29 April 2021 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
LBLorenz Büchler
Lorenz Büchler
VGValentin Ma Grob
Valentin Ma Grob
HAHelen Anwander
Helen Anwander
TLTill Dominic Lerch
Till Dominic Lerch
PHPascal Cyrill Haefeli
Pascal Cyrill Haefeli
Background: Arthroscopic treatment of symptomatic femoroacetabular impingement (FAI) has promising short-term to mid-term results. In addition to treating acute pain or impaired function, the goal of hip-preserving surgery is to achieve a lasting improvement of hip function and to prevent the development of osteoarthritis. Long-term results are necessary to evaluate the effectiveness of surgical treatment and to further improve results by identifying factors associated with conversion to THA. Questions/purposes: (1) How do the Merle d’Aubigné-Postel scores change from before surgery to follow-up of at least 10 years in patients undergoing hip arthroscopy for the treatment of FAI? (2) What is the cumulative 10-year survival rate of hips with the endpoints of conversion to THA or a Merle d’Aubigné-Postel score less than 15? (3) Which factors are associated with conversion to THA? Methods: Between 2003 and 2008, we treated 63 patients (65 hips) for symptomatic FAI with hip arthroscopy at our institution. During that period, the indications for using arthroscopy were correction of anterior cam morphology and anterolateral rim trimming with debridement or reattachment of the labrum. We excluded patients who were younger than 16 years and those who had previous trauma or surgery of the hip. Based on that, 60 patients (62 hips) were eligible. A further 17% (10 of 60) of patients were excluded because the treatment was purely symptomatic without treatment of cam- and/or pincer-type morphology. Of the 50 patients (52 hips) included in the study, 2% (1) of patients were lost before the minimum study follow-up of 10 years, leaving 49 patients (51 hips) for analysis. The median (range) follow-up was 11 years (10 to 17). The median age at surgery was 33 years (16 to 63). Ninety percent (45 of 50) of patients were women. Of the 52 hips, 75% (39 of 52) underwent cam resection (femoral offset correction), 8% (4 of 52) underwent acetabular rim trimming, and 17% (9 of 52) had both procedures. Additionally, in 35% (18 of 52) of hips the labrum was debrided, in 31% (16 of 52) it was resected, and in 10% (5 of 52) of hips the labrum was reattached. The primary clinical outcome measurements were conversion to THA and the Merle d’Aubigné-Postel score. Kaplan-Meier survivorship and Cox regression analyses were performed with endpoints being conversion to THA or Merle d’Aubigné-Postel score less than 15 points. Results: The clinical result at 10 years of follow-up was good. The median improvement of the Merle d’Aubigné-Postel score was 3 points (interquartile range 2 to 4), to a median score at last follow-up of 17 points (range 10 to 18). The cumulative 10-year survival rate was 92% (95% CI 85% to 99%) with the endpoints of conversion to THA or Merle d’Aubigné-Postel score less than 15. Factors associated with conversion to THA were each year of advancing age at the time of surgery (hazard ratio 1.1 [95% CI 1.0 to 1.3]; p = 0.01) and preoperative Tönnis Grade 1 compared with Tönnis Grade 0 (no sign of arthritis; HR 17 [95% CI 1.8 to 166]; p = 0.01). Conclusion: In this series, more than 90% of patients retained their native hips and reported good patient-reported outcome scores at least 10 years after arthroscopic treatment of symptomatic FAI. Younger patients fared better in this series, as did hips without signs of osteoarthritis. Future studies with prospective comparisons of treatment groups are needed to determine how best to treat complex impingement morphologies. Level of Evidence: Level IV, therapeutic study.

13 November 2022 in Medicina
Verified
Journal Article
Open access
PDF file
TPTorsten Pastor
Torsten Pastor
IZIvan Zderic
Ivan Zderic
CSClemens Schopper
Clemens Schopper
PHPascal Cyrill Haefeli
Pascal Cyrill Haefeli
PKPhilipp Kastner
Philipp Kastner
Matthias KnobeMatthias Knobe
Matthias Knobe
Background and Objectives: Intramedullary nailing of trochanteric fractures can be challenging and sometimes the clinical situation does not allow perfect implant positioning. The aim of this study was (1) to compare in human cadaveric femoral heads the biomechanical competence of two recently launched cephalic implants inserted in either an ideal (centre–centre) or less-ideal anterior off-centre position, and (2) to investigate the effect of bone cement augmentation on their fixation strength in the less-ideal position. Materials and Methods: Fourty-two paired human cadaveric femoral heads were assigned for pairwise implantation using either a TFNA helical blade or a TFNA screw as head element, implanted in either centre–centre or 7 mm anterior off-centre position. Next, seven paired specimens implanted in the off-centre position were augmented with bone cement. As a result, six study groups were created as follows: group 1 with a centre–centre positioned helical blade, paired with group 2 featuring a centre–centre screw, group 3 with an off-centre positioned helical blade, paired with group 4 featuring an off-centre screw, and group 5 with an off-centre positioned augmented helical blade, paired with group 6 featuring an off-centre augmented screw. All specimens were tested until failure under progressively increasing cyclic loading. Results: Stiffness was not significantly different among the study groups (p = 0.388). Varus deformation was significantly higher in group 4 versus group 6 (p = 0.026). Femoral head rotation was significantly higher in group 4 versus group 3 (p = 0.034), significantly lower in group 2 versus group 4 (p = 0.005), and significantly higher in group 4 versus group 6 (p = 0.007). Cycles to clinically relevant failure were 14,919 ± 4763 in group 1, 10,824 ± 5396 in group 2, 10,900 ± 3285 in group 3, 1382 ± 2701 in group 4, 25,811 ± 19,107 in group 5 and 17,817 ± 11,924 in group 6. Significantly higher number of cycles to failure were indicated for group 1 versus group 2 (p = 0.021), group 3 versus group 4 (p = 0.007), and in group 6 versus group 4 (p = 0.010). Conclusions: From a biomechanical perspective, proper centre–centre implant positioning in the femoral head is of utmost importance. In cases when this is not achievable in a clinical setting, a helical blade is more forgiving in the less ideal (anterior) malposition when compared to a screw, the latter revealing unacceptable low resistance to femoral head rotation and early failure. Cement augmentation of both off-centre implanted helical blade and screw head elements increases their resistance against failure; however, this effect might be redundant for helical blades and is highly unpredictable for screws.

