Uta Biedermann

Dr. Uta Biedermann


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
FKFelix Christian Kohler
Felix Christian Kohler
PSPhilipp Schenk
Philipp Schenk
TNTheresa Nies
Theresa Nies
JHJakob Hallbauer
Jakob Hallbauer
GHGunther Olaf Hofmann
Gunther Olaf Hofmann
BUBernhard Wilhelm Ullrich
Bernhard Wilhelm Ullrich
In the treatment of ankle fractures, complications such as wound healing problems following open reduction and internal fixation are a major problem. An innovative alternative to this procedure offers a more minimally invasive nail stabilization. The purpose of this biomechanical study was to clarify whether this method was biomechanically comparable to the established method. First, the stability (range of motion, diastasis) and rotational stiffness of the native upper ankle were evaluated in eight pairs of native geriatric specimens. Subsequently, an unstable ankle fracture was created and fixed with a locking plate or a nail in a pairwise manner. The ankles showed significantly less stability and rotational stiffness properties after nail and plate fixations than the corresponding native ankles (p < 0.001 for all parameters). When comparing the two methods, both showed no differences in their range of motion (p = 0.694) and diastasis (p = 0.166). The nail also presented significantly greater rotational stiffness compared to the plate (p = 0.001). However, both fixations remained behind the native stability and rotational stiffness. Due to the comparable biomechanical properties of the nail and plate fixations, an early weight-bearing following nail fixation should be assessed on a case-by-case basis considering the severity of fractures.

Verified
Journal Article
Open access
PDF file
JHJakob Hallbauer
Jakob Hallbauer
PSPhilipp Schenk
Philipp Schenk
LHLea Herrmann
Lea Herrmann
BUBernhard Wilhelm Ullrich
Bernhard Wilhelm Ullrich
UBUta Biedermann
Uta Biedermann
FKFelix Christian Kohler
Felix Christian Kohler
The hook test is a widely used intraoperative method for assessing syndesmosis stability. However, there are no recommendations regarding the force required to perform this test. Furthermore, the reliability of the test is unclear. Ten experienced surgeons performed hook tests on a cadaver bone model. The applied forces were recorded in a blinded manner. In addition, standardized hook tests with defined forces (50, 80, and 100 N) were performed on 10 pairs of cadaver lower legs and the syndesmosis was sequentially destabilized. Diastasis of the syndesmosis was recorded using an optical 3D camera system. A median force of 81 N (Range: 50 N–145 N) was applied. A proportion of 82% of the tests showed a force < 100 N. The data showed good intraraterreliability and poor interraterreliability. In the standardized investigation of the hook test on the cadaver bone model, both the force and the instability of the syndesmosis had a significant influence on the syndesmosis diastasis. Nevertheless, even with maximum instability of the syndesmosis, diastasis > 2 mm could only be measured in 12 of the 19 evaluable specimens. The widely used hook test shows a high variability when performed in practice. Even in a standardized manner, the hook test cannot detect a relevant syndesmosis injury.

Verified
Journal Article
Open access
PDF file
KKKajetan Klos
Kajetan Klos
PSPaul Simons
Paul Simons
PSPauline Schopp
Pauline Schopp
PSPhilipp Schenk
Philipp Schenk
FKFelix Christian Kohler
Felix Christian Kohler
MLMark Lenz
Mark Lenz
Plantar plate positioning has been demonstrated as biomechanically superior. However, some operators remain resentful about the morbidity of the surgical approach. To provide improved plate fixation for first tarsometatarsal joint arthrodesis with respect to the tibialis anterior tendon, a medio-plantar plate was developed. The purpose of this biomechanical study was to compare its construct stability to that of a plantar plate construct. Twelve pairs of fresh frozen human specimens were used in a matched pair test. Each pair was fixed with a 4 mm compression screw and either a plantar locking plate or a medio-plantar locking plate. A cantilever beam test was performed in dorsiflexion. Before and after cyclic loading (5000 cycles; 40 N), bending stiffness and relative movements at the joint space were monitored in a quasi-static test including optical motion tracking. Maximum load and bending moment to failure were investigated in a load-to-failure ramp test. The bending stiffness of both groups did not significantly differ before (plantar 49.9 N/mm ± 19.2; medio-plantar 53.9 N/mm ± 25.4, p = 0.43) or after (plantar 24.4 N/mm ± 9.7; medio-plantar 35.3 N/mm ± 22.0, p = 0.08) cyclic loading but decreased significantly in both groups (p < 0.01) after cyclic loading. Relative movement increased significantly during cyclic testing in both groups (p < 0.01) but did not differ significantly between the groups before (p = 0.29) or after (p = 0.16) cyclic loading. Neither load nor bending moment to failure were significantly different (plantar 225 N ± 78, 10.8 Nm; medio-plantar 210 N ± 86, 10.1 Nm, p = 0.61). Both plate constructs provided equivalent construct stability, both being well suited for Lapidus arthrodesis.

