Wang Yaning

Dr. Wang Yaning


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2024 in Biomedical Optics Express
Verified
Journal Article
Closed access
WYWang Yaning
Wang Yaning
SWShuwen Wei
Shuwen Wei
RZRuizhi Zuo
Ruizhi Zuo
MKMichael Kam
Michael Kam
JOJustin D. Opfermann
Justin D. Opfermann
JKJin U. Kang
Jin U. Kang
Anastomosis is a common and critical part of reconstructive procedures within gastrointestinal, urologic, and gynecologic surgery. The use of autonomous surgical robots such as the smart tissue autonomous robot (STAR) system demonstrates an improved efficiency and consistency of the laparoscopic small bowel anastomosis over the current da Vinci surgical system. However, the STAR workflow requires auxiliary manual monitoring during the suturing procedure to avoid missed or wrong stitches. To eliminate this monitoring task from the operators, we integrated an optical coherence tomography (OCT) fiber sensor with the suture tool and developed an automatic tissue classification algorithm for detecting missed or wrong stitches in real time. The classification results were updated and sent to the control loop of STAR robot in real time. The suture tool was guided to approach the object by a dual-camera system. If the tissue inside the tool jaw was inconsistent with the desired suture pattern, a warning message would be generated. The proposed hybrid multilayer perceptron dual-channel convolutional neural network (MLP-DC-CNN) classification platform can automatically classify eight different abdominal tissue types that require different suture strategies for anastomosis. In MLP, numerous handcrafted features (∼1955) were utilized including optical properties and morphological features of one-dimensional (1D) OCT A-line signals. In DC-CNN, intensity-based features and depth-resolved tissues’ attenuation coefficients were fully exploited. A decision fusion technique was applied to leverage the information collected from both classifiers to further increase the accuracy. The algorithm was evaluated on 69,773 testing A-line data. The results showed that our model can classify the 1D OCT signals of small bowels in real time with an accuracy of 90.06%, a precision of 88.34%, and a sensitivity of 87.29%, respectively. The refresh rate of the displayed A-line signals was set as 300 Hz, the maximum sensing depth of the fiber was 3.6 mm, and the running time of the image processing algorithm was ∼1.56 s for 1,024 A-lines. The proposed fully automated tissue sensing model outperformed the single classifier of CNN, MLP, or SVM with optimized architectures, showing the complementarity of different feature sets and network architectures in classifying intestinal OCT A-line signals. It can potentially reduce the manual involvement of robotic laparoscopic surgery, which is a crucial step towards a fully autonomous STAR system.

1 November 2022 in Journal of Medical Imaging
Verified
Journal Article
Open access
PDF file
WYWang Yaning
Wang Yaning
LTLaura Tiusaba
Laura Tiusaba
SJShimon Jacobs
Shimon Jacobs
MSMichele Saruwatari
Michele Saruwatari
BNBo Ning
Bo Ning
RCRichard Jaepyeong Cha
Richard Jaepyeong Cha
PurposeIntraoperative evaluation of bowel perfusion is currently dependent upon subjective assessment. Thus, quantitative and objective methods of bowel viability in intestinal anastomosis are scarce. To address this clinical need, a conditional adversarial network is used to analyze the data from laser speckle contrast imaging (LSCI) paired with a visible-light camera to identify abnormal tissue perfusion regions.ApproachOur vision platform was based on a dual-modality bench-top imaging system with red-green-blue (RGB) and dye-free LSCI channels. Swine model studies were conducted to collect data on bowel mesenteric vascular structures with normal/abnormal microvascular perfusion to construct the control or experimental group. Subsequently, a deep-learning model based on a conditional generative adversarial network (cGAN) was utilized to perform dual-modality image alignment and learn the distribution of normal datasets for training. Thereafter, abnormal datasets were fed into the predictive model for testing. Ischemic bowel regions could be detected by monitoring the erroneous reconstruction from the latent space. The main advantage is that it is unsupervised and does not require subjective manual annotations. Compared with the conventional qualitative LSCI technique, it provides well-defined segmentation results for different levels of ischemia.ResultsWe demonstrated that our model could accurately segment the ischemic intestine images, with a Dice coefficient and accuracy of 90.77% and 93.06%, respectively, in 2560 RGB/LSCI image pairs. The ground truth was labeled by multiple and independent estimations, combining the surgeons’ annotations with fastest gradient descent in suspicious areas of vascular images. The total processing time was 0.05 s for an image size of 256 × 256.ConclusionsThe proposed cGAN can provide pixel-wise and dye-free quantitative analysis of intestinal perfusion, which is an ideal supplement to the traditional LSCI technique. It has potential to help surgeons increase the accuracy of intraoperative diagnosis and improve clinical outcomes of mesenteric ischemia and other gastrointestinal surgeries.

