Using a solid-state reaction strategy, nominal Li3TiO3F oxyfluorides ceramics were fabricated, and its sintering behavior, microstructure, phase assemblages, as well as microwave dielectric performances were all investigated. The main phase of Li3TiO3F with cubic structures accompanied with small amounts of the LiF or Li2TiO3 secondary phase was identified by XRD analysis. SEM analysis showed that a uniform and dense microstructure was obtained for 750 °C-sintered samples. The dielectric constant (εr) and quality factor (Q × f) were found to be strongly correlated with porosity and grain size distribution, whereas the temperature coefficient of resonance frequency (τf) was mainly dominated by the phase assemblages. In particular, the 750 °C-sintered Li3TiO3F samples exhibited good microwave dielectric performances: εr = 18, Q × f = 57,300 GHz (under 9.2 GHz), τf = −43.0 ppm/°C.
Bilayer zirconia restoration is one of the most commonly used restorations in dental practice, but the high frequency of the cohesive/adhesive fracture of veneered porcelain is still a problem. This paper focuses on the development of nanostructured glass-zirconia to improve the interface stability of dental zirconia substrate and veneered porcelain. A novel SiO2-Li2O-Al2O3 (SLA) glass was prepared and infiltrated into the surface of fully sintered dental zirconia to obtain nanostructured glass-zirconia structure. The prepared glass-zirconia was analyzed with scanning electron microscopes (SEM), energy dispersive spectroscopy (EDS) and X-ray diffraction spectroscopy (XRD). The wettability, roughness and 3D morphology of zirconia were altered, and shear bonding strength (SBS) test demonstrated almost double increase in SBS values of the nanostructured glass-zirconia structure. The failure modes and microstructure characteristics also verified the improved interfacial stability. This investigation provides a promising method for enhancing the structural stability of bilayer zirconia restorations.
Background: Wear resistance affects dental ceramics longevity and the functions of the opposing teeth. However, data for the effect of aqueous environment on wear resistance of dental ceramics are lacking. This study evaluated the effect of aqueous environment on wear resistance of typical dental glass–ceramics. Methods: Disk specimens were prepared from lithium disilicate glass–ceramics (LD) and leucite reinforced glass–ceramics (LEU). The disk specimens paired with steatite antagonists were tested in a pin-on-disk tribometer under both wet and dry conditions with 10 N up to 500,000 wear cycles. The wear analysis of glass–ceramics was performed using a 3D profilometer after 100,000, 300,000 and 500,000 wear cycles. Wear morphologies were analyzed by employing scanning electron microscopy (SEM). The crystalline compositions of specimens stored in a dry environment and subsequently immersed in distilled water for 40 h were separately determined using X-ray diffraction (XRD). The chemical states of the wear surfaces for LD were analyzed by X-ray photoelectron spectroscopy (XPS). The data analysis and multiple pair-wise comparisons of means were performed by using one-way analysis of variance (ANOVA) and Tukey’s post-hoc test. Results: LEU in a wet environment exhibited less wear volume loss than that in a dry environment (p < 0.05). The volume loss of LD in a wet environment was higher than that in a dry environment (p < 0.05). The wear volumes of steatite antagonists paired with two glass–ceramics under dry conditions were higher than under wet conditions. Conclusions: XPS spectra of LD under wet conditions indicated that high wear loss might result from the effect of stress corrosion by water and reaction of water with the ionic-covalent bonds at the crack tip. XPS spectra and SEM images of LD under dry conditions showed a possible formation of tribofilm. Within the limitations of this in vitro study, water was wear-friendly to LEU and all opposing steatites but aggravated wear for LD.