10 August 2026 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Open access
PDF file
LDLena Dietz
Lena Dietz
CSChristian Spiegel
Christian Spiegel
FKFelix Christian Kohler
Felix Christian Kohler
UBUta Biedermann
Uta Biedermann
IZIvan Zderic
Ivan Zderic
WWWolfram Weschenfelder
Wolfram Weschenfelder
Purpose: To investigate the biomechanical influence of distal screw number in palmar plate fixation of unstable intra-articular distal radius fractures with radiodorsal metaphyseal comminution. Methods: Nine matched pairs of cryopreserved human radii were prepared using a standardized AO/OTA 2R3 C2.1 fracture model with a defined radiodorsal metaphyseal defect zone. For each pair, specimens were randomized to palmar fixation using a 2.4-mm variable-angle locking plate with either four or six distal screws. After embedding, constructs were subjected to cyclic axial loading (150 N, 5,000 cycles) simulating early postoperative rehabilitation. Global axial deformation and fragment-specific three-dimensional interfragmentary motion were recorded using an optical motion-tracking system. Statistical analysis was performed using non-parametric tests ( p < 0.05). Results: Two specimens from one donor pair were excluded, leaving 16 radii (8 pairs) for analysis. Bone mineral density and initial construct stiffness did not differ between groups. The six-screw configuration showed significantly lower axial deformation after cyclic loading ( p = 0.047) and lower radial fragment–shaft translation at both time points ( p = 0.028; p = 0.045). Radial fragment–shaft rotation was lower in the six-screw group at baseline ( p = 0.018), but no rotational difference remained after cyclic loading. In the overall cohort, axial deformation decreased after cyclic loading ( p = 0.015). Conclusion: In this unstable intra-articular fracture model with radiodorsal metaphyseal comminution, six distal screws reduced post-cyclic axial deformation and radial fragment–shaft micromotion compared with four screws. The clinical relevance of these findings remains to be determined.

11 April 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FKFelix Christian Kohler
Felix Christian Kohler
PSPhilipp Schenk
Philipp Schenk
PKPaul Köhler
Paul Köhler
BWBritt Wildemann
Britt Wildemann
GHGunther Olaf Hofmann
Gunther Olaf Hofmann
JHJakob Hallbauer
Jakob Hallbauer
Insufficient fixation of a posterior malleolus fracture (PM) can lead to posttraumatic complications such as osteoarthritis and chronic pain. The purpose of this biomechanical study was to test the hypothesis of whether the direction of PM screw fixation has an impact on the primary stability of osteosynthesis of a PM under torsional loading. PM fractures of 7 pairs human cadaveric lower leg specimens were stabilized with posterior to anterior (p.a.) or anterior to posterior (a.p.) screw fixation. Stability of the osteosynthesis was biomechanically tested using cyclic external torsional loading levels, in 2 Nm steps from 2 Nm up to 12 Nm, under constant monitoring with 3D ultrasonic marker (Zebris). The primary stability does not differ between both stabilizations (p = 0.378) with a medium effect size (η2p = 0.065). The movement of the PM tends to be marginally greater for the osteosynthesis with a.p. screws than with p.a. screws. Whether a.p. screws or the alternative p.a. screw fixation is performed does not seem to have an influence on the primary stability of the osteosynthesis of the PM fixation under torsional loading. Although osteosynthesis from posterior seems to be more stable, the biomechanical results in the torsional test show quite equivalent stabilities. If there is no significant dislocation of the PM, a.p. screw fixation could be a minimally invasive but stable surgical strategy.

20 September 2026 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
Heiko StarkHeiko Stark
Heiko Stark
KJKenny Jandausch
Kenny Jandausch
ARAngelina Roth
Angelina Roth
UBUta Biedermann
Uta Biedermann
MKMartin Krämer
Martin Krämer
Orlando Guntinas-LichiusOrlando Guntinas-Lichius
Orlando Guntinas-Lichius
The facial muscles are crucial for nonverbal communication, physiological functions, and articulation. Unlike skeletal or masticatory muscles, they lack fascia, attach directly to the skin and function without joint-mediated movements or visual feedback. The aim of this study was to reconstruct the facial musculature using high-resolution computerised tomography (CT) and 3 Tesla magnetic resonance imaging (MRI) on 14 body donors, yielding segmented 3D datasets of the facial muscles, as well as bony and soft-tissue head structures. We hypothesise that the facial musculature comprises functional subunits with variable geometries that extend beyond classical anatomical definitions, with attachment points and three-dimensional positioning that differ from conventional descriptions. The most significant finding was that MRI could not resolve individual facial muscles as depicted in anatomical atlases. Instead, the musculature appeared as a single continuous sheet of muscle, embedded in fatty tissue and not attached to the bone. Whether the facial musculature is in fact continuous or consists of several muscles connected by connective tissue remains unclear. The difficulty of segmentation varied depending on the region; the zygomatic muscle was the easiest to separate, whilst the orbicularis oculi, frontalis and platysma muscles proved particularly difficult due to their thin, flat morphology.