Josefina Gutiérrez-Martínez

Dr. Josefina Gutiérrez-Martínez

Instituto Nacional de Rehabilitación, Mexico City, Ciudad de México, Mexico

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2022 in Electronics
Verified
Journal Article
Open access
PDF file
CTCinthya Lourdes Toledo-Peral
Cinthya Lourdes Toledo-Peral
GVGabriel Vega-Martínez
Gabriel Vega-Martínez
JGJorge Airy Mercado Gutierrez
Jorge Airy Mercado Gutierrez
GRGerardo Rodriguez-Reyes
Gerardo Rodriguez-Reyes
AVArturo Vera-Hernández
Arturo Vera-Hernández
JGJosefina Gutiérrez-Martínez
Josefina Gutiérrez-Martínez
Virtual reality (VR) and augmented reality (AR) are engaging interfaces that can be of benefit for rehabilitation therapy. However, they are still not widely used, and the use of surface electromyography (sEMG) signals is not established for them. Our goal is to explore whether there is a standardized protocol towards therapeutic applications since there are not many methodological reviews that focus on sEMG control/feedback. A systematic literature review using the PRISMA (preferred reporting items for systematic reviews and meta-analyses) methodology is conducted. A Boolean search in databases was performed applying inclusion/exclusion criteria; articles older than 5 years and repeated were excluded. A total of 393 articles were selected for screening, of which 66.15% were excluded, 131 records were eligible, 69.46% use neither VR/AR interfaces nor sEMG control; 40 articles remained. Categories are, application: neurological motor rehabilitation (70%), prosthesis training (30%); processing algorithm: artificial intelligence (40%), direct control (20%); hardware: Myo Armband (22.5%), Delsys (10%), proprietary (17.5%); VR/AR interface: training scene model (25%), videogame (47.5%), first-person (20%). Finally, applications are focused on motor neurorehabilitation after stroke/amputation; however, there is no consensus regarding signal processing or classification criteria. Future work should deal with proposing guidelines to standardize these technologies for their adoption in clinical practice.

25 November 2021 in Frontiers in Human Neuroscience
Verified
Journal Article
Open access
JGJosefina Gutiérrez-Martínez
Josefina Gutiérrez-Martínez
JMJorge A. Mercado-Gutierrez
Jorge A. Mercado-Gutierrez
BCBlanca E. Carvajal-Gámez
Blanca E. Carvajal-Gámez
JRJorge L. Rosas-Trigueros
Jorge L. Rosas-Trigueros
ACAdrian E. Contreras-Martinez
Adrian E. Contreras-Martinez
Brain-Computer Interface (BCI) is a technology that uses electroencephalographic (EEG) signals to control external devices, such as Functional Electrical Stimulation (FES). Visual BCI paradigms based on P300 and Steady State Visually Evoked potentials (SSVEP) have shown high potential for clinical purposes. Numerous studies have been published on P300- and SSVEP-based non-invasive BCIs, but many of them present two shortcomings: (1) they are not aimed for motor rehabilitation applications, and (2) they do not report in detail the artificial intelligence (AI) methods used for classification, or their performance metrics. To address this gap, in this paper the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) methodology was applied to prepare a systematic literature review (SLR). Papers older than 10 years, repeated or not related to a motor rehabilitation application, were excluded. Of all the studies, 51.02% referred to theoretical analysis of classification algorithms. Of the remaining, 28.48% were for spelling, 12.73% for diverse applications (control of wheelchair or home appliances), and only 7.77% were focused on motor rehabilitation. After the inclusion and exclusion criteria were applied and quality screening was performed, 34 articles were selected. Of them, 26.47% used the P300 and 55.8% the SSVEP signal. Five applications categories were established: Rehabilitation Systems (17.64%), Virtual Reality environments (23.52%), FES (17.64%), Orthosis (29.41%), and Prosthesis (11.76%). Of all the works, only four performed tests with patients. The most reported machine learning (ML) algorithms used for classification were linear discriminant analysis (LDA) (48.64%) and support vector machine (16.21%), while only one study used a deep learning algorithm: a Convolutional Neural Network (CNN). The reported accuracy ranged from 38.02 to 100%, and the Information Transfer Rate from 1.55 to 49.25 bits per minute. While LDA is still the most used AI algorithm, CNN has shown promising results, but due to their high technical implementation requirements, many researchers do not justify its implementation as worthwile. To achieve quick and accurate online BCIs for motor rehabilitation applications, future works on SSVEP-, P300-based and hybrid BCIs should focus on optimizing the visual stimulation module and the training stage of ML and DL algorithms.

