Kristofer Hägg

Kristofer Hägg

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
Alfredo Gonzalez-PerezAlfredo Gonzalez-Perez
Alfredo Gonzalez-Perez
KHKristofer Hägg
Kristofer Hägg
FDFabrice Duteil
Fabrice Duteil
Understanding the character of natural organic matter (NOM) and assessing its impact on water quality is paramount for managers of catchments and water utilities. For drinking-water producers, NOM affects disinfectant demand and the formation of by-products which can have adverse health effects. NOM content in raw waters also has an impact on water treatment processes by increasing required coagulant dosages, reducing the effectiveness of adsorption processes and fouling membrane systems. This study investigated the effects of calcium chloride (CaCl2) as a co-coagulant in Al3+ and Fe3+ assisted coagulation, flocculation and sedimentation processes for NOM-removal from raw water collected from Lake Bolmen, in southern Sweden. Jar tests were conducted at Ringsjö Water Works (WW), a surface water treatment plant (WTP), to investigate the potential reduction in primary coagulants aluminum sulphate (Al2(SO4)3) and ferric chloride (FeCl3). This work shows that CaCl2 can, in certain situations, reduce the need for primary coagulants, which would reduce the environmental impact and costs associated with primary coagulant consumption.

12 February 2021 in Environmental Science: Water Research & Technology
Verified
Journal Article
Open access
PDF file
KHKristofer Hägg
Kristofer Hägg
JLJing Li
Jing Li
MHMasoumeh Heibati
Masoumeh Heibati
KMKathleen R. Murphy
Kathleen R. Murphy
CPCatherine J. Paul
Catherine J. Paul
Kenneth M. PerssonKenneth M. Persson
Kenneth M. Persson
The capacity of an artificial recharge field to alter organic matter and the bacterial flora of surface water was assessed by following changes in bacterial communities and composition of natural organic matter (NOM) over the first meter of infiltration depth. The sampling strategy applied in this study ensured that water samples consisted only of infiltrated water, excluding natural groundwater. Water was sampled at 50 and 100 cm below the surface of an infiltration basin divided into two halves; one side was dried and frozen and one was infiltrating water during the winter period prior to the sampling period. Bacterial cell counts, proportions of intact cells and community fingerprints were determined by flow cytometry, and NOM was characterized using total organic carbon (TOC), UV254 nm-absorbance (UVA) and fluorescence spectroscopy. Around 40% of the NOM was removed after only 50 cm. Protein-like components were reduced to a larger extent (45–50%) than the humic-like components (25%), suggesting removal of mostly biodegradable fractions of NOM. After only 50 cm of infiltration, about 99% total cell count (TCC) was removed. The flow cytometric data revealed that the bacterial communities collected after infiltration from the basin area that had been dried and frozen were more similar to those in the raw water. This suggests that drying and freezing the basin negatively impacted its treatment capacity. The results from this study highlight the importance of a well-developed biofilm and unsaturated zone for artificial recharge.

5 May 2020 in Water Supply
Verified
Journal Article
Open access
PDF file
KHKristofer Hägg
Kristofer Hägg
TPT. Persson
T. Persson
OSO. Söderman
O. Söderman
KPK. M. Persson
K. M. Persson
The natural organic matter (NOM) and color content of surface waters are increasingly becoming an issue for artificial groundwater recharge plants. Water from Lake Bolmen, in southern Sweden, had in 2017 an annual average NOM and color content of 8.6 mg/L total organic carbon (TOC) and 57 mg Pt/L respectively, and values ranging from 7.8 to 9.6 mg/L TOC and 50–70 mg Pt/L. Since water from Lake Bolmen will be used at Vomb Water Works, an artificial groundwater recharge plant, the high NOM-content of Lake Bolmen must be reduced prior to aquifer recharge. From experiences of full-scale operations of chemical flocculation, lamella sedimentation and rapid sand filtration using ferric chloride, three different pre-treatment methods were proposed; conventional precipitation, stand-alone direct precipitation before ultrafiltration (UF), and conventional precipitation with ultrafiltration after lamella sedimentation. In this study, a hollow fiber membrane (MWCO of 150 kDa) was used in different configurations during a 15 months pilot trial. The results showed the possibility to reduce NOM equal to conventional precipitation when a stable net-flux of 40 and 70 L/(m2· h) was used for direct precipitation before UF and conventional precipitation with UF, respectively. This paper presents these treatment methods and evaluates their viability as full-scale treatment steps.