1 August 2025 in Journal of Biomedical Optics
Verified
Journal Article
Open access
RZRuizhi Zuo
Ruizhi Zuo
SWShuwen Wei
Shuwen Wei
WYWang Yaning
Wang Yaning
RHRuichen Huang
Ruichen Huang
WRWayne Wonseok-Choi Rodgers
Wayne Wonseok-Choi Rodgers
JJin U. Kang
Jin U. Kang
SignificanceConventional fringe projection profilometry (FPP) requires multiple image acquisitions and therefore long acquisition times that make it slow for high-speed dynamic measurements. We propose and demonstrate a deep-learning-based single-shot FPP system utilizing a single endoscope for surgical guidance.AimWe aim to achieve real-time depth map generation of target tissues with high accuracy for robotic surgical guidance.ApproachWe proposed an endoscopic single-shot FPP system based on a deep learning network to generate real-time accurate tissue depth maps for surgical guidance. The system utilizes a dual-channel endoscope, where one channel projects fringe patterns from a projector and the other channel collects images using a camera. In addition, we developed a data synthesis method to generate a large number of diverse training datasets. The network consists of MaskNet, which segments the tissue from the background, and DepthNet, which predicts the depth map of the image. The results from both networks are combined to generate the final depth map.ResultsWe tested our algorithm using fringe patterns with different frequencies and found that the optimal frequency for single-shot FPP in our setup is 20 Hz. The algorithm has been tested on both synthetic and experimental data, achieving a maximum depth prediction error of ∼2 mm and a processing time of about 12.75 ms per frame.ConclusionA deep-learning-based single-shot FPP endoscopic system was shown to be highly effective in real-time depth map generation with millimeter-scale error. Implementing such a system has the potential to improve the reliability of image-guided robotic surgery.

1 August 2023 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
WYWang Yaning
Wang Yaning
SWShuwen Wei
Shuwen Wei
JJin U. Kang
Jin U. Kang
Optical coherence tomography (OCT)1 can acquire high resolution cross-sectional images of biological samples by measuring their backscattered signals and has become a widely used tool for microstructure analysis,2 disease diagnosis, and biomedical imaging.3,4 However, OCT image contrast comes from the small range of in-sample refractive index variations, around 1.3 to 1.5,5 and this makes accurate real-time assessment of biological tissue challenging. To obtain accurate tissue anatomical structure information, there has been a growing interest in OCT attenuation coefficient imaging,5,6 which measures the light decay associated with the absorption and scattering. Following Lambert–Beer’s law, the irradiance L exhibits an exponential decay along the penetrating depth z, which can be written as

15 June 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
JOJustin Opfermann
Justin Opfermann
WYWang Yaning
Wang Yaning
JKJames Kaluna
James Kaluna
KSKensei Suzuki
Kensei Suzuki
WGWilliam Gensheimer
William Gensheimer
JJin U. Kang
Jin U. Kang
Partial-thickness corneal transplants using a deep anterior lamellar keratoplasty (DALK) approach has demonstrated better patient outcomes than a full-thickness cornea transplant. However, despite better clinical outcomes from the DALK procedure, adoption of the technique has been limited because the accurate insertion of the needle into the deep stroma remains technically challenging. In this work, we present a novel hands-free eye mountable robot for automatic needle placement in the cornea, AutoDALK, that has the potential to simplify this critical step in the DALK procedure. The system integrates dual light-weight linear piezo motors, an OCT A-scan distance sensor, and a vacuum trephine-inspired design to enable the safe, consistent, and controllable insertion of a needle into the cornea for the pneumodissection of the anterior cornea from the deep posterior cornea and Descemet’s membrane. AutoDALK was designed with feedback from expert corneal surgeons and performance was evaluated by finite element analysis simulation, benchtop testing, and ex vivo experiments to demonstrate the feasibility of the system for clinical applications. The mean open-loop positional deviation was 9.39 µm, while the system repeatability and accuracy were 39.48 µm and 43.18 µm, respectively. The maximum combined thrust of the system was found to be 1.72 N, which exceeds the clinical penetration force of the cornea. In a head-to-head ex vivo comparison against an expert surgeon using a freehand approach, AutoDALK achieved more consistent needle depth, which resulted in fewer perforations of Descemet’s membrane and significantly deeper pneumodissection of the stromal tissue. The results of this study indicate that robotic needle insertion has the potential to simplify the most challenging task of the DALK procedure, enable more consistent surgical outcomes for patients, and standardize partial-thickness corneal transplants as the gold standard of care if demonstrated to be more safe and more effective than penetrating keratoplasty.

2 March 2022 in Proceedings of SPIE
Verified
Conference Paper
Closed access
PDF file
WYWang Yaning
Wang Yaning
SWShuwen Wei
Shuwen Wei
JKJin U. Kang
Jin U. Kang
Optical coherence tomography (OCT) with a robust depth-resolved attenuation compensation method for a wide range of imaging applications is proposed and demonstrated. We derive a model for deducing the attenuation coefficients and the signal compensation value using the depth-dependent backscattering profiles, to mitigate under and overestimation in tissue imaging. We validated the method using numerical simulation and phantoms, where we achieved stable and robust compensation results over the entire depth of samples. The comparison between other attenuation characterization models and our proposed model is also performed.