12 June 2025 in Current Medical Imaging
Verified
Journal Article
Open access
PDF file
ASALBERTO ISAAC PEREZ SANPABLO
ALBERTO ISAAC PEREZ SANPABLO
JQJimena Quinzaños-Fresnedo
Jimena Quinzaños-Fresnedo
JGJosefina Gutiérrez-Martínez
Josefina Gutiérrez-Martínez
IRIrma G. Lozano- Rodríguez
Irma G. Lozano- Rodríguez
Ernesto Roldan-ValadezErnesto Roldan-Valadez
Ernesto Roldan-Valadez
Introduction: To examine the integration of artificial intelligence (AI) into Picture Archiving and Communication Systems (PACS) and assess its impact on medical imaging, diagnostic workflows, and patient outcomes. This review explores the technological evolution, key advancements, and challenges associated with AI-enhanced PACS in healthcare settings. Methods: A comprehensive literature search was conducted in PubMed, Scopus, and Web of Science databases, covering articles from January 2000 to October 2024. Search terms included “artificial intelligence,” “machine learning,” “deep learning,” and “PACS,” combined with keywords related to diagnostic accuracy and workflow optimization. Articles were selected based on predefined inclusion and exclusion criteria, focusing on peerreviewed studies that discussed AI applications in PACS, innovations in medical imaging, and workflow improvements. A total of 183 studies met the inclusion criteria, comprising original research, systematic reviews, and meta-analyses. Results: AI integration in PACS has significantly enhanced diagnostic accuracy, achieving improvements of up to 93.2% in some imaging modalities, such as early tumor detection and anomaly identification. Workflow efficiency has been transformed, with diagnostic times reduced by up to 90% for critical conditions like intracranial hemorrhages. Convolutional neural networks (CNNs) have demonstrated exceptional performance in image segmentation, achieving up to 94% accuracy, and in motion artifact correction, further enhancing diagnostic precision. Natural language processing (NLP) tools have expedited radiology workflows, reducing reporting times by 30–50% and improving consistency in report generation. Cloudbased solutions have also improved accessibility, enabling real-time collaboration and remote diagnostics. However, challenges in data privacy, regulatory compliance, and interoperability persist, emphasizing the need for standardized frameworks and robust security protocols. Conclusions: The integration of AI into PACS represents a pivotal transformation in medical imaging, offering improved diagnostic workflows and potential for personalized patient care. Addressing existing challenges and enhancing interoperability will be essential for maximizing the benefits of AIpowered PACS in healthcare.

