Cinthya Lourdes Toledo-Peral

Dr. Cinthya Lourdes Toledo-Peral

Instituto Nacional de Rehabilitación, Mexico City, Ciudad de México, Mexico
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2022 in Electronics
Verified
Journal Article
Open access
PDF file
CTCinthya Lourdes Toledo-Peral
Cinthya Lourdes Toledo-Peral
GVGabriel Vega-Martínez
Gabriel Vega-Martínez
JGJorge Airy Mercado Gutierrez
Jorge Airy Mercado Gutierrez
GRGerardo Rodriguez-Reyes
Gerardo Rodriguez-Reyes
AVArturo Vera-Hernández
Arturo Vera-Hernández
JGJosefina Gutiérrez-Martínez
Josefina Gutiérrez-Martínez
Virtual reality (VR) and augmented reality (AR) are engaging interfaces that can be of benefit for rehabilitation therapy. However, they are still not widely used, and the use of surface electromyography (sEMG) signals is not established for them. Our goal is to explore whether there is a standardized protocol towards therapeutic applications since there are not many methodological reviews that focus on sEMG control/feedback. A systematic literature review using the PRISMA (preferred reporting items for systematic reviews and meta-analyses) methodology is conducted. A Boolean search in databases was performed applying inclusion/exclusion criteria; articles older than 5 years and repeated were excluded. A total of 393 articles were selected for screening, of which 66.15% were excluded, 131 records were eligible, 69.46% use neither VR/AR interfaces nor sEMG control; 40 articles remained. Categories are, application: neurological motor rehabilitation (70%), prosthesis training (30%); processing algorithm: artificial intelligence (40%), direct control (20%); hardware: Myo Armband (22.5%), Delsys (10%), proprietary (17.5%); VR/AR interface: training scene model (25%), videogame (47.5%), first-person (20%). Finally, applications are focused on motor neurorehabilitation after stroke/amputation; however, there is no consensus regarding signal processing or classification criteria. Future work should deal with proposing guidelines to standardize these technologies for their adoption in clinical practice.

1 March 2009
Verified
Conference Paper
Closed access
CTCinthya Lourdes Toledo-Peral
Cinthya Lourdes Toledo-Peral
LLL. Leija
L. Leija
RMRoberto Muñoz
Roberto Muñoz
AVArturo Vera-Hernández
Arturo Vera-Hernández
ARA. Ramirez
A. Ramirez
In this article, it will be described the state of the art of upper limb prosthesis and several types of them. The prosthesis evolution had allowed people who lost an extremity to win back their normal life and live it with fewer limitations. Designing a myoelectric prosthetic arm that interacts with the amputee requires the integration of countless disciplines. Traditional commercial prosthesis has at least three degrees of freedom: open and close the hook, bend and straighten the elbow and rotate the wrist; but the human arm has 22 degrees of freedom. Thus, it is important to realize that the prosthetics have a long way to go. Furthermore, the higher the amputation level, the greater the demands on the fitting technique. Each prosthesis has different characteristics, advantages and drawbacks. Finally, four different kind of prosthesis will be presented: the Boston Elbow, the Utah Arm, the Kuiken's Prosthesis within DARPA's Project and the prosthesis under development in our laboratory.

9 September 2022 in Brain Sciences
Verified
Journal Article
Open access
PDF file
MGMario Ibrahin Gutierrez
Mario Ibrahin Gutierrez
IPIrais Poblete-Naredo
Irais Poblete-Naredo
JGJorge Airy Mercado Gutierrez
Jorge Airy Mercado Gutierrez
CTCinthya Lourdes Toledo-Peral
Cinthya Lourdes Toledo-Peral
JQJimena Quinzaños-Fresnedo
Jimena Quinzaños-Fresnedo
JGJosefina Gutiérrez-Martínez
Josefina Gutiérrez-Martínez
The technology for transcranial magnetic stimulation (TMS) has significantly changed over the years, with important improvements in the signal generators, the coils, the positioning systems, and the software for modeling, optimization, and therapy planning. In this systematic literature review (SLR), the evolution of each component of TMS technology is presented and analyzed to assess the limitations to overcome. This SLR was carried out following the PRISMA 2020 statement. Published articles of TMS were searched for in four databases (Web of Science, PubMed, Scopus, IEEE). Conference papers and other reviews were excluded. Records were filtered using terms about TMS technology with a semi-automatic software; articles that did not present new technology developments were excluded manually. After this screening, 101 records were included, with 19 articles proposing new stimulator designs (18.8%), 46 presenting or adapting coils (45.5%), 18 proposing systems for coil placement (17.8%), and 43 implementing algorithms for coil optimization (42.6%). The articles were blindly classified by the authors to reduce the risk of bias. However, our results could have been influenced by our research interests, which would affect conclusions for applications in psychiatric and neurological diseases. Our analysis indicates that more emphasis should be placed on optimizing the current technology with a special focus on the experimental validation of models. With this review, we expect to establish the base for future TMS technological developments.

