Igor Poljak

Dr. Igor Poljak

Maritime Department, University of Zadar, Mihovila Pavlinovića 1, 23000 Zadar, Croatia
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 June 2017 in Applied Thermal Engineering
Verified
Journal Article
Closed access
Vedran MrzljakVedran Mrzljak
Vedran Mrzljak
Igor PoljakIgor Poljak
Igor Poljak
VMVedran Medica-Viola
Vedran Medica-Viola

1 January 2019 in Brodogradnja
Verified
Journal Article
Open access
Vedran MrzljakVedran Mrzljak
Vedran Mrzljak
Igor PoljakIgor Poljak
Igor Poljak
Jasna Prpic-OrsicJasna Prpic-Orsic
Jasna Prpic-Orsic

6 February 2017 in Brodogradnja
Verified
Journal Article
Open access
PDF file
Vedran MrzljakVedran Mrzljak
Vedran Mrzljak
Igor PoljakIgor Poljak
Igor Poljak
VMVedran Medica-Viola
Vedran Medica-Viola
Nowadays diesel engines prevail as ship propulsion. However, steam propulsion is still primary drive for LNG carriers. In the presented paper high-pressure feed water heater was analyzed, as one of the essential components in LNG carrier...

Verified
Journal Article
Open access
PDF file
IGIvan Gospić
Ivan Gospić
Ivica GlavanIvica Glavan
Ivica Glavan
Igor PoljakIgor Poljak
Igor Poljak
Vedran MrzljakVedran Mrzljak
Vedran Mrzljak
The paper discusses the possibility of applying the trigeneration energy concept (cogeneration + absorption cooling) on diesel-powered refrigerated ships, based on systematic analyses of variable energy loads during the estimated life of the ship on a predefined navigation route. From a methodological point of view, mathematical modeling of predictable energy interactions of a ship with a realistic environment yields corresponding models of simultaneously occurring energy loads (propulsion, electrical and thermal), as well as the preferred trigenerational thermal effect (cooling and heating). Special emphasis is placed on the assessment of the upcoming total heat loads (refrigeration and heating) in live cargo air conditioning systems (unfrozen fruits and vegetables) as in ship accommodations. The obtained results indicate beneficiary energy, economic and environmental effects of the application of diesel engine trigeneration systems on ships intended for cargo transport whose storage temperatures range from −25 to 15 °C. Further analysis of trigeneration system application to the passenger ship air conditioning system indicates even greater achievable savings.

17 January 2020 in Entropy
Verified
Journal Article
Open access
PDF file
Igor PoljakIgor Poljak
Igor Poljak
JOJosip Orović
Josip Orović
Vedran MrzljakVedran Mrzljak
Vedran Mrzljak
DBDean Bernečić
Dean Bernečić
Data from a two-stage axial vapor cryogenic compressor on the dual-fuel diesel–electric (DFDE) liquefied natural gas (LNG) carrier were measured and analyzed to investigate compressor energy and exergy efficiency in real exploitation conditions. The running parameters of the two-stage compressor were collected while changing the main propeller shafts rpm. As the compressor supply of vaporized gas to the main engines increases, so does the load and rpm in propulsion electric motors, and vice versa. The results show that when the main engine load varied from 46 to 56 rpm at main propulsion shafts increased mass flow rate of vaporized LNG at a two-stage compressor has an influence on compressor performance. Compressor average energy efficiency is around 50%, while the exergy efficiency of the compressor is significantly lower in all measured ranges and on average is around 34%. The change in the ambient temperature from 0 to 50 °C also influences the compressor’s exergy efficiency. Higher exergy efficiency is achieved at lower ambient temperatures. As temperature increases, overall compressor exergy efficiency decreases by about 7% on average over the whole analyzed range. The proposed new concept of energy-saving and increasing the compressor efficiency based on pre-cooling of the compressor second stage is also analyzed. The temperature at the second stage was varied in the range from 0 to −50 °C, which results in power savings up to 26 kW for optimal running regimes.