A digital twin (DT) of an underground utility tunnel is valuable only if it remains synchronized with the physical asset. The objective of this study is to maintain this synchronization for an operational tunnel by automatically detecting displacements of linear and point assets, using only the fixed sensors already deployed in the tunnel. However, most DT research emphasizes design and construction, rather than operational-phase change detection. The BIM–GIS-based framework of our previous study was limited to relative-coordinate reporting, offline updating, and indoor mock-up validation. To this end, this study introduces a multimodal displacement detection framework with an automated, event-driven update workflow, which addresses these limitations and is demonstrated in an operational tunnel. Linear-object sag (power cables) is extracted from sparse, fixed fiber-scan LiDAR by adapting a recursive terrain-fragmentation ground filter into a wall-as-ground context. Point-object displacement (fire extinguishers) is detected using a single fixed CCTV camera, combining a YOLOv5 detector with a perspective transform to recover absolute coordinates in a GNSS-denied corridor and differentiate between moved and toppled assets. Detected displacements are serialized as JSON and streamed via a Kafka broker into the DT service environment, integrating heterogeneous events into a unified synchronization workflow. Field validation against a co-located survey-grade scanner confirmed agreement within the 0.10 m operational validation tolerance for nominal sags of 7, 10, and 15 cm, with the largest residual at the smallest deflection. The framework maintains the virtual model consistent with a physical tunnel without additional instrumentation, enhancing disaster prevention and response.
Industry Foundation Classes (IFC) files are the main deliverable for the digital safety management of public buildings, but a file that passes a schema check is not necessarily usable. Most checking tools reduce model quality to a single pass/fail result, blame the model for rules that do not apply or are themselves wrong, and drop the objects they could not process. We present a validation framework that keeps these questions distinct: it checks each element separately against the IFC4 schema and the project’s information requirements; reports one of seven verdict states that distinguishes model defects from inapplicable, unspecified, or defective requirements; accounts for every element so that none disappears from the audit; and labels all simplified geometry as authored or derived. Applied to eight production models from two authoring pipelines (5994 elements; 88,499 element–rule pairs), the verdicts were reproducible, agreed with an independent oracle on all 39,334 pairs it could decide, and detected eight of ten injected defect types in every case. Separating the two checks reclassified 274 valid elements of one model from violations to rule gaps, and every model from one pipeline arrived without authored axes. The framework supports procurement-side quality assurance and data-readiness screening for aging public buildings.
Fires in industrial complexes cause property damage and casualties, but the spatial conditions under which fires result in casualties are rarely assessed. This study proposes a two-stage framework that combines expert-based Analytic Hierarchy Process (AHP)–geographic information system (GIS) assessment with machine-learning feature-importance analysis of observed fires. Seven spatial indicators—four vulnerability indicators (building density, aged-building share, fire-engine access, and hazardous-facility proximity) and three reverse-coded mitigation indicators (fire-station response time, firefighting water-supply coverage, and evacuation-facility accessibility)—were defined with largely common scoring rules. In Stage 1, weights from an AHP survey of 62 experts were applied in GIS to map fire-casualty vulnerability on a 250 m grid in the Myeongji Noksan National Industrial Complex, Busan, Republic of Korea. In Stage 2, scores for the same indicators were assigned to 5417 factory fires recorded in Busan’s 41 industrial complexes during 2019–2023 (32.9% with casualties); four classifiers were trained to predict casualty occurrence, and Shapley additive explanations (SHAP) were computed for XGBoost, which achieved the highest recall (0.621). The map identified a localized high-vulnerability zone in the south-central part of the complex, where hazardous-facility proximity was concentrated, although recorded casualty fires were not clearly concentrated in these cells. SHAP ranked aged-building share and building density highest, whereas experts emphasized fire-engine access and response time. Comparing the two perspectives shows where expert emphasis and data-driven importance diverge and offers an exploratory basis for spatial prioritization and for re-examining indicator weights.