Zengding Liu

Zengding Liu


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2019 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
FMFen Miao
Fen Miao
ZLZengding Liu
Zengding Liu
JLJi-Kui Liu
Ji-Kui Liu
BWBo Wen
Bo Wen
QHQing-Yun He
Qing-Yun He
YLYe Li
Ye Li
Ambulatory blood pressure (BP) provides valuable information for cardiovascular risk assessment. The present cuff-based devices are intrusive for long-term BP monitoring, whereas cuff-less BP measurement methods based on pulse transit time or multi-parameter are inferior in robustness and reliability by using electrocardiogram (ECG) and photoplethysmogram signals. This study examined a multi-sensor fusion-based platform and algorithm for systolic BP (SBP), mean arterial pressure (MAP), and diastolic BP (DBP) estimation. The proposed multi-sensor platform was comprised of one ECG sensor and two pulse pressure wave sensors for simultaneous signal collection. After extracting 35 features from the collected signals, a weakly supervised feature selection method was proposed for dimension reduction because the reference oscillometric technique-based BP are intermittent and can be redeemed as coarse-grained labels. BP models were then established using a multi-instance regression algorithm. A total of 85 participants including 17 hypertensive and 12 hypotensive patients were enrolled. Experimental results showed that the proposed approach exhibited good accuracy for diverse population with an estimation error of 1.62 ± 7.76 mmHg for SBP, 1.53 ± 6.03 mmHg for MAP, and 1.49 ± 5.52 for DBP, which complied with the association for the advancement of medical instrumentation standards in BP estimation. Moreover, the estimation accuracy is with random daily fluctuations rather than long-term degradation through a maximum two-month follow-up period indicated good robustness performance. These results suggest that the proposed approach is with high reliability and robustness and thus provides a novel insight for cuff-less BP measurement.

19 May 2023 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Open access
ZLZengding Liu
Zengding Liu
YLYe Li
Ye Li
YZYuan-Ting Zhang
Yuan-Ting Zhang
JZJia Zeng
Jia Zeng
ZCZu-Xian Chen
Zu-Xian Chen
FMFen Miao
Fen Miao
This study aimed to evaluate the performance of cuffless blood pressure (BP) measurement techniques in a large and diverse cohort of participants. We enrolled 3077 participants (aged 18-75, 65.16% women, 35.91% hypertensive participants) and conducted followed-up for approximately 1 month. Electrocardiogram, pulse pressure wave, and multiwavelength photoplethysmogram signals were simultaneously recorded using smartwatches; dual-observer auscultation systolic BP (SBP) and diastolic BP (DBP) reference measurements were also obtained. Pulse transit time, traditional machine learning (TML), and deep learning (DL) models were evaluated with calibration and calibration-free strategy. TML models were developed using ridge regression, support vector machine, adaptive boosting, and random forest; while DL models using convolutional and recurrent neural networks. The best-performing calibration-based model yielded estimation errors of 1.33 $\pm$ 6.43 mmHg for DBP and 2.31 $\pm$ 9.57 mmHg for SBP in the overall population, with reduced SBP estimation errors in normotensive (1.97 $\pm$ 7.85 mmHg) and young (0.24 $\pm$ 6.61 mmHg) subpopulations. The best-performing calibration-free model had estimation errors of $-$ 0.29 $\pm$ 8.78 mmHg for DBP and $-$ 0.71 $\pm$ 13.04 mmHg for SBP. We conclude that smartwatches are effective for measuring DBP for all participants and SBP for normotensive and younger participants with calibration; performance degrades significantly for heterogeneous populations including older and hypertensive participants. The availability of cuffless BP measurement without calibration is limited in routine settings. Our study provides a large-scale benchmark for emerging investigations on cuffless BP measurement, highlighting the need to explore additional signals or principles to enhance the accuracy in large-scale heterogeneous populations.

5 April 2022 in Journal of the American Heart Association
Verified
Journal Article
Open access
PDF file
ZLZengding Liu
Zengding Liu
BZBin Zhou
Bin Zhou
ZJZhiming Jiang
Zhiming Jiang
XCXi Chen
Xi Chen
YLYe Li
Ye Li
FMFen Miao
Fen Miao
Background: Studies have reported the use of photoplethysmography signals to detect atrial fibrillation; however, the use of photoplethysmography signals in classifying multiclass arrhythmias has rarely been reported. Our study investigated the feasibility of using photoplethysmography signals and a deep convolutional neural network to classify multiclass arrhythmia types. Methods and Results: ECG and photoplethysmography signals were collected simultaneously from a group of patients who underwent radiofrequency ablation for arrhythmias. A deep convolutional neural network was developed to classify multiple rhythms based on 10‐second photoplethysmography waveforms. Classification performance was evaluated by calculating the area under the microaverage receiver operating characteristic curve, overall accuracy, sensitivity, specificity, and positive and negative predictive values against annotations on the rhythm of arrhythmias provided by 2 cardiologists consulting the ECG results. A total of 228 patients were included; 118 217 pairs of 10‐second photoplethysmography and ECG waveforms were used. When validated against an independent test data set (23 384 photoplethysmography waveforms from 45 patients), the DCNN achieved an overall accuracy of 85.0% for 6 rhythm types (sinus rhythm, premature ventricular contraction, premature atrial contraction, ventricular tachycardia, supraventricular tachycardia, and atrial fibrillation); the microaverage area under the microaverage receiver operating characteristic curve was 0.978; the average sensitivity, specificity, and positive and negative predictive values were 75.8%, 96.9%, 75.2%, and 97.0%, respectively. Conclusions: This study demonstrated the feasibility of classifying multiclass arrhythmias from photoplethysmography signals using deep learning techniques. The approach is attractive for population‐based screening and may hold promise for the long‐term surveillance and management of arrhythmia. Registration: URL: www.chictr.org.cn . Identifier: ChiCTR2000031170.

2 December 2018 in Sensors
Verified
Journal Article
Open access
PDF file
ZLZengding Liu
Zengding Liu
JLJi-Kui Liu
Ji-Kui Liu
BWBo Wen
Bo Wen
QHQingyun He
Qingyun He
YLYe Li
Ye Li
FMFen Miao
Fen Miao
Pulse transit time (PTT) has received considerable attention for noninvasive cuffless blood pressure measurement. However, this approach is inconvenient to deploy in wearable devices because two sensors are required for collecting two-channel physiological signals, such as electrocardiogram