most commonly prescribed external shoe modification is the use of rocker soles. The aim of this study was to evaluate the effect of a heel-to-toe rocker sole profile on specific temporal–spatial parameters and the kinematics of walking when added to footwear. Seventeen healthy adult volunteers participated in this study. For each subject, gait analysis was performed under two conditions that were tested in a random order: walking with either a baseline shoe with a flat sole or a modified shoe adapted with a heel-to-toe rocker sole. Significant differences were observed between rocker sole conditions during initial double-limb support and second double-limb support during stance phase. In frontal plane movement, significant differences were observed between the rocker sole conditions but only during second double-limb support phase. This heel-to-toe rocker sole may be useful for patients with conditions such as ankle arthrodesis or for use with ankle–foot orthoses where limited ankle motion is required. The heel-to-toe rocker sole may be useful for conditions including ankle arthrodesis and for use with solid ankle–foot orthoses but may not be suitable for patients with reduced balance or an unstable posture.

1 March 2012 in Journal of Vascular Nursing
Verified
Journal Article
Closed access
SHStephen William Hutchins
Stephen William Hutchins
GLGwen Lawrence
Gwen Lawrence
SBStephen Blair
Stephen Blair
Andrey AksenovAndrey Aksenov
Andrey Aksenov
RJRichard Jones
Richard Jones

28 March 2019 in Genij Ortopedii
Verified
Journal Article
Closed access
Andrey AksenovAndrey Aksenov
Andrey Aksenov
GHG.H. Heath
G.H. Heath
TKT.A. Klishkovskaya
T.A. Klishkovskaya
TDT.I. Dolganova
T.I. Dolganova
RCRussian Ilizarov Scientific Centre
Russian Ilizarov Scientific Centre