SAHLI Abderahmane

SAHLI Abderahmane

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2024 in Mechanics of Advanced Materials and Structures
Verified
Journal Article
Closed access
OKOmar Khatir
Omar Khatir
SFS. M. Fekih
S. M. Fekih
SASAHLI Abderahmane
SAHLI Abderahmane
IBI. Boudjemaa
I. Boudjemaa
ABA. Benkhettou
A. Benkhettou
BBBel Abbes Bachir Bouiadjra
Bel Abbes Bachir Bouiadjra

10 December 2024 in Mechanics of Advanced Materials and Structures
Verified
Journal Article
Closed access
KOKhatir Omar
Khatir Omar
FMFekih Sidi Mohamed
Fekih Sidi Mohamed
AHAtef Hamada
Atef Hamada
SASAHLI Abderahmane
SAHLI Abderahmane
MYMurat Yaylaci
Murat Yaylaci
BBBelabbes Bachir Bouiadjraa
Belabbes Bachir Bouiadjraa

22 June 2021 in Fracture and Structural Integrity
Verified
Journal Article
Open access
PDF file
IBIsmail Boudjemaa
Ismail Boudjemaa
SASAHLI Abderahmane
SAHLI Abderahmane
ABA. Benkhettou
A. Benkhettou
SBS. Benbarek
S. Benbarek
A lot of trans-femoral amputation patients experience skin breakdown due to the pressures and shear stresses in the stump-prosthesis interface. In this study, a finite element model was employed to investigate the stresses at the stump interface in the case of an orthopedic implant fixed to the cut end of the femur. By changing the stiffness of this implant, we aim to see how the stiffness of this implant affects the stresses in the interface between the amputated limb and the prosthesis. To find out the effects of implant stiffness, five values for the elastic modulus, ranging from 0.1 to 0.5 Mpa, with an interval of 0.1 Mpa were employed in the implant structure of the FE model. Obtained results show that the implant played important role in reducing the stresses at the stump-prosthesis interface where the contact pressure did not exceed 53 Kpa and 17.3 Kpa for shear stress in the stiffer case of an implant, while the contact pressure in the case of femur without implant exceeded 79Kpa and 42 Kpa for shear stress. We also noted that the intensity of the contact pressure and the shear stress is proportional to the stiffness of the implant, as the greater the implant stiffness, the higher the peak of these stresses.

10 May 2020 in Fracture and Structural Integrity
Verified
Journal Article
Open access
PDF file
MAMoulgada Abdelmadjid
Moulgada Abdelmadjid
ZSZagane Mohammed El Sallah
Zagane Mohammed El Sallah
SASAHLI Abderahmane
SAHLI Abderahmane
ADAit Kaci Djafar
Ait Kaci Djafar
ZRZahi Rachid
Zahi Rachid
The purpose of this study is to analyze the behavior of a crack with and without reinforcement by a composite patch of an aluminum plate in mode I using the finite element method. The repair patch is boron / epoxy and Carbon / epoxy, which are used with great success by many researchers For the distribution of the stresses according to the various loadings, we can conclude that the effect of repair by patch in composite is very distinct, considering the intensities of stresses which decrease for each repair corresponding to the plate not repaired, therefore, the patch in composite dampens the stress field induced at the crack tip and causes a reduction in stresses. The repair with the Bore / epoxy composite patch is more effective than the Carbon/Epoxy patch, this is due to the mechanical properties and the various characteristics specific to boron/Epoxy which gives very significant and very effective results for the repair

28 March 2021 in Fracture and Structural Integrity
Verified
Journal Article
Open access
PDF file
AMAbdelmadjid Moulgada
Abdelmadjid Moulgada
DKDjafar Ait Kaci
Djafar Ait Kaci
MZMohammed El Sallah Zagane
Mohammed El Sallah Zagane
SASAHLI Abderahmane
SAHLI Abderahmane
ZRZahi Rachid
Zahi Rachid
This research is based on the study of the fatigue behavior of an aluminum alloy plate with a central crack. The plate is subjected to a tensile loading on its lower and upper parts. Several parameters were highlighted, such as the loading effect with a load ratio R = 0. The effects of the load ratio on both the repaired and not repaired plates, by two composite patches, which are boron/epoxy and graphite/epoxy, were investigated, as well as the effect of the plate material on plate life, comparing different materials

22 March 2020 in Fracture and Structural Integrity
Verified
Journal Article
Open access
PDF file
SASAHLI Abderahmane
SAHLI Abderahmane
FMFouzia Merabbi
Fouzia Merabbi
ALAbdelkader Lousdad
Abdelkader Lousdad
AMAbdelkader Megueni
Abdelkader Megueni
C Composite materials are most often used for lengthier and thin structures susceptible to buckle. The optimization is often carried out taking into consideration the resistance to buckling and tensile loads for minimum displacement i.e maximization of the tensile load for composite assembly joint. It well known that nowadays that composite material in structural mechanics is widely used in many industrial sectors such as in aerospace and aeronautic, automobile, marine industries as well as in and civil engineering. Composite materials are attractive due to their advantages and performance i.e: lighter weights, high resistance to thermal and mechanical loads, resistance to corrosion and wear. In this paper an investigation is focused on the problem of hybrid assembly joint (bolted –bonded) composite structures. The aim is the optimization of the main influencing parameters. A bonded assembly has only one advantage which is its lightness; on the other hand bolted assembly has the inconvenient of increasing the weight of the structure and stress concentrators. In practice certain structural designs require the use of hybrid assembly for safety and reliability. The objective of this study is to optimize the influencing factors using both Genetic Algorithm and design of experiments for high mechanical performance of hybrid composite assembly.