Shengyu Yao

Shengyu Yao


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2021 in Biochemical and Biophysical Research Communications
Verified
Journal Article
Closed access
YXYiqing Xu
Yiqing Xu
WTWenzhi Tu
Wenzhi Tu
DSDi Sun
Di Sun
XCXuming Chen
Xuming Chen
YGYulong Ge
Yulong Ge
YLYong Liu
Yong Liu

9 May 2019 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
SYShengyu Yao
Shengyu Yao
YZYin Zhang
Yin Zhang
KNKe Nie
Ke Nie
BLBo Liu
Bo Liu
BHBruce Haffty
Bruce Haffty
NYNing J. Yue
Ning J. Yue
To investigate the setup uncertainties and to establish an optimal imaging schedule for the prone-positioned whole breast radiotherapy. Twenty prone-positioned breast patients treated with tangential fields from 2015 to 2017 were retrospectively enrolled in this study. The prescription dose for the whole breast treatment was 266 cGy × 16 for all of the patients and the treatments were delivered with the SSD setup technique. At every fraction of treatment, patient was firstly set up based on the body localization tattoos. MV portal imaging was then taken to confirm the setup; if discrepancy (> 3 mm) was found between the portal images and corresponding plan images, the patient positioning was adjusted accordingly with couch movement. Based on the information acquired from the daily tattoo and portal imaging setup, three sets of data, named as weekly imaging guidance (WIG), no daily imaging guidance (NIG), and initial 3 days then weekly imaging guidance (3 + WIG) were sampled, constructed, and analyzed in reference to the benchmark of the daily imaging guidance (DIG). We compared the setup uncertainties, target coverage (D95, Dmax), V5 of the ipsilateral lung, the mean dose of heart, the mean and max dose of the left-anterior-descending coronary artery (LAD) among the 4 imaging guidance (IG) schedules. Relative to the daily imaging guidance (IG) benchmark, the NIG schedule led to the largest residual setup uncertainties; the uncertainties were similar for the WIG and 3 + WIG schedules. Little variations were observed for D95 of the target among NIG, DIG and WIG. The target Dmax also exhibited little changes among all the IG schedules. While V5 of the ipsilateral lung changed very little among all 4 schedules, the percent change of the mean heart dose was more pronounced; but its absolute values were still within the tolerance. However, for the left-sided breast patients, the LAD dose could be significantly impacted by the imaging schedules and could potentially exceed its tolerance criteria in some patients if NIG, WIG and 3 + WIG schedules were used. For left-side whole breast treatment in the prone position using the SSD treatment technique, the daily imaging guidance can ensure dosimetric coverage of the target as well as preventing critical organs, especially LAD, from receiving unacceptable levels of dose. For right-sided whole breast treatment in the prone position, the weekly imaging setup guidance appears to be the optimal choice.

1 January 2019 in Technology in Cancer Research & Treatment
Verified
Journal Article
Open access
PDF file
SYShengyu Yao
Shengyu Yao
YZYin Zhang
Yin Zhang
TCTingfeng Chen
Tingfeng Chen
GZGuoqi Zhao
Guoqi Zhao
ZHZhekai Hu
Zhekai Hu
YLYong Liu
Yong Liu
Purpose: This article compares the dosimetric differences between jaw tracking and no jaw tracking technique in static intensity-modulated radiation therapy plans of large and small tumors. Methods: Eight plans with large tumor (nasopharyngeal carcinoma, volume range: 510.9 to 768.0 cm3) and 8 plans with small tumor (single brain metastasis, volume range: 5.3 to 9.9 cm3) treated with jaw tracking on Varian EDGE LINAC were chosen and recalculated with no jaw tracking to study the dosimetric differences. We compared the differences of organ-at-risk doses (Dmax, Dmean), monitor units, and γ passing rate of plan verification (3mm/3%, threshold 10%; 2mm/2%, threshold 10%) between the 2 techniques. Results: The organ-at-risk doses of nasopharyngeal carcinoma cases having jaw tracking are all less than those with no jaw tracking. The Dmax and Dmean of organ-at-risks reduced 0.61% to 17.65% and 2.17% to 19.32%, P < .05, respectively. In cases with single brain metastasis, the organ-at-risk doses with jaw tracking were also lower than no jaw tracking. The Dmax and Dmean of organ-at-risk doses reduced 0.84% to 1.52% and 0.90% to 1.86%, P < .05, respectively. The monitor units for the large tumor and small tumor were increased by 2.41% and 1.1%, respectively. The γ passing rates (3mm/3%, th10%; 2mm/2%, th10%) of nasopharyngeal carcinoma plans are 99.89% ± 0.06% (jaw tracking) versus 99.56% ± 0.19% (no jaw tracking; P = .127); 97.15% ± 0.98% (jaw tracking) versus 91.90% ± 1.40% (no jaw tracking; P = .000), and the γ passing rates (3mm/3%, th10%; 2mm/2%, th10%) of brain metastasis plans are 99.97% ± 0.05% (jaw tracking) versus 99.44% ± 1.24% (no jaw tracking; P = .251), 98.65% ± 1.27% (jaw tracking) versus 93.35% ± 2.72% (no jaw tracking; P = .000). Conclusion: Jaw tracking can reduce the dose of organ-at-risks compared to no jaw tracking, and the effect is more significant for plans with large tumor. The γ passing rate of plans with jaw tracking is also higher than the plans with no jaw tracking. Although the monitor units in plans of jaw tracking will increase slightly, it is recommended to use jaw tracking in static intensity-modulated radiation therapy both in large and in small tumors.

