18 October 2019 in Veterinary and Comparative Orthopaedics and Traumatology
Verified
Journal Article
Closed access
PDF file
JKJakub Kaczmarek
Jakub Kaczmarek
Tomasz BartkowiakTomasz Bartkowiak
Tomasz Bartkowiak
RSRiccarda Schuenemann
Riccarda Schuenemann
Piotr PaczosPiotr Paczos
Piotr Paczos
Bartosz GapińskiBartosz Gapiński
Bartosz Gapiński
MUMartin Unger
Martin Unger
Objective The aim of this study was to compare the locking compression plate (LCP) with polyaxial locking system (PLS) using single cycle to failure 4-point bending test and to investigate the behaviour of PLS with screws inserted mono- and polyaxially using cyclic fatigue test in two bending directions. Materials and Methods Tests were performed on bone surrogates in a fracture gap model. The 3.5 LCP and 3.5 PLS plates were tested in single cycle to failure. The 3.5 PLS plates with mono- and polyaxial screws were compared in a cyclic fatigue tests in two orthogonal directions. For both experiments, micro-computed tomography (CT) scans were performed pre- and post-testing to investigate the connections between the screw head and the plate hole. Means of forces and cycles needed to failure were statistically compared. Results The PLS plates were on average 30% weaker than LCP plates. Mode of failure was plate bending in the single cycle to failure tests, and plate breakage in the cyclic fatigue tests. Neither screw breakage nor loss of the screw–plate interface occurred. Mono- and polyaxial constructs performed similarly when loaded in the same direction. Micro-CT revealed no additional internal cracks in the plates or screws after testing. It also showed for both PLS and LCP that there was only partial contact of the screw head with the plate hole. Clinical Relevance PLS offers a durable locking system, even when the screws are placed polyaxially. The weaker bending properties of the PLS compared with LCP should be considered during preoperative planning.

15 July 2022 in Veterinary and Comparative Orthopaedics and Traumatology
Verified
Journal Article
Closed access
PDF file
JKJakub Kaczmarek
Jakub Kaczmarek
Tomasz BartkowiakTomasz Bartkowiak
Tomasz Bartkowiak
PPPiotr Paczos
Piotr Paczos
PZPaweł Zawadzki
Paweł Zawadzki
DŁDaria Łączna
Daria Łączna
BGBartosz Gapiński
Bartosz Gapiński
Objective The aim of this study was to evaluate the effect of screw insertion angle and insertion torque on the mechanical properties of a 3.5 fixed-angle locking plate locking compression plate (LCP) and 3.5 variable-angle locking plate polyaxial locking system (PLS). Methods In the LCP group, screws were placed abaxially at 0, 5 and 10 degrees. In the PLS group, screws were placed at 0, 5, 10, 15 and 20 degrees abaxially. The insertion torque was set to 1.5 and 2.5 Nm in the LCP and PLS groups respectively. A load was applied parallel to the screw axis, and the screw push-out force was measured until the locking mechanism was loosened. Results The 3.5 LCP showed higher push-out strength than the 3.5 PLS when the screws were placed at 0 degree regardless of the insertion torque. The off-axis insertion of 3.5 LCP locking screws resulted in a significant decrease in push-out strength (p < 0.05). A higher insertion torque value significantly increased the screw holding strength for the 3.5 LCP (p < 0.05). The 3.5 PLS system had a significantly higher push-out force when the screws are at 0 degree than at 5, 10 and 15 degrees, and 20 degrees (p < 0.05) at any given insertion torque. An increase in the insertion torque did not have a significant effect on the push-out strength of the 3.5 PLS locking system. Conclusion The 3.5 PLS is more sensitive to the screw insertion angle than to the insertion torque, whereas the 3.5 LCP is affected by both factors. Placing 3.5 LCP locking screws off-axis significantly reduces the screw holding strength; therefore, this approach has to be avoided. The findings of our research indicate that a 1.5 Nm torque can be used for a 3.5 PLS.