27 August 2021 in Medicina
Verified
Journal Article
Open access
PDF file
KKKenneth van Knegsel
Kenneth van Knegsel
Bergita GanseBergita Ganse
Bergita Ganse
PHPascal Cyrill Haefeli
Pascal Cyrill Haefeli
Filippo MiglioriniFilippo Migliorini
Filippo Migliorini
Mario F. ScaglioniMario F. Scaglioni
Mario F. Scaglioni
Matthias KnobeMatthias Knobe
Matthias Knobe
Background and Objectives: Wound infections provoked by alterations in microcirculation are major complications in the treatment of trochanteric femur fractures. Surgical fracture fixation on a traction table is the gold standard for treatment, but the effect on tissue microcirculation is unknown. Microcirculation could be impaired by the pull on the soft-tissue or by a release of vasoactive factors. We hypothesized that intraoperative traction impairs soft-tissue microcirculation. Materials and Methods: In 22 patients (14 women, eight men), average age 78 years (range 36–96 ± 14), with trochanteric femur fractures, non-invasive laser-Doppler spectrophotometry was used to assess oxygen saturation, hemoglobin content, and blood flow in the skin and subcutaneous tissue before and after application of traction. Measurements were recorded in nine locations around the greater trochanter at a depth of 2, 8, and 15 mm before and after fracture reduction by traction. Results: No differences were found in any depth with traction compared to without (oxygen saturation: p = 0.751, p = 0.308, and p = 0.955, haemoglobin content: p = 0.651, p = 0.928, and p = 0.926, blood flow: p = 0.829, p = 0.866, and p = 0.411). Conclusion: In this pilot study, the application of traction does not affect skin and subcutaneous microcirculation in the surgery of proximal femur fractures.

27 December 2024 in Operative Orthopädie und Traumatologie
Verified
Journal Article
Closed access
PDF file
PHPascal Cyrill Haefeli
Pascal Cyrill Haefeli
GSGeorg Schelling
Georg Schelling
RBRalf Baumgärtner
Ralf Baumgärtner
DCDe-Hua Chang
De-Hua Chang
BLBjörn-Christian Link
Björn-Christian Link

13 October 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
DEDaniel Elias
Daniel Elias
BWBryan van de Wall
Bryan van de Wall
JBJörg Bucher
Jörg Bucher
BLBjörn-Christian Link
Björn-Christian Link
PHPascal Cyrill Haefeli
Pascal Cyrill Haefeli
Background/Objectives: Mixing implant components from different manufacturers in primary total hip arthroplasty (THA) remains controversial because of concerns regarding implant compatibility and revision risk. This systematic review and meta-analysis aimed to compare revision outcomes between brand-mixed and brand-unmixed primary THA. Methods: A PRISMA-compliant systematic review of PubMed/MEDLINE and Embase identified studies comparing brand-mixed and brand-unmixed primary THA. Reported time-to-event estimates were pooled as hazard ratios (HRs), and revision-event counts as odds ratios (ORs), using random-effects models. Results: Six retrospective observational studies comprising 1,185,948 primary THAs were included. The time-to-event analysis did not identify a statistically significant difference in all-cause revision between brand-mixed and brand-unmixed THA (HR 1.03; 95% CI 0.97–1.08; I2 = 0%). The complementary crude revision-event analysis likewise did not identify a statistically significant difference (OR 1.01; 95% CI 0.83–1.24), although substantial heterogeneity was present (I2 = 93%). A post hoc exploratory sensitivity analysis excluding metal-on-metal and ceramic-on-metal bearings and brand-mixed stem–head constructs was based on two studies and yielded an OR of 0.97 (95% CI 0.79–1.20; I2 = 95%). Certainty of evidence was low for the time-to-event analysis and very low for the event-based analyses. Conclusions: Available observational evidence did not identify a statistically significant association between brand mixing and all-cause revision following primary THA. However, these findings do not establish equivalence, universal component compatibility, or the safety of specific brand-mixed combinations and should be interpreted in light of the observational study designs, residual confounding, and heterogeneity in implant constructs.