Laurent Baillet

Dr. Laurent Baillet

Centre National de la Recherche Scientifique (CNRS), Institut des Sciences de la Terre (ISterre), Université Grenoble Alpes, 38000 Grenoble, France

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 February 2021 in Surveys in Geophysics
Verified
Journal Article
Open access
PDF file
Chiara ColomberoChiara Colombero
Chiara Colombero
DJD. Jongmans
D. Jongmans
SFS. Fiolleau
S. Fiolleau
JVJ. Valentin
J. Valentin
LBLaurent Baillet
Laurent Baillet
GBG. Bièvre
G. Bièvre
Continuous ambient seismic monitoring of potentially unstable sites is increasingly attracting the attention of researchers for precursor recognition and early warning purposes. Twelve cases of long-term continuous noise monitoring have been reported in the literature between 2012 and 2020. Only in a few cases rupture was achieved and irreversible drops in resonance frequency values or shear wave velocity extracted from noise recordings were documented. On the other hand, all monitored sites showed clear reversible fluctuations of the seismic parameters on a daily and seasonal scale due to changes in external weather conditions (air temperature and precipitation). A quantitative comparison of these reversible modifications is used to gain insight into the mechanisms driving the site seismic response. Six possible mechanisms were identified, including three temperature-driven mechanisms (temperature control on fracture opening/closing, superficial stress conditions and bulk rigidity), one precipitation-driven mechanism (water infiltration effect) and two mechanisms sensitive to both temperature and precipitation (ice formation and clay behavior). The reversible variations in seismic parameters under the meteorological constraints are synthesized and compared to the irreversible changes observed prior to failure in different geological conditions.

26 July 2022 in Remote Sensing
Verified
Journal Article
Open access
PDF file
ACArthur Charléty
Arthur Charléty
MBMathieu Le Breton
Mathieu Le Breton
ELEric Larose
Eric Larose
LBLaurent Baillet
Laurent Baillet
Passive radio-frequency identification (RFID) was recently used to monitor landslide displacement at a high spatio-temporal resolution but only measured 1D displacement. This study demonstrates the tracking of 2D displacements, using an array of antennas connected to an RFID interrogator. Ten tags were deployed on a landslide for 12 months and 2D relative localization was performed using a phase-of-arrival approach. A period of landslide activity was monitored through RFID and displacements were confirmed by reference measurements. The tags showed displacements of up to 1.2 m over the monitored period. The centimeter-scale accuracy of the technique was confirmed experimentally and theoretically for horizontal localization by developing a measurement model that included antenna and tag positions, as well as multipath interference. This study confirms that 2D landslide displacement tracking with RFID is feasible at relatively low instrumental and maintenance cost.

27 December 2017 in IEEE Journal of Radio Frequency Identification
Verified
Journal Article
Closed access
MBMathieu Le Breton
Mathieu Le Breton
LBLaurent Baillet
Laurent Baillet
ELEric Larose
Eric Larose
EREtienne Rey
Etienne Rey
PBPhilippe Benech
Philippe Benech
FGFabrice Guyoton
Fabrice Guyoton
This paper investigates meteorological factors that affect the phase of radio-frequency identification (RFID) passive tags at 868 MHz, in outdoor conditions. The study identifies the effect of water on the tag and base antennas, the effect of temperature on the cables, tags, and base antenna, the effect of the tag support moisture, and the effect of atmospheric conditions on wave velocity. Combined, these effects could lead to over 8.1 radians phase drift over a year, in a typical environment. In a tag location tracking application, that would correspond to an error of 22 cm. This paper proposes techniques to correct these effects and to increase the phase stability. These techniques are applied to a new RFID system, which is tested in outdoor conditions, for five months. The new system improves the phase stability for rainy days, dry days, and long-term drift by a factor of 3, 12, and 5, respectively. After corrections, the long-term drift was reduced to below 0.05 radians per month, which corresponds to 1.5 millimeter per month.

