Low knee awareness after Total Knee Arthroplasty (TKA) has become the ultimate goal in trying to achieve a natural feeling knee that meet patient expectations. To accommodate this manufacturers of TKAs have developed new prosthetic designs that potentially could give patients a more natural feeling knee during activities. The purpose af this study was to compare the Forgotten Joint Score (FJS) and Oxford Knee Score (OKS) of patients treated with a previous generation standard Cruciate Retaining (CR) TKA to the scores obtained by patients treated with a newer generation CR TKA or a mobile bearing CR TKA. We identified all patients receiving a new generation CR TKA or mobile bearing TKA at our institution between 2010 and 2012. These were matched to a population of patients receiving a standard CR TKA regarding age, gender, year of surgery, Kellgren-Lawrence (KL) grade and pre- and postoperative knee alignment. Patients were asked to complete the FJS and OKS questionnaires. Of the 316 patients completing the survey 64 standard CR TKAs to 35 new generation CR TKAs and 121 standard CR TKAs to 68 mobile bearing TKAs were matched. The FJS and OKS scores of the three TKA designs were compared. When comparing the new generation CR TKAs to the standard CR TKAs we found statistically significant higher OKS and FJS scores (6 (p = 0.04) and 16 (p = 0.03) points respectively) for the new generation CR TKAs. When comparing the mobile bearing TKAs to the standard CR TKAs we found a statistically significant higher OKS score (3 points, p = 0.04), and a higher but non-significant FJS score (4 points, p = 0.48) for the mobile bearing TKAs. Patients receiving the new generation CR TKA obtained higher FJS and OKS scores when compared to patients receiving a standard CR TKA, indicating that the use of this newer prosthetic design facilitate less knee awareness and better function after TKA.
T(The Nordic Arthroplasty Register Association (NARA)
The Nordic Arthroplasty Register Association (NARA)
Uncemented fixation of THA components are increasingly used. Although cemented femoral component fixation in total hip arthroplasty has shown better results in older patients, less is known about the cup side.
Navigation-assisted and robotic systems improve component positioning in total hip (THA), total knee (TKA), and unicompartmental knee arthroplasty (UKA), but whether this improves biomaterial performance and implant survival is unclear. This structured narrative review asks for which bearing materials and fixation interfaces positioning accuracy plausibly alters the degradation and fixation pathways that govern survival, and how strong the evidence is for each link. We propose a conceptual model linking positioning to the local mechanical environment, material-specific degradation, biological response, and survival, and grade each link’s evidence by study design. Enabling technologies consistently reduce outliers. Position-dependent degradation is well documented for conventional polyethylene, ceramic-on-ceramic, and metal-on-metal bearings, mainly from simulator, retrieval, and cohort studies. Highly cross-linked polyethylene appears to attenuate the wear penalty of malposition, although rim fatigue and impingement remain position-sensitive and vitamin E stabilization has no proven additional clinical benefit. In cementless TKA, varus alignment is associated with greater early tibial migration, a validated surrogate for loosening. Clinical translation remains limited: trials and registries show no consistent reduction in all-cause revision after TKA or THA, with lower dislocation after THA and a more favorable UKA signal as exceptions. Precision may matter most for position-sensitive bearings and cementless interfaces.
Segmental bone loss after fracture-related infection (FRI) may require biological reconstruction, endoprosthetic replacement, or amputation. This narrative review examines antimicrobial management, surgical selection, and outcomes of megaprosthetic reconstruction, with emphasis on adult lower-limb periarticular defects. Evidence is distinguished as direct FRI evidence, mixed clinical evidence, or indirect evidence from oncological reconstruction and periprosthetic joint infection (PJI). Megaprostheses provide immediate structural stability and may facilitate early weight-bearing in selected patients with extensive joint involvement, limited capacity for prolonged rehabilitation, or failed biological reconstruction. However, infection, soft-tissue failure, and mechanical complications remain substantial concerns. The frequently cited PJI incidence of 15–43% comes from heterogeneous megaprosthesis populations and is not an estimate specific to reconstruction after post-traumatic FRI. Small FRI series report encouraging short-term infection control, whereas mixed and megaprosthesis PJI cohorts demonstrate recurrent infection and further salvage surgery. Staged reconstruction is commonly reported, but comparisons between surgical strategies are vulnerable to selection bias, small samples, and inconsistent outcome definitions. Biological reconstruction outcomes provide contextual benchmarks rather than evidence of comparative superiority. Overall, megaprosthetic reconstruction is a reasonable salvage option when the expected benefit of immediate stability and preservation of joint motion outweighs the risks of infection and later implant failure. Treatment should integrate adequate debridement, appropriate systemic and local antimicrobial therapy, viable soft-tissue coverage, host optimization, and shared decision-making; the available evidence does not establish a universally preferred reconstruction algorithm.