26 June 2020 in Veterinary and Comparative Orthopaedics and Traumatology
Verified
Journal Article
Closed access
PDF file
JKJakub Kaczmarek
Jakub Kaczmarek
Tomasz BartkowiakTomasz Bartkowiak
Tomasz Bartkowiak
PPPiotr Paczos
Piotr Paczos
BGBartosz Gapinski
Bartosz Gapinski
HJHanna Jader
Hanna Jader
MUMartin Unger
Martin Unger
Objective To quantify the amount of the screw head thread and the plate hole thread connection in two 3.5 mm locking plates: Locking Compression Plate (LCP) and Polyaxial Locking System (PLS). Materials and Methods A micro - CT scan of a screw head - plate hole connection was performed pre- and post destructive tests. Tests were performed on bone surrogates in a fracture gap model. The 3.5 LCP and 3.5 PLS plates, with 3 perpendicular screws per segment were used in a destructive static test. The 3.5 PLS plates with mono- and polyaxial screws were compared in a cyclic fatigue tests in two orthogonal directions. Pre - and post - test scan datasets were compared. Each dataset was converted into serial images depicting sections cut orthogonally to locking screw axis. The amount of engagement was detected through automated image postprocessing. Results The mean amount of the thread connection for the LCP was 28.85% before and 18.55% after destructive static test. The mean amount of the connection for the PLS was 16.20% before and 14.55% after destructive static test. When inserted monoaxially, the mean amount of the connection for the PLS screws was 14.4% before and 19.24% after destructive cyclic test. The mean amount of the connection for the polyaxial inserted PLS screws when loaded against plate thickness was 2.99% before and 2.08% after destructive cyclic test. The mean amount of the connection for the polyaxial inserted PLS screws when loaded against plate width was 3.36% before and 3.93% after destructive cyclic test. The 3D visualization of the thread connection showed that the initial interface points between screw head and plate hole are different for both LCP and PLS after the destructive testing. Depending on the type of applied force, there was either loss or increase of the contact. Clinical Relevance Micro-CT offers news possibilities in locking implant investigation. It might be helpful in better understanding the nature of locking mechanism and prediction of possible mode of failure in different systems.

30 August 2023 in Materials
Verified
Journal Article
Open access
PDF file
Tomasz BartkowiakTomasz Bartkowiak
Tomasz Bartkowiak
DMDaria Madalińska
Daria Madalińska
PMPatryk Mietliński
Patryk Mietliński
JKJakub Kaczmarek
Jakub Kaczmarek
Bartosz GapińskiBartosz Gapiński
Bartosz Gapiński
Piotr PaczosPiotr Paczos
Piotr Paczos
This study demonstrates a new method for quantifying thread engagement in mechanical connections and verifies its applicability using biomedical implants under push-out tests. The focus is on orthopedic plate implants employed for bone fracture fixation, which, by design, allow off-axis screw insertion to accommodate different contact conditions. Thread engagement is crucial in determining connection strength and stability. In medical practice, off-axis screw placement is usually necessary due to bone geometries and implant plate rigidity. To address this, the study proposes a quantification method using non-destructive testing with X-ray micro-computed tomography and automated image processing, although tuning the image processing parameters is vital for accurate and reliable results. This enables detailed 3D models of screw-plate interfaces for precise thread engagement measurement. The results show that thread engagement decreases with both, increased off-axis insertion angles and higher torque during insertion. Correlation analysis reveals a strong relationship (R2 > 0.6) between average thread engagement and push-out strength, underscoring the importance of proper screw placement for stable fixation.

11 September 2026 in Animals
Verified
Journal Article
Open access
PDF file
AMAnna Michalska
Anna Michalska
JKJakub Kaczmarek
Jakub Kaczmarek
DKDaniel Kaup
Daniel Kaup
ALAnnika Lehmbecker
Annika Lehmbecker
MMMagdalena Morawska-Kozłowska
Magdalena Morawska-Kozłowska
Aneurysmal bone cysts (ABCs) are benign but locally aggressive osteolytic lesions that are rarely reported in dogs and may progress or recur following surgical treatment. This case report describes the diagnosis, surgical management, postoperative progression, and long-term outcome of an ABC affecting the left ulna of a four-month-old Labrador Retriever. Radiography and computed tomography revealed a rapidly progressive, expansile osteolytic lesion with marked cortical thinning. Histopathological examination supported the diagnosis of ABC, with no evidence of malignancy. Initial treatment consisted of corticotomy, intralesional curettage, autologous bone grafting, and stabilization of the cortical segment with lag screws. Despite complete clinical resolution of lameness, surveillance radiographs six weeks postoperatively demonstrated progression of the lesion proximal to the original surgical site. Revision surgery involving a larger cortical window and more extensive curettage was subsequently performed, followed by bone grafting. Histopathology again confirmed ABC without malignant transformation. The dog regained normal limb function, and serial radiographic and computed tomographic examinations demonstrated progressive osseous remodeling with no evidence of further progression or recurrence through 35 months of follow-up. This case highlights the importance of adequate surgical excision and scheduled postoperative imaging, as ABC progression may occur despite apparent clinical recovery.