Background Robotically performed neurointerventional surgery has the potential to reduce occupational hazards to staff, perform intervention with greater precision, and could be a viable solution for teleoperated neurointerventional procedures. Objective To determine the indication, robotic systems used, efficacy, safety, and the degree of manual assistance required for robotically performed neurointervention. Methods We conducted a systematic review of the literature up to, and including, articles published on April 12, 2021. Medline, PubMed, Embase, and Cochrane register databases were searched using medical subject heading terms to identify reports of robotically performed neurointervention, including diagnostic cerebral angiography and carotid artery intervention. Results A total of 8 articles treating 81 patients were included. Only one case report used a robotic system for intracranial intervention, the remaining indications being cerebral angiography and carotid artery intervention. Only one study performed a comparison of robotic and manual procedures. Across all studies, the technical success rate was 96% and the clinical success rate was 100%. All cases required a degree of manual assistance. No studies had clearly defined patient selection criteria, reference standards, or index tests, preventing meaningful statistical analysis. Conclusions Given the clinical success, it is plausible that robotically performed neurointerventional procedures will eventually benefit patients and reduce occupational hazards for staff; however, there is no high-level efficacy and safety evidence to support this assertion. Limitations of current robotic systems and the challenges that must be overcome to realize the potential for remote teleoperated neurointervention require further investigation.
16 February 2022 in Journal of NeuroInterventional Surgery
Background Flow diversion is an innovative and increasingly used technique for the treatment of intracranial aneurysms. New flow diverters (FDs) are being introduced to improve the safety and efficacy of this treatment. The aim of this study was to assess the safety, feasibility, and efficacy of the new Pipeline Vantage (PV) FD. Methods Patients with intracranial aneurysms treated with the PV at 10 international neurovascular centers were retrospectively analyzed. Patient and aneurysm characteristics, procedural parameters, complications, and the grade of occlusion were assessed. Results 60 patients with 70 aneurysms (5.0% with acute hemorrhage, 90.0% located in the anterior circulation) were included. 82 PVs were implanted in 61 treatment sessions. The PV could be successfully implanted in all treatments. Additional coiling was performed in 18.6%, and in-stent balloon angioplasty (to enhance the vessel wall apposition) in 24.6%. Periprocedural technical complications occurred in 24.6% of the treatments, were predominantly FD deployment problems, and were all asymptomatic. The overall symptomatic complication rate was 8.2% and the neurological symptomatic complication rate was 3.3%. Only one symptomatic complication was device-related (perforator artery infarctions leading to stroke). After a mean follow-up of 7.1 months, the rate of complete aneurysm occlusion was 77.9%. One patient (1.7%) died due to aneurysmal subarachnoid hemorrhage which occurred before treatment, unrelated to the procedure. Conclusions The new PV FD is safe and feasible for the treatment of intracranial aneurysms. The short-term occlusion rates are promising but need further assessment in prospective long-term follow-up studies.
Stroke remains one of the leading causes of death and disability in Europe. The European Stroke Action Plan (ESAP) defines four main targets for the years 2018 to 2030. The COVID-19 pandemic forced the use of innovative technologies and created pressure to improve internet networks. Moreover, 5G internet network will be helpful for the transfer and collecting of extremely big databases. Nowadays, the speed of internet connection is a limiting factor for robotic systems, which can be controlled and commanded potentially from various places in the world. Innovative technologies can be implemented for acute stroke patient management soon. Artificial intelligence (AI) and robotics are used increasingly often without the exception of medicine. Their implementation can be achieved in every level of stroke care. In this article, all steps of stroke health care processes are discussed in terms of how to improve them (including prehospital diagnosis, consultation, transfer of the patient, diagnosis, techniques of the treatment as well as rehabilitation and usage of AI). New ethical problems have also been discovered. Everything must be aligned to the concept of “time is brain”.
14 November 2019 in American Journal of Neuroradiology
BACKGROUND AND PURPOSE: The recently introduced Pipeline Flex Embolization Device with Shield Technology (Pipeline Shield) is the third generation of Pipeline flow-diverter devices. It has a new stent-surface modification, which reduces thrombogenicity. We aimed to evaluate clinical and radiographic (safety and efficacy) outcomes of the Pipeline Shield. MATERIALS AND METHODS: The 30-day and 1-year mortality and morbidity rates and the 6- and 18-month radiographic aneurysm occlusion outcomes for procedures performed between March 2016 and January 2018 were analyzed. 3D-TOF-MRA was used for follow-up. RESULTS: Forty-four attempted Pipeline Shield procedures were performed for 41 patients with 44 target aneurysms (total of 52 aneurysms treated). A total of 88.5% of devices were inserted in the anterior circulation, and 11.5%, in the posterior circulation; 49/52 (94.2%) aneurysms were saccular; and 1/52 (1.9%) was fusiform. One (1.9%) aneurysm was an iatrogenic pseudoaneurysm, and 1 (1.9%) was a dissecting aneurysm. Seventy-one percent (35/49) of the saccular aneurysms were wide-neck (neck, >4 mm), 34.6% (18/52) were large (≥10 mm), and 3.8% (2/52) were giant (≥25 mm). The mean aneurysm sac maximal diameter was 9.0 mm, and the mean neck width was 5.0 mm. The cumulative mortality and morbidity rates were 2.3% and 6.8% at 1 year, respectively. The adequate occlusion rate was 78.8% at 6 months and 90.3% at 18 months. CONCLUSIONS: In this pragmatic and non-industry-sponsored study, the occlusion rates and safety outcomes were similar to those seen in previously published studies with flow-diverter devices and earlier generation Pipeline Embolization Devices.