Wayne Wonseok-Choi Rodgers

Mr. Wayne Wonseok-Choi Rodgers

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2025 in Journal of Biomedical Optics
Verified
Journal Article
Open access
RZRuizhi Zuo
Ruizhi Zuo
SWShuwen Wei
Shuwen Wei
WYWang Yaning
Wang Yaning
RHRuichen Huang
Ruichen Huang
WRWayne Wonseok-Choi Rodgers
Wayne Wonseok-Choi Rodgers
JJin U. Kang
Jin U. Kang
SignificanceConventional fringe projection profilometry (FPP) requires multiple image acquisitions and therefore long acquisition times that make it slow for high-speed dynamic measurements. We propose and demonstrate a deep-learning-based single-shot FPP system utilizing a single endoscope for surgical guidance.AimWe aim to achieve real-time depth map generation of target tissues with high accuracy for robotic surgical guidance.ApproachWe proposed an endoscopic single-shot FPP system based on a deep learning network to generate real-time accurate tissue depth maps for surgical guidance. The system utilizes a dual-channel endoscope, where one channel projects fringe patterns from a projector and the other channel collects images using a camera. In addition, we developed a data synthesis method to generate a large number of diverse training datasets. The network consists of MaskNet, which segments the tissue from the background, and DepthNet, which predicts the depth map of the image. The results from both networks are combined to generate the final depth map.ResultsWe tested our algorithm using fringe patterns with different frequencies and found that the optimal frequency for single-shot FPP in our setup is 20 Hz. The algorithm has been tested on both synthetic and experimental data, achieving a maximum depth prediction error of ∼2 mm and a processing time of about 12.75 ms per frame.ConclusionA deep-learning-based single-shot FPP endoscopic system was shown to be highly effective in real-time depth map generation with millimeter-scale error. Implementing such a system has the potential to improve the reliability of image-guided robotic surgery.

24 April 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
WRWayne Wonseok-Choi Rodgers
Wayne Wonseok-Choi Rodgers
HSHyunwoo Song
Hyunwoo Song
JYJinglun Yu
Jinglun Yu
APAlexandra Patterson
Alexandra Patterson
JSJames Spicer
James Spicer
JKJin U. Kang
Jin U. Kang
We present experimental and numerical studies of annular photoacoustic beam generation using a vortex half-wave retarder that enables controlled acoustic pressure localization. The retarder shapes a Gaussian beam into a ring-shaped annular beam, which produces annular photoacoustic signals when absorbed by polydimethylsiloxane (PDMS)-based thin films. The resulting acoustic fields were modeled using the k-Wave toolbox incorporating experimentally measured optical fluence profiles and material parameters. Simulations were quantitatively compared with hydrophone measurements, showing strong agreement in peak pressure amplitude, axial localization, and spatial pressure distribution. The effects of topological charge and condensing lens configuration on delivered fluence and acoustic field geometry were systematically evaluated. These results support that annular-beam photoacoustic generation is an effective strategy for tailoring field localization, with potential applications in localized energy delivery, minimally invasive sensing, and biomedical imaging and stimulation.