Burak Hunuk

Dr. Burak Hunuk

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2015 in Heart Rhythm
Verified
Journal Article
Closed access
GCGiuseppe Ciconte
Giuseppe Ciconte
Carlo de AsmundisCarlo de Asmundis
Carlo de Asmundis
JSJuan Sieira
Juan Sieira
GCGiulio Conte
Giulio Conte
GGGiacomo Di Giovanni
Giacomo Di Giovanni
GCGian-Battista Chierchia
Gian-Battista Chierchia

1 December 2015 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
PDF file
GCGiuseppe Ciconte
Giuseppe Ciconte
Giacomo MugnaiGiacomo Mugnai
Giacomo Mugnai
JSJuan Sieira
Juan Sieira
VVVedran Velagić
Vedran Velagić
YSYukio Saitoh
Yukio Saitoh
GCGian-Battista Chierchia
Gian-Battista Chierchia
Background—: The second-generation cryoballoon is effective in achieving acute pulmonary vein isolation (PVI) and favorable clinical outcome. To date, no data are available on factors affecting late PV reconnection after second-generation cryoballoon ablation. Methods and Results—: A total of 29 consecutive patients (25 male, 86.2%; mean age 57.8±13.8 years) underwent a repeat procedure, after a mean 11.6±4.5 months (range, 3.5–19.7 months), after index ablation using the 28-mm second-generation cryoballoon. All repeat ablations were performed using a 3-dimensional electroanatomical mapping system. Among all 115 PVs, including 1 left common ostiums (LCOs), 25 (21.7%) showed a PV reconnection in 20 patients (1.25 per patient). Persistent PVI could be documented in 90 of 115 PVs (78.2%). In 9 of 29 patients (31%), all PVs were electrically isolated. In the multivariable analysis, time to PVI ( P =0.03) and failure to achieve −40°C within 60 s ( P =0.05) independently predicted late PV reconnection. At receiver-operator curve analysis, time to PVI <60 s identified the absence of PV reconduction (sensitivity, 86.7%; specificity, 86.2%; positive predictive value, 59.1%; and negative predictive value, 96.4%; area under the curve, 0.85; confidence interval, 0.73–0.97; P <0.001). Conclusions—: The rate of late PV reconnection after second-generation cryoballoon ablation is low (1.25 PVs/patient). Faster time to isolation and achievement of −40°C within 60 s independently predict durable PVI. In addition, 60-s cut-off for time to PVI indicates persistent isolation with 96.4% negative predictive value. These parameters might guide the operator whether to perform further applications to ensure a long-lasting PVI.

12 January 2015 in EP Europace
Verified
Journal Article
Open access
PDF file
GCGiuseppe Ciconte
Giuseppe Ciconte
GBGiannis Baltogiannis
Giannis Baltogiannis
Carlo de AsmundisCarlo de Asmundis
Carlo de Asmundis
JSJuan Sieira
Juan Sieira
GCGiulio Conte
Giulio Conte
PBPedro Brugada
Pedro Brugada
To assess the 1 year efficacy of pulmonary vein isolation (PVI) as index procedure for persistent atrial fibrillation (PersAF) comparing conventional radiofrequency irrigated-tip catheter ablation (RFCA) using contact-force technology and ablation using the second-generation cryoballoon (CB-AdvA). One hundred consecutive patients (74 male, 74%; mean age 62.4 ± 9.6 years) with drug-refractory PersAF undergoing PVI using RFCA and CB-AdvA were enrolled. Follow-up was based on outpatient clinic visits including Holter-electrocardiograms. Recurrence of atrial tachyarrhythmias (ATas) was defined as a symptomatic or documented episode >30 s. Among 100 patients, 50 underwent RFCA whereas 50 CB-AdvA. Mean procedure and fluoroscopy times were 90.5 ± 41.7 vs. 140.2 ± 46.9 min and 14.5 ± 6.6 vs. 19.8 ± 6.8 min in the CB-Adv and in the RFCA group, respectively (P < 0.01). At 1 year follow-up, after a 3 months blanking period (BP), freedom from ATas off-drugs after a single procedure was 60% (28/50 patients) in the CB-Adv and 56% (27/50 patients) in the RFCA group (P = 0.71). Multivariate analysis demonstrated that PersAF duration (P = 0.01) and relapses during BP (P = 0.02) were independent predictors of ATa recurrences following the index procedure. Freedom from ATas following PersAF ablation with RFCA and CB-Adv is comparable at 1 year follow-up after a single procedure. Ablation with the CB-Adv is associated with shorter procedure time and radiation exposure as compared with RFCA. Atrial tachyarrhythmias occurrence during BP and longer time of PersAF seem to be significant predictors of arrhythmia recurrences after the index procedure.

