Anuwat Saenpong

Dr. Anuwat Saenpong

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2024 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
NBNuntawat Butwong
Nuntawat Butwong
SSSarawut Saenkham
Sarawut Saenkham
APAdisak Pattiya
Adisak Pattiya
ASAnuwat Saenpong
Anuwat Saenpong
AMAphichon Mungchu
Aphichon Mungchu
Sopa CanseeSopa Cansee
Sopa Cansee

5 November 2025 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
ASAnuwat Saenpong
Anuwat Saenpong
PPPitak Promthaisong
Pitak Promthaisong
BWBhadpiroon Watcharasresomroeng
Bhadpiroon Watcharasresomroeng
BBBopit Bubphachot
Bopit Bubphachot

23 September 2026 in Insects
Verified
Journal Article
Open access
PDF file
AMAphichon Mungchu
Aphichon Mungchu
SSSarawut Saenkham
Sarawut Saenkham
ASAnuwat Saenpong
Anuwat Saenpong
CTChinnapat Turakarn
Chinnapat Turakarn
Sopa CanseeSopa Cansee
Sopa Cansee
Fresh black soldier fly larvae (BSFL) have a high moisture content that complicates storage and requires energy-intensive postharvest drying. This study evaluated the effects of drying-air temperature and tray rotation speed on BSFL drying kinetics, energy performance, and moisture transport in a rotating-tray hot-air dryer. A 3 × 3 factorial experiment was conducted at 50, 60, and 70 °C and tray rotation speeds of 0, 5, and 10 rpm, with three independent replicates, while drying-air velocity was maintained at 3.0 m s−1. Drying time decreased from 31.0 h at 50 °C and 0 rpm to 6.5 h at 70 °C and 10 rpm. The latter condition achieved the highest drying efficiency (49.11%) and lowest specific energy consumption (4.60 MJ kg−1 water removed). Comparable values were obtained at 60 °C and 10 rpm (49.07% and 4.61 MJ kg−1 water removed, respectively). Among nine thin-layer models evaluated for the six rotating-tray treatments at 5 and 10 rpm, the Midilli model provided the best fit. Apparent effective moisture diffusivity (Deff) increased from 0.2457 × 10−9 to 1.2946 × 10−9 m2 s−1, while apparent activation energy ranged from 67.39 to 68.46 kJ mol−1. Rotating-tray drying accelerated BSFL dehydration and improved engineering performance; however, microbial safety and product quality require separate evaluation before food or feed recommendations can be made.

25 September 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
ASAnuwat Saenpong
Anuwat Saenpong
AMAphichon Mungchu
Aphichon Mungchu
CTChinnapat Turakarn
Chinnapat Turakarn
SJSawanee Jansawang
Sawanee Jansawang
SASasen
Sasen
Opposed parabolic V–winglets (PVWs) are evaluated as passive longitudinal-vortex generators for enhancing convection in circular tubes. Three–dimensional steady Reynolds averaged simulations were performed for turbulent air flow through a uniformly heated tube containing opposed PVWs on a central tape. Pitch ratio (PR) = 0.5–2.0, blockage ratio (BR)= 0.1– 0.5, attack angle (α) = 30°–60°, and Reynolds number (Re) = 3000–24,000 were varied under a uniform wall heat flux of 600 W m⁻². The realizable k-ε model was used to resolve turbulent kinetic energy, wall-temperature fields, local heat transfer, and global thermohydraulic performance. The inserts generated counter-rotating streamwise vortices, walldirected jets, separation and reattachment, and repeated thermal-boundary-layer renewal. The Nusselt-number ratio (Nu/Nu0) and Darcy friction factor ratio (f/f0) were 1.396–7.901 and 2.590–140.673, respectively. Although heat transfer increased with BR and decreasing PR, the pressure-loss penalty rose nonlinearly. The thermal enhancement factor (TEF) ranged from 0.531 to 2.327 and generally decreased with Re. The maximum TEF of 2.327 occurred at BR = 0.2, PR = 0.5, α = 30°, and Re = 3000, whereas the maximum Nu/Nu0 occurred at BR = 0.5 and α = 45°. Thus, moderate blockage and close spacing provide a better equal pumping power compromise than the most obstructive geometry.