Mohamed Mosaad

Prof. Dr. Mohamed Mosaad

Assoc. Prof. Dr. / Yanbu Industrial college
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2021 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
MSM.M. Samy
M.M. Samy
Mohamed MosaadMohamed Mosaad
Mohamed Mosaad
SBShimaa Barakat
Shimaa Barakat

31 December 2020 in IEEE Access
Verified
Journal Article
Open access
Mohamed AhmedMohamed Ahmed
Mohamed Ahmed
Mohamed MosaadMohamed Mosaad
Mohamed Mosaad
MEMohamed F. El-Naggar
Mohamed F. El-Naggar
SBShimaa Barakat
Shimaa Barakat
Developing countries’ energy sector faces a multitude of challenges, ranging from inadequate generation to unstable grids. Power outages are among the most common issues, particularly in remote areas. Utilizing grid-tied green energy resources to address this issue and to cover for power outages from local grids. This paper presents a cost-effective design of a grid-tied, hybrid green energy system (GES) consisting of wind, PV, and batteries considering the influence of the grid availability. A multi-objective, optimal techno-economic design, optimized by multi-objective particle swarm optimization technique is presented for the grid-tied GES linked to a small hamlet in the north of Egypt. The multi-objective function introduced in this work includes three objective functions which are, the Loss of Power Supply Probability (LPSP), the Cost of Energy (COE), and the System Surplus Energy Rates (SSER) considering the grid availability. The grid availability (GA) of 100% was considered as a base case and it was reduced to 70% with a step of 5%. The simulation consequences had cleared that the lowest and largest percentage values of SSER were obtained at GA of 85 %, and 70 % respectively. When the value of SSER equal to 0.33%, the system design for solving the grid unavailability consists of 12 PVs, one WT, and 1420 batteries with COE of 0.145$/kWh and TNPC of 3,699,800 ($).

1 April 2019 in Energy Procedia
Verified
Journal Article
Open access
Mohamed MosaadMohamed Mosaad
Mohamed Mosaad
MEM. Osama Abed El-Raouf
M. Osama Abed El-Raouf
MAMahmoud A. Al-Ahmar
Mahmoud A. Al-Ahmar
FBFahd A. Banakher
Fahd A. Banakher

9 February 2021 in IEEE Access
Verified
Journal Article
Open access
Mohamed MosaadMohamed Mosaad
Mohamed Mosaad
HRHaitham S. Ramadan
Haitham S. Ramadan
MAMansour Abdullah Aljohani
Mansour Abdullah Aljohani
MEMohamed F. El-Naggar
Mohamed F. El-Naggar
Sherif GhoneimSherif Ghoneim
Sherif Ghoneim
Connecting different renewable energy sources (RESs) to the electrical grids is presently being urged to fulfill the enormous need for electric power and to decrease traditional sources' ecological related issues, the so-called hybrid systems. Unfortunately, these hybrid systems suffer from the possible negative environmental impacts of the wind gusts in wind energy conversion systems (WECSs) that may degrade the overall system performance. Additionally, various severe faults may disconnect some RESs from the hybrid system, like three-phase faults. In this paper, the static synchronous compensator (STATCOM) is considered for both improving the performance of a hybrid system, contains WECS and photovoltaics (PVs) against wind gusts and maintaining the continuous operations of RESs during three-phase fault occur at the point of common coupling (PCC) between the RESs and the grid. The STATCOM is stimulated by two PI controllers regulating the reactive power flow between the STATCOM and the hybrid system at PCC and, consequently, regulating the voltage at PCC. A metaheuristic optimizer optimally schedules these two PI controllers based on whale optimization algorithm (WOA). The impartial comparison between the WOA dynamic performance and the particle swarm optimization as another optimization algorithm verifies the efficiency of the WOA for the near-optimal gain scheduling of the PI controller gains.

28 August 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Ahmed Abu-SiadaAhmed Abu-Siada
Ahmed Abu-Siada
Mohamed MosaadMohamed Mosaad
Mohamed Mosaad
DKDo Won Kim
Do Won Kim
MEMOHAMED ELNAGGAR
MOHAMED ELNAGGAR
Frequency response analysis (FRA) has become a widely accepted technique by worldwide utilities to detect winding and core deformations within power transformers. The main drawback of this technique is its reliance on the personnel level of expertise more than standard or automated codes. To establish reliable FRA interpretation codes, accurate high frequency transformer model that can emulate the frequency characteristics of real transformers in a wide frequency range is essential. The model can be used to investigate the impact of various winding and core deformations on the transformer FRA signature. The transformer equivalent high frequency electric circuit parameters can be calculated based on design data, which are rarely available, especially for old transformers. As such, this paper presents an artificial intelligence technique to estimate these parameters from the transformer FRA signature. The robustness of the proposed technique is assessed through its application on three, 3-phase power transformers of different ratings, sizes, and winding structures to estimate their high frequency electric circuit parameters during normal and fault conditions. Results show that the proposed technique can estimate equivalent circuit parameters with high accuracy and helps interpret the FRA signature based on the numerical changes of these parameters. The main advantage of this approach is the physical meaning of the model parameters facilitates reliable identification of various faults and hence aids in establishing reliable interpretation codes for transformer FRA signatures.

26 February 2018 in IET Electric Power Applications
Verified
Journal Article
Open access
PDF file
Mohamed MosaadMohamed Mosaad
Mohamed Mosaad
This article proposes a model reference adaptive control (MRAC) of static synchronous compensator (STATCOM) for enhancing the integration of driven wind turbine‐based self‐excited induction generator (SEIG) into electrical grids. An MRAC‐based Massachusetts Institute of Technology adaptive mechanism is utilised to control the reactive power flow of grid‐integrated SEIG. The voltage‐source inverter sinusoidal pulse width modulation of the STATCOM is used to overcome the abnormal operating conditions in the wind energy conversion system. This accordingly increases the low‐voltage ride through (LVRT) capability. The abnormal operating conditions are faults occurring at the point of common coupling between the generator and the grid. The proposed MRAC is compared to proportional‐integral (PI) controllers tuned by genetic algorithm (GA). To evaluate the proposed control of STATCOM for enhancing grid‐integrated SEIG, a part of the Egyptian 220 kV network integrated with Zafarana Wind Energy System is used. The results provide evidence of an efficient and robust proposed adaptive control performance rather than static PI controller whose parameters tuned by GA in the voltage, currents, and wind generator speed responses. Moreover, the proposed controller increases the capability of continuous operation of the wind turbines under different abnormal operating conditions and also increases the LVRT capability.