Stephen John Ferguson

Prof. Dr. Stephen John Ferguson

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2016 in The Journal of Nutritional Biochemistry
Verified
Journal Article
Closed access
OKOlga Krupkova
Olga Krupkova
SFStephen John Ferguson
Stephen John Ferguson
Karin Wuertz-KozakKarin Wuertz-Kozak
Karin Wuertz-Kozak

10 August 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Paul F EganPaul F Egan
Paul F Egan
VGVeronica C Gonella
Veronica C Gonella
MEMax Engensperger
Max Engensperger
SFStephen John Ferguson
Stephen John Ferguson
KSKristina Shea
Kristina Shea
Tissue scaffolds provide structural support while facilitating tissue growth, but are challenging to design due to diverse property trade-offs. Here, a computational approach was developed for modeling scaffolds with lattice structures of eight different topologies and assessing properties relevant to bone tissue engineering applications. Evaluated properties include porosity, pore size, surface-volume ratio, elastic modulus, shear modulus, and permeability. Lattice topologies were generated by patterning beam-based unit cells, with design parameters for beam diameter and unit cell length. Finite element simulations were conducted for each topology and quantified how elastic modulus and shear modulus scale with porosity, and how permeability scales with porosity cubed over surface-volume ratio squared. Lattices were compared with controlled properties related to porosity and pore size. Relative comparisons suggest that lattice topology leads to specializations in achievable properties. For instance, Cube topologies tend to have high elastic and low shear moduli while Octet topologies have high shear moduli and surface-volume ratios but low permeability. The developed method was utilized to analyze property trade-offs as beam diameter was altered for a given topology, and used to prototype a 3D printed lattice embedded in an interbody cage for spinal fusion treatments. Findings provide a basis for modeling and understanding relative differences among beam-based lattices designed to facilitate bone tissue growth.

1 April 2016 in Journal of Biomechanics
Verified
Journal Article
Closed access
DIDominika Ignasiak
Dominika Ignasiak
SDSebastian Dendorfer
Sebastian Dendorfer
SFStephen John Ferguson
Stephen John Ferguson

Verified
Journal Article
Open access
PDF file
XDXiaoyu Du
Xiaoyu Du
SLSeunghun S. Lee
Seunghun S. Lee
Gurdial BluganGurdial Blugan
Gurdial Blugan
SFStephen John Ferguson
Stephen John Ferguson
Silicon nitride possesses a variety of excellent properties that can be specifically designed and manufactured for different medical applications. On the one hand, silicon nitride is known to have good mechanical properties, such as high strength and fracture toughness. On the other hand, the uniqueness of the osteogenic/antibacterial dualism of silicon nitride makes it a favorable bioceramic for implants. The surface of silicon nitride can simultaneously inhibit the proliferation of bacteria while supporting the physiological activities of eukaryotic cells and promoting the healing of bone tissue. There are hardly any biomaterials that possess all these properties concurrently. Although silicon nitride has been intensively studied as a biomedical material for years, there is a paucity of comprehensive data on its properties and medical applications. To provide a comprehensive understanding of this potential cornerstone material of the medical field, this review presents scientific and technical data on silicon nitride, including its mechanical properties, osteogenic behavior, and antibacterial capabilities. In addition, this paper highlights the current and potential medical use of silicon nitride and explains the bottlenecks that need to be addressed, as well as possible solutions.

8 March 2012 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
MPMichael Plecko
Michael Plecko
CSChristine Sievert
Christine Sievert
DADaniel Andermatt
Daniel Andermatt
RFRobert Frigg
Robert Frigg
PKPeter WM Kronen
Peter WM Kronen
BRBrigitte von Rechenberg
Brigitte von Rechenberg
Background: In the present study, 4 different metallic implant materials, either partly coated or polished, were tested for their osseointegration and biocompatibility in a pelvic implantation model in sheep.Methods: Materials to be evaluated were: Cobalt-Chrome (CC), Cobalt-Chrome/Titanium coating (CCTC), Cobalt-Chrome/Zirconium/Titanium coating (CCZTC), Pure Titanium Standard (PTST), Steel, TAN Standard (TANST) and TAN new finish (TANNEW). Surgery was performed on 7 sheep, with 18 implants per sheep, for a total of 63 implants. After 8 weeks, the specimens were harvested and evaluated macroscopically, radiologically, biomechanically (removal torque), histomorphometrically and histologically.Results: Cobalt-Chrome screws showed significantly (p = 0.031) lower removal torque values than pure titanium screws and also a tendency towards lower values compared to the other materials, except for steel. Steel screws showed no significant differences, in comparison to cobalt-chrome and TANST, however also a trend towards lower torque values than the remaining materials. The results of the fluorescence sections agreed with those of the biomechanical test. Histomorphometrically, there were no significant differences of bone area between the groups. The BIC (bone-to-implant-contact), used for the assessment of the osseointegration, was significantly lower for cobalt-chrome, compared to steel (p = 0.001). Steel again showed a lower ratio (p = 0.0001) compared to the other materials.Conclusion: This study demonstrated that cobalt-chrome and steel show less osseointegration than the other metals and metal-alloys. However, osseointegration of cobalt-chrome was improved by zirconium and/or titanium based coatings (CCTC, TANST, TAN, TANNEW) being similar as pure titanium in their osseointegrative behavior.

20 January 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SBSarah Broeckx
Sarah Broeckx
MZMarieke Zimmerman
Marieke Zimmerman
SCSara Crocetti
Sara Crocetti
MSMarc Suls
Marc Suls
TMTom Mariën
Tom Mariën
JSJan H. Spaas
Jan H. Spaas
Degenerative joint disease (DJD) is a major cause of reduced athletic function and retirement in equine performers. For this reason, regenerative therapies for DJD have gained increasing interest. Platelet-rich plasma (PRP) and mesenchymal stem cells (MSCs) were isolated from a 6-year-old donor horse. MSCs were either used in their native state or after chondrogenic induction. In an initial study, 20 horses with naturally occurring DJD in the fetlock joint were divided in 4 groups and injected with the following: 1) PRP; 2) MSCs; 3) MSCs and PRP; or 4) chondrogenic induced MSCs and PRP. The horses were then evaluated by means of a clinical scoring system after 6 weeks (T1), 12 weeks (T2), 6 months (T3) and 12 months (T4) post injection. In a second study, 30 horses with the same medical background were randomly assigned to one of the two combination therapies and evaluated at T1. The protein expression profile of native MSCs was found to be negative for major histocompatibility (MHC) II and p63, low in MHC I and positive for Ki67, collagen type II (Col II) and Vimentin. Chondrogenic induction resulted in increased mRNA expression of aggrecan, Col II and cartilage oligomeric matrix protein (COMP) as well as in increased protein expression of p63 and glycosaminoglycan, but in decreased protein expression of Ki67. The combined use of PRP and MSCs significantly improved the functionality and sustainability of damaged joints from 6 weeks until 12 months after treatment, compared to PRP treatment alone. The highest short-term clinical evolution scores were obtained with chondrogenic induced MSCs and PRP. This study reports successful in vitro chondrogenic induction of equine MSCs. In vivo application of (induced) MSCs together with PRP in horses suffering from DJD in the fetlock joint resulted in a significant clinical improvement until 12 months after treatment.