Introduction. Microgrids (MGs) have garnered significant attention for their numerous advantages, providing a solution for powering remote and distant locations while enhancing system reliability. In MGs, distributed generation inverters generally operate in parallel with the droop control strategies. This study focuses on the approach based on the P-f/Q-V droop control technique with virtual impedance for AC MG management. Essentially, the virtual impedance loop aims to decouple reactive and active power control without the need for additional physical components. Novelty. This research proposes enhancing voltage control in AC MG systems by introducing new methods of various control strategies, including PI and Fuzzy Logic Controller (FLC), and evaluating the effectiveness of each approach. The mathematical model of a system is always an approximation of real systems, variations or errors between mathematical models and real systems are referred to as uncertainty. This concept of uncertainty is present in both signals and models. In our study, uncertainties may involve factors related to the filter LC components. By employing advanced control strategies like FLC, the purpose of this research aims to contribute to the optimization and reliability of AC MG systems through the improvement of voltage control, which leads to guaranteed equitable power-sharing. Results. The major advantages of the FLC are robustness for any variation on the system and fast response. MATLAB software is used to simulate and validate the suggested control. Practical value. The simulation results show that the suggested control performs better in precise tracking optimization and robustness for all disturbances on the system compared to a PI controller. References 24, table 5, figures 11.
21 October 2023 in Electrical Engineering & Electromechanics
Introduction. Recently, the number of high and medium voltage applications has increased dramatically. The connection between these different applications requires series-parallel combinations of power semiconductors. Multilevel converter topologies provide major advantages to these applications. In this paper, a grid-connected photovoltaic system with a hybrid energy storage system using a five-level neutral point clamped inverter is studied. Although the multilevel inverter has many advantages over the two-level inverter, it has a high probability of experiencing an open circuit fault. In this context, the five-level inverter has 24 controllable switches, one of which may experience an open circuit fault at any time. Therefore, it plays an important part in the reliability and robustness of the whole system. The novelty of this paper presents an approach to accurately detect the open circuit fault in all insulated gate bipolar transistors of a five-level neutral point clamped inverter in a photovoltaic power generation application with a hybrid energy storage system. Purpose. Before using fault-tolerant control to ensure service continuity, fault diagnosis techniques must first be used, which are the crucial phase of reliability. Methods. A detection method based on the maximum and minimum error values is proposed. These errors are calculated using the expected and measured line-to-line pole voltages. Results. The open circuit fault detection method is implemented using MATLAB/Simulink. Simulation results showed the accuracy of detecting the open circuit fault in all insulated gate bipolar transistors in a short time. Moreover, this method is adaptable to several applications and is also robust to transient regimes imposed by solar irradiation and load variations.
Advanced control strategies for inverter-based distributed energy resources (DERs) are essential to ensure stable, reliable, and high-quality operation of modern islanded microgrids (MGs) as renewable energy penetration increases. This paper proposes a hybrid optimal control framework that combines a Linear Quadratic Regulator (LQR) with a Proportional–Integral (PI) controller and integrates droop control with a virtual impedance technique to improve the dynamic performance, power-sharing capability, and power quality of inverter-based MGs. The PI controller regulates the inverter current, while the LQR provides optimal state feedback to improve transient response and disturbance rejection. Primary droop control enables decentralized active and reactive power sharing, whereas secondary control restores voltage and frequency to their nominal values following load disturbances. Furthermore, the virtual impedance technique mitigates the adverse effects of line impedance mismatches and improves power-sharing accuracy among distributed generators. The proposed control strategy was validated through MATLAB/Simulink simulations that accounted for dynamic load variations. Compared with a conventional PI controller, the proposed hybrid LQR–PI approach reduced the frequency settling time from 0.5 s to 0.2 s, decreased the voltage recovery time from 0.5 s to 0.25 s, and achieved reduced voltage and current total harmonic distortion (THD) compared with the conventional PI control, despite the higher control energy. The optimal state feedback provided by the LQR contributed to improved transient performance, while the virtual impedance technique enhanced system robustness and maintained accurate power sharing under uncertain operating conditions. The obtained results demonstrate that the proposed control framework provides an effective and computationally efficient solution for next-generation inverter control in islanded MGs, offering enhanced dynamic stability, improved power quality, and reliable operation of renewable-energy-based distributed power systems.