Paul F Egan

Prof. Paul F Egan

Department of Mechanical and Aerospace Engineering, Texas Tech University, Lubbock, Texas, USA
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2021 in Polymers
Verified
Journal Article
Open access
PDF file
AAAmit Arefin
Amit Arefin
NKNava Khatri
Nava Khatri
NKNitin Kulkarni
Nitin Kulkarni
Paul F EganPaul F Egan
Paul F Egan
Polymer 3D printing is an emerging technology with recent research translating towards increased use in industry, particularly in medical fields. Polymer printing is advantageous because it enables printing low-cost functional parts with diverse properties and capabilities. Here, we provide a review of recent research advances for polymer 3D printing by investigating research related to materials, processes, and design strategies for medical applications. Research in materials has led to the development of polymers with advantageous characteristics for mechanics and biocompatibility, with tuning of mechanical properties achieved by altering printing process parameters. Suitable polymer printing processes include extrusion, resin, and powder 3D printing, which enable directed material deposition for the design of advantageous and customized architectures. Design strategies, such as hierarchical distribution of materials, enable balancing of conflicting properties, such as mechanical and biological needs for tissue scaffolds. Further medical applications reviewed include safety equipment, dental implants, and drug delivery systems, with findings suggesting a need for improved design methods to navigate the complex decision space enabled by 3D printing. Further research across these areas will lead to continued improvement of 3D-printed design performance that is essential for advancing frontiers across engineering and medicine.

6 July 2015 in Nature Communications
Verified
Journal Article
Open access
PDF file
Paul F EganPaul F Egan
Paul F Egan
RSRobert Sinko
Robert Sinko
PLPhilip R. LeDuc
Philip R. LeDuc
SKSinan Keten
Sinan Keten
Natural systems frequently exploit intricate multiscale and multiphasic structures to achieve functionalities beyond those of man-made systems. Although understanding the chemical make-up of these systems is essential, the passive and active mechanics within biological systems are crucial when considering the many natural systems that achieve advanced properties, such as high strength-to-weight ratios and stimuli-responsive adaptability. Discovering how and why biological systems attain these desirable mechanical functionalities often reveals principles that inform new synthetic designs based on biological systems. Such approaches have traditionally found success in medical applications, and are now informing breakthroughs in diverse frontiers of science and engineering.

10 August 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Paul F EganPaul F Egan
Paul F Egan
VGVeronica C Gonella
Veronica C Gonella
MEMax Engensperger
Max Engensperger
SFStephen John Ferguson
Stephen John Ferguson
KSKristina Shea
Kristina Shea
Tissue scaffolds provide structural support while facilitating tissue growth, but are challenging to design due to diverse property trade-offs. Here, a computational approach was developed for modeling scaffolds with lattice structures of eight different topologies and assessing properties relevant to bone tissue engineering applications. Evaluated properties include porosity, pore size, surface-volume ratio, elastic modulus, shear modulus, and permeability. Lattice topologies were generated by patterning beam-based unit cells, with design parameters for beam diameter and unit cell length. Finite element simulations were conducted for each topology and quantified how elastic modulus and shear modulus scale with porosity, and how permeability scales with porosity cubed over surface-volume ratio squared. Lattices were compared with controlled properties related to porosity and pore size. Relative comparisons suggest that lattice topology leads to specializations in achievable properties. For instance, Cube topologies tend to have high elastic and low shear moduli while Octet topologies have high shear moduli and surface-volume ratios but low permeability. The developed method was utilized to analyze property trade-offs as beam diameter was altered for a given topology, and used to prototype a 3D printed lattice embedded in an interbody cage for spinal fusion treatments. Findings provide a basis for modeling and understanding relative differences among beam-based lattices designed to facilitate bone tissue growth.

24 July 2019 in Materials
Verified
Journal Article
Open access
PDF file
Paul F EganPaul F Egan
Paul F Egan
Emerging 3D printing technologies are enabling the fabrication of complex scaffold structures for diverse medical applications. 3D printing allows controlled material placement for configuring porous tissue scaffolds with tailored properties for desired mechanical stiffness, nutrient transport, and biological growth. However, tuning tissue scaffold functionality requires navigation of a complex design space with numerous trade-offs that require multidisciplinary assessment. Integrated design approaches that encourage iteration and consideration of diverse processes including design configuration, material selection, and simulation models provide a basis for improving design performance. In this review, recent advances in design, fabrication, and assessment of 3D printed tissue scaffolds are investigated with a focus on bone tissue engineering. Bone healing and fusion are examples that demonstrate the needs of integrated design approaches in leveraging new materials and 3D printing processes for specified clinical applications. Current challenges for integrated design are outlined and emphasize directions where new research may lead to significant improvements in personalized medicine and emerging areas in healthcare.

12 October 2015 in Journal of Mechanical Design
Verified
Journal Article
Closed access
PDF file
TSTino Stanković
Tino Stanković
JMJochen Mueller
Jochen Mueller
Paul F EganPaul F Egan
Paul F Egan
KSKristina Shea
Kristina Shea

9 January 2008 in Physical Review B
Verified
Journal Article
Closed access
PDF file
VZV. S. Zapf
V. S. Zapf
VCV. F. Correa
V. F. Correa
PSP. Sengupta
P. Sengupta
CBC. D. Batista
C. D. Batista
MTM. Tsukamoto
M. Tsukamoto
APA. Paduan-Filho
A. Paduan-Filho
We demonstrate that the short-range spin correlator ⟨Si⋅Sj⟩, a fundamental measure of the interaction between adjacent spins, can be directly measured in certain insulating magnets. We present magnetostriction data for the insulating organic compound NiCl2−4SC(NH2)2, and show that the magnetostriction as a function of field is proportional to the dominant short-range spin correlator. Furthermore, the constant of proportionality between the magnetostriction and the spin correlator gives information about the spin-lattice interaction. Combining these results with the measured Young’s modulus, we are able to extract dJ∕dz, the dependence of the superexchange constant J on the Ni interionic distance z.