9 February 2024 in Water Practice & Technology
Verified
Journal Article
Open access
PDF file
KHKristofer Hägg
Kristofer Hägg
TPTobias Persson
Tobias Persson
Common methods for treating surface waters involve chemical flocculation, for which a significant factor contributing to the total cost and climate impact is the consumption of chemicals, chiefly coagulants and pH-adjusting chemicals. The amount of chemicals required for treating surface waters and achieving suitable flocculation pH depends greatly on the alkalinity of the source water. This study investigates the viability of mixing two surface waters with different chemical properties with the aim of reducing the amount of chemicals used during chemical flocculation. Bench-scale experiments were carried out, and the results were compared with full-scale operations at a surface water treatment plant (WTP). The WTP uses ferric chloride as a coagulant, which effectively removes natural organic matter, but consumes large amounts of hydroxide to manage pH before and after flocculation. As an alternative process, this study tested the use of aluminum sulfate, polyaluminum chloride and ferric chloride at varying dosages in combination with different source water mixtures to achieve suitable flocculation pH. The results showed that pH-adjusting chemicals could be omitted by adding a small amount of high alkalinity surface water to the primary source water, thereby reducing costs and climate impact substantially.

24 September 2019 in Water
Verified
Journal Article
Open access
PDF file
JLJing Li
Jing Li
KHKristofer Hägg
Kristofer Hägg
Kenneth M. PerssonKenneth M. Persson
Kenneth M. Persson
Artificial groundwater recharge is commonly used for drinking water supply. The resulting water quality is highly dependent on the raw water quality. In many cases, pretreatment is required. Pretreatment improves the drinking water quality, although how and to what extent it affects the subsequent pond water quality and infiltration process, is still unknown. We evaluated two treatment systems by applying different pretreatment methods for raw water from a eutrophic and temperate lake. An artificial recharge pond was divided into two parts, where one received raw water, only filtered through a microscreen with 500 µm pores (control treatment), while the other part received pretreated lake water using chemical flocculation with polyaluminum chloride (PACl) combined with sand filtration, i.e., continuous contact filtration (contact filter treatment). Water quality factors such as cyanobacterial biomass, microcystin, as well as organic matter and nutrients were measured in both treatment processes. Microcystin condition was screened by an immunoassay and a few selected samples were examined by ultra-high-performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) which is a chemistry technique that combines the physical separation capabilities of liquid chromatography with the mass analysis capabilities of mass spectrometry. Results showed that cyanobacterial biomass and microcystin after the contact filter treatment were significantly different from the control treatment and also significantly different in the pond water. In addition, with contact filter treatment, total phosphorus (TP) and organic matter removal were significantly improved in the end water, TP was reduced by 96% (<20 µg/L) and the total organic carbon (TOC) was reduced by 66% instead of 55% (TOC content around 2.1 mg/L instead of 3.0 mg/L). This full-scale onsite experiment demonstrated effective pretreatment would benefit a more stable water quality system, with less variance and lower microcystin risk. From a broader drinking water management perspective, the presented method is promising for reducing cyanotoxin risk, as well as TP and TOC, which are all predicted to increase with global warming and extreme weather.

14 December 2018 in Water
Verified
Journal Article
Open access
PDF file
KHKristofer Hägg
Kristofer Hägg
MCMichael Cimbritz
Michael Cimbritz
Kenneth M. PerssonKenneth M. Persson
Kenneth M. Persson
Natural organic matter (NOM) is a growing concern for artificial recharge plants. In the future, it is predicted that warmer climates and more precipitation will cause higher NOM production in lakes and more NOM transport to lakes. This, coupled with increasing drinking water demand due to the population increase, is pushing operators of water treatment plants (WTPs) to find new ways to treat water. In this study, the possibility of reducing the organic load in infiltration basins through a compact pre-treatment technique utilizing microsieves, or disc filters, instead of bulky sedimentation basins and rapid sand filters after chemical flocculation to separate flocs, was investigated. The experiments were conducted using a laboratory-scale flocculator, bench-scale disc filters (10 µm and 40 µm), FeCl3, an anionic synthetic polymer, and water from Lake Vomb, a lake in southern Sweden. Raw water was flocculated using FeCl3 and the polymer, and the filtrated samples were analyzed by measuring UV–VIS absorbance, total organic carbon (TOC), and permeate volume. The results when using 10-µm and 40-µm disc filters demonstrate that it is possible to reduce NOM (by approximately 50%) and separate flocs from raw water. The experiments also highlight the importance of sufficient flocculation times and the use of appropriate polymer dosage to achieve higher permeate volumes and avoid residual polymers in the effluent. In this paper, the possibility of using this technique as a standalone treatment step or as a pre-treatment step in order to manage the aquifer recharge is demonstrated.