2 July 2019 in Lubricants
Verified
Journal Article
Open access
PDF file
DTDAVIDE TONAZZI
DAVIDE TONAZZI
Francesco MassiFrancesco Massi
Francesco Massi
MSMario Salipante
Mario Salipante
LBLaurent Baillet
Laurent Baillet
YBYves Berthier
Yves Berthier
Modeling of frictional contact systems with high accuracy needs the knowledge of several contact parameters, which are mainly related to the local phenomena at the contact interfaces and affect the complex dynamics of mechanical systems in a prominent way. This work presents a newer approach for identifying reliable values of the normal contact stiffness between surfaces in contact, in both sliding and sticking conditions. The combination of experimental tests, on a dedicated set-up, with finite element modeling, allowed for an indirect determination of the normal contact stiffness. The stiffness was found to increase with increasing contact pressure and decreasing roughness, while the evolution of surface topography and third-body rheology affected the contact stiffness when sliding.

4 June 2021 in Geosciences
Verified
Journal Article
Open access
PDF file
PBPierre Bottelin
Pierre Bottelin
LBLaurent Baillet
Laurent Baillet
ACAurore Carrier
Aurore Carrier
ELEric Larose
Eric Larose
DJDenis Jongmans
Denis Jongmans
HCHéloïse Cadet
Héloïse Cadet
Ambient Vibration-Based Structural Health Monitoring (AVB–SHM) studies on prone-to-fall rock compartments have recently succeeded in detecting both pre-failure damaging processes and reinforcement provided by bolting. The current AVB–SHM instrumentation layout is yet generally an overkill, creating cost and power issues and sometimes requiring advanced signal processing techniques. In this article, we paved the way toward an innovative edge-computing approach tested on ambient vibration records made during the bolting of a ~760 m3 limestone rock column (Vercors, France). First, we established some guidelines for prone-to-fall rock column AVB–SHM by comparing several basic, computing-efficient, seismic parameters (i.e., Fast Fourier Transform, Horizontal to Vertical and Horizontal to Horizontal Spectral Ratios). All three parameters performed well in revealing the unstable compartment’s fundamental resonance frequency. HHSR appeared as the most consistent spectral estimator, succeeding in revealing both the fundamental and higher modes. Only the fundamental mode should be trustfully monitored with HVSR since higher peaks may be artifacts. Then, the first application of a novelty detection algorithm on an unstable rock column AVB–SHM case study showed the following: the feasibility of automatic removing the adverse thermomechanical fluctuations in column’s dynamic parameters based on machine learning, as well as the systematic detection of clear, permanent change in column’s dynamic behavior after grout injection and hardening around the bolts (i1 and i2). This implementation represents a significant workload reduction, compared to physical-based algorithms or numerical twin modeling, and shows better robustness with regard to instrumentation gaps. We believe that edge-computing monitoring systems combining basic seismic signal processing techniques and automatic detection algorithms could help facilitate AVB–SHM of remote natural structures such as prone-to-fall rock compartments.

10 July 2020 in Lubricants
Verified
Journal Article
Open access
PDF file
DNDorra Nouira
Dorra Nouira
DTDAVIDE TONAZZI
DAVIDE TONAZZI
AMAnissa Meziane
Anissa Meziane
LBLaurent Baillet
Laurent Baillet
Francesco MassiFrancesco Massi
Francesco Massi
Modelling interface interaction with wave propagation in a medium is a fundamental requirement for several types of application, such as structural diagnostic and quality control. In order to study the influence of a pressure-dependent interface stiffness on the nonlinear response of contact interfaces, two nonlinear contact laws are investigated. The study consists of a complementary numerical and experimental analysis of nonlinear vibrational responses due to the contact interface. The laws investigated here are based on an interface stiffness model, where the stiffness property is described as a nonlinear function of the nominal contact pressure. The results obtained by the proposed laws are compared with experimental results. The nonlinearity introduced by the interface is highlighted by analysing the second harmonic contribution and the vibrational time response. The analysis emphasizes the dependence of the system response, i.e., fundamental and second harmonic amplitudes and frequencies, on the contact parameters and in particular on contact stiffness. The study shows that the stiffness–pressure trend at lower pressures has a major effect on the nonlinear response of systems with contact interfaces.