7 October 2015 in EP Europace
Verified
Journal Article
Closed access
PDF file
GCGiuseppe Ciconte
Giuseppe Ciconte
VVVedran Velagić
Vedran Velagić
Giacomo MugnaiGiacomo Mugnai
Giacomo Mugnai
YSYukio Saitoh
Yukio Saitoh
GIGhazala Irfan
Ghazala Irfan
GCGian-Battista Chierchia
Gian-Battista Chierchia
Aims To assess the incidence of late pulmonary vein (PV) reconnection following index PV isolation (PVI) procedure initially achieved with radiofrequency contact-force catheter ablation (CFCA) and second-generation cryoballoon ablation (CB-AdvA). Methods and results A total of 56 consecutive patients (41 male, 73.2%; mean age 60.8 ± 11.8 years) underwent a repeat ablation because of recurrent atrial tachyarrhythmias (ATas) after index PVI achieved with CFCA (30 patients) or CB-AdvA (26 patients). All repeat procedures were performed by the means of CFCA. In the CFCA group, among 119 PVs, 43 (36.1%) showed conduction gaps in 24 patients (1.8 per patient), whereas in the CB-AdvA group among 103 veins, 21 (20.4%) showed a PV reconnection in 18 patients (1.2 per patient) (P = 0.01). The left superior pulmonary vein was less frequently reconnected following CB-AdvA when compared with CFCA (2/25, 8% vs. 11/29, 37.9%; P = 0.01). In the CFCA group, the mean CF per-vein was lower in reconnecting veins when compared with those persistently isolated (10.9 ± 2.7 vs. 18.6 ± 3.1 g; P < 0.001). In the CB-AdvA group, late PV reconnection was associated with warmer nadir temperature (−48.9 ± 5.1 vs. −51.2 ± 4.7°C; P = 0.05) and longer time-to-isolation (71.1 ± 20.2 vs. 50.2 ± 32.9 s; P = 0.03). Conclusion The rate of late PV reconnection is significantly lower following CB-AdvA when compared with CFCA as index procedure. Lower CF values and warmer nadir temperature with longer time to effect were more frequently associated with PV reconnections in the setting of CFCA and CB-AdvA.

1 April 2016 in Heart Rhythm
Verified
Journal Article
Closed access
Giacomo MugnaiGiacomo Mugnai
Giacomo Mugnai
Carlo de AsmundisCarlo de Asmundis
Carlo de Asmundis
BHBurak Hunuk
Burak Hunuk
ESErwin Ströker
Erwin Ströker
VVVedran Velagic
Vedran Velagic
GCGian-Battista Chierchia
Gian-Battista Chierchia

16 May 2016 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
GCGiuseppe Ciconte
Giuseppe Ciconte
JSJuan Sieira‐Moret
Juan Sieira‐Moret
EHEbru Hacioglu
Ebru Hacioglu
Giacomo MugnaiGiacomo Mugnai
Giacomo Mugnai
GGGiacomo DI Giovanni
Giacomo DI Giovanni
GCGian‐Battista Chierchia
Gian‐Battista Chierchia