1 January 2014 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
JCJessica Cantillo-Negrete
Jessica Cantillo-Negrete
JGJosefina Gutiérrez-Martínez
Josefina Gutiérrez-Martínez
RCRuben I. Carino-Escobar
Ruben I. Carino-Escobar
PCPaul Carrillo-Mora
Paul Carrillo-Mora
DEDavid Elias-Vinas
David Elias-Vinas
One of the difficulties for the implementation of Brain-Computer Interface (BCI) systems for motor impaired patients is the time consumed in the system design process, since patients do not have the adequate physical nor psychological conditions to complete the process. For this reason most of BCIs are designed in a subject-dependent approach using data of healthy subjects. The developing of subject-independent systems is an option to decrease the required training sessions to design a BCI with patient functionality. This paper presents a proof-of-concept study to evaluate subject-independent system based on hand motor imagery taking gender into account. Subject-Independent BCIs are proposed using Common Spatial Patterns and log variance features of two groups of healthy subjects; one of the groups was composed by people of male gender and the other one by people of female gender. The performance of the developed gender-specific BCI designs was evaluated with respect to a subject-independent BCI designed without taking gender into account, and afterwards its performance was evaluated with data of two healthy subjects that were not included in the initial sample. As an additional test to probe the potential use for subcortical stroke patients we applied the methodology to two patients with right hand weakness. T-test was employed to determine the significance of the difference between traditional approach and the proposed gender-specific approach. For most of the tested conditions, the gender-specific BCIs have a statistically significant better performance than those that did not take gender into account. It was also observed that with a BCI designed with log-variance features in the alpha and beta band of healthy subjects’ data, it was possible to classify hand motor imagery of subcortical stroke patients above the practical level of chance. A larger subjects’ sample test may be necessary to improve the performances of the gender-specific BCIs and to further test this methodology on different patients. The reduction of complexity in the implementation of BCI systems could bring these systems closer to applications such as controlling devices for the motor rehabilitation of stroke patients, and therefore, contribute to a more effective neurological rehabilitation.

1 January 2016 in Annals of Rehabilitation Medicine
Verified
Journal Article
Open access
PDF file
SMSalvador Israel Macías-Hernández
Salvador Israel Macías-Hernández
DVDiana Sureima Vásquez-Sotelo
Diana Sureima Vásquez-Sotelo
MFMarco Vinicio Ferruzca-Navarro
Marco Vinicio Ferruzca-Navarro
SSSusana Hazel Badillo Sánchez
Susana Hazel Badillo Sánchez
JGJosefina Gutiérrez-Martínez
Josefina Gutiérrez-Martínez
JMJuan Daniel Morones-Alba
Juan Daniel Morones-Alba
Macías-Hernández SI, et al. Ann Rehabil Med. 2016 Aug;40(4):710-717. https://doi.org/10.5535/arm.2016.40.4.710

9 September 2022 in Brain Sciences
Verified
Journal Article
Open access
PDF file
MGMario Ibrahin Gutierrez
Mario Ibrahin Gutierrez
IPIrais Poblete-Naredo
Irais Poblete-Naredo
JGJorge Airy Mercado Gutierrez
Jorge Airy Mercado Gutierrez
CTCinthya Lourdes Toledo-Peral
Cinthya Lourdes Toledo-Peral
JQJimena Quinzaños-Fresnedo
Jimena Quinzaños-Fresnedo
JGJosefina Gutiérrez-Martínez
Josefina Gutiérrez-Martínez
The technology for transcranial magnetic stimulation (TMS) has significantly changed over the years, with important improvements in the signal generators, the coils, the positioning systems, and the software for modeling, optimization, and therapy planning. In this systematic literature review (SLR), the evolution of each component of TMS technology is presented and analyzed to assess the limitations to overcome. This SLR was carried out following the PRISMA 2020 statement. Published articles of TMS were searched for in four databases (Web of Science, PubMed, Scopus, IEEE). Conference papers and other reviews were excluded. Records were filtered using terms about TMS technology with a semi-automatic software; articles that did not present new technology developments were excluded manually. After this screening, 101 records were included, with 19 articles proposing new stimulator designs (18.8%), 46 presenting or adapting coils (45.5%), 18 proposing systems for coil placement (17.8%), and 43 implementing algorithms for coil optimization (42.6%). The articles were blindly classified by the authors to reduce the risk of bias. However, our results could have been influenced by our research interests, which would affect conclusions for applications in psychiatric and neurological diseases. Our analysis indicates that more emphasis should be placed on optimizing the current technology with a special focus on the experimental validation of models. With this review, we expect to establish the base for future TMS technological developments.