14 March 2018 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
CTCinthya Lourdes Toledo-Peral
Cinthya Lourdes Toledo-Peral
JGJosefina Gutiérrez-Martínez
Josefina Gutiérrez-Martínez
JGJorge Airy Mercado Gutierrez
Jorge Airy Mercado Gutierrez
AMAna Isabel Martín-Vignon-Whaley
Ana Isabel Martín-Vignon-Whaley
AVArturo Vera-Hernández
Arturo Vera-Hernández
LLLorenzo Leija-Salas
Lorenzo Leija-Salas
Due to damage of the nervous system, patients experience impediments in their daily life: severe fatigue, tremor or impaired hand dexterity, hemiparesis, or hemiplegia. Surface electromyography (sEMG) signal analysis is used to identify motion; however, standardization of electrode placement and classification of sEMG patterns are major challenges. This paper describes a technique used to acquire sEMG signals for five hand motion patterns from six able-bodied subjects using an array of recording and stimulation electrodes placed on the forearm and its effects over functional electrical stimulation (FES) and volitional sEMG combinations, in order to eventually control a sEMG-driven FES neuroprosthesis for upper limb rehabilitation. A two-part protocol was performed. First, personalized templates to place eight sEMG bipolar channels were designed; with these data, a universal template, called forearm electrode set (FELT), was built. Second, volitional and evoked movements were recorded during FES application. 95% classification accuracy was achieved using two sessions per movement. With the FELT, it was possible to perform FES and sEMG recordings simultaneously. Also, it was possible to extract the volitional and evoked sEMG from the raw signal, which is highly important for closed-loop FES control.

7 October 2020 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
JGJosefina Gutiérrez-Martínez
Josefina Gutiérrez-Martínez
CTCinthya Lourdes Toledo-Peral
Cinthya Lourdes Toledo-Peral
JMJorge Mercado-Gutiérrez
Jorge Mercado-Gutiérrez
AVArturo Vera-Hernández
Arturo Vera-Hernández
LLLorenzo Leija
Lorenzo Leija
Background. A neuroprosthesis (NP) is a medical device that compensates and restores functionality of neural dysfunctions affected by different pathologies and conditions. To this end, an implantable NP (INP) must monitor and electrically stimulate neuronal small structures in the peripheral and central nervous system. Therefore, one of the most important parts of INPs are the sensors and electrodes since their size, resolution, and material are key for their design and performance. Currently, most of the studies focus only on the INP application but do not show the technical considerations of the sensors. Objective. This paper is a systematic literature review that summarizes and synthesizes implantable micro- and nanosensors/electrodes used in INPs for sensing and stimulating tissues. Data Sources. Articles and patents published in English were searched from electronic databases. No restrictions were made in terms of country or journal. Study Selection. All reports related to sensors/electrodes applied in INPs were included, focusing on micro- and nanotechnologies. Main Outcome Measures. Performance and potential profit. Results. There was a total of 153 selected articles from the 2010 to June 2020 period, of which 16 were about cardiac pacemakers, 15 cochlear implants, 13 retinal prosthesis, 31 deep brain stimulation, 6 bladder implants, and 18 implantable motor NPs. All those INPs are used for support or recovery of neural functions for hearing, seeing, pacing, and motor control, as well as bladder and bowel control. Micro- and nanosensors for signal stimulation and recording have four special requirements to meet: biocompatibility, long-term reliability, high selectivity, and low-energy consumption. Current and future considerations in sensor/electrode design should focus on improving efficiency and safety. This review is a first approximation for those who work on INP design; it offers an idea of the complexity on the matter and can guide them to specific references on the subject.

16 December 2018 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
CTCinthya Lourdes Toledo-Peral
Cinthya Lourdes Toledo-Peral
FBFrancisco José Ramos Becerril
Francisco José Ramos Becerril
GMGabriel Vega Martínez
Gabriel Vega Martínez
AVArturo Vera-Hernández
Arturo Vera-Hernández
LSLorenzo Leija Salas
Lorenzo Leija Salas
JGJosefina Gutiérrez-Martínez
Josefina Gutiérrez-Martínez
Diabetic skin manifestations, previous to ulcers and wounds, are not highly accounted as part of diagnosis even when they represent the first symptom of vascular damage and are present in up to 70% of patients with diabetes mellitus type II. Here, an application for skin macules characterization based on a three-stage segmentation and characterization algorithm used to classify vascular, petechiae, trophic changes, and trauma macules from digital photographs of the lower limbs is presented. First, in order to find the skin region, a logical multiplication is performed on two skin masks obtained from color space transformations; dynamic thresholds are stabilised to self-adjust to a variety of skin tones. Then, in order to locate the lesion region, illumination enhancement is performed using a chromatic model color space, followed by a principal component analysis gray-scale transformation. Finally, characteristics of each type of macule are considered and classified; morphologic properties (area, axes, perimeter, and solidity), intensity properties, and a set of shade indices (red, green, blue, and brown) are proposed as a measure to obviate skin color differences among subjects. The values calculated show differences between macules with a statistical significance, which agree with the physician’s diagnosis. Later, macule properties are fed to an artificial neural network classifier, which proved a 97.5% accuracy, to differentiate between them. Characterization is useful in order to track macule changes and development along time, provides meaningful information to provide early treatments, and offers support in the prevention of amputations due to diabetic feet. A graphical user interface was designed to show the properties of the macules; this application could be the background of a future Diagnosis Assistance Tool for educational (i.e., untrained physicians) and preventive assistance technology purposes.