1 July 2018 in American Journal of Clinical Oncology
Verified
Journal Article
Open access
PDF file
YLYong Liu
Yong Liu
GZGuoqi Zhao
Guoqi Zhao
YXYi Xu
Yi Xu
TZTiening Zhang
Tiening Zhang
ZCZhixiao Chen
Zhixiao Chen
TCTingfeng Chen
Tingfeng Chen
The Intergroup 0116 study has demonstrated a significant survival benefit for completely resected (R0) gastric cancer patients treated with a fluorouracil/leucovorin chemoradiotherapy regimen. However, this regimen is also toxic and less effective in terms of distant disease control. Therefore, a more efficacious and safer regimen is urgently needed. Patients with R0 resected gastric carcinoma received up to two 21-day cycles of postoperative adjuvant preradiation and postradiation DCF chemotherapy (docetaxel 37.5 mg/m2 on days 1 and 8, cisplatin 25 mg/m2 on days 1 to 3, and a continuous infusion of fluorouracil 750 mg/m2 on days 1 to 5), respectively. Chemoradiotherapy between preradiation and postradiation chemotherapy was initiated on day 43 and consisted of intensity-modulated radiotherapy (45 Gy) plus concurrent docetaxel 20 mg/m2 weekly for 5 weeks. A total of 55 patients were evaluated and 76% (42) of patients completed the prescribed therapy. With a median follow-up of 61 months, the 3- and 5-year progression-free survival rates were 67% (95% confidence interval [CI], 54%-80%) and 59% (95% CI, 46%-72%), respectively; and the 3- and 5-year overall survival rates were 72% (95% CI, 60%-84%) and 61% (95% CI, 48%-74%), respectively. The most common grade 3 or greater toxicity, during the chemotherapy phase, was neutropenia (24%). Common grade 3/4 toxicities during concurrent chemoradiotherapy were nausea (32%), vomiting (26%), fatigue (15%), and anorexia (19%). These results demonstrate that this adjuvant regimen is active with an acceptable toxicity profile. A randomized phase 3 trial comparing the Intergroup 0116 chemoradiotherapy regimen with this regimen is underway. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0/

28 November 2025 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
QLQianqian Liu
Qianqian Liu
XCXuming Chen
Xuming Chen
ZHZhekai Hu
Zhekai Hu
LHLingtong Hou
Lingtong Hou
YZYihang Zhang
Yihang Zhang
SYShengyu Yao
Shengyu Yao
Purpose: To evaluate the fitting accuracy and dose influence of 3D‐printed bolus (3DPB) during postmastectomy radiotherapy. Methods: Air gaps were assessed using cone‐beam computed tomography (CBCT) images for 27 breast cancer patients who received postmastectomy radiotherapy. Then a CIRS thoracic phantom was used to evaluate the dosimetric effects of different air gap sizes. Results: In CBCT images of patients, compared with conventional bolus (CB), 3DPB significantly reduced both the maximum and total air gap volumes by an average between 103.04 cm 3 and 124.63 cm 3 , respectively. The average maximum gap height was 0.53 ± 0.20 cm for 3DPB and 2.23 ± 0.41 cm for CB (p 2 cm, the dose reduction becomes significant, warranting the use of 3D‐printed boluses to ensure adequate target coverage.

1 January 2021 in Technology in Cancer Research & Treatment
Verified
Journal Article
Open access
PDF file
LHLingtong Hou
Lingtong Hou
HZHuiqin Zhang
Huiqin Zhang
XSXiaomei Sun
Xiaomei Sun
QLQianqian Liu
Qianqian Liu
TCTingfeng Chen
Tingfeng Chen
SYShengyu Yao
Shengyu Yao
Purpose: To evaluate the dosimetric accuracy of the default couch model of the QFix kVueTM Calypso couch top in the treatment planning system. Methods: With the gantry 180°, field size 20 × 20 cm, 6 MV, we measured the depth dose, off-axis dose, and dose plane of different depths in the phantom with the couch rails in and out, respectively. Isocenter doses at different angles were also obtained. The results were compared to the doses calculated using the default couch top model and the real scanned couch top model. Then we revised the default model according to the measured results. Results: With “Rails In,” the depth dose, off-axis dose, and dose plane of the default couch top model had a big difference with the dose of the real scanned couch top model and the measured result. The dose of the real scanned couch top model was much closer to the measured result, but in the region of the rail edge, the difference was still significant. With “Rails Out,” there was a minor difference between the measured result, the dose of the default couch top model and the real scanned couch top model. The difference between the measurement and the default couch top model became very small after being revised. Conclusions: It is better to avoid the beam angle passing through the couch rails in treatment plans, or you should revise the parameter of the QFix kVueTM Calypso couch top model based on the measured results, and verify the treatment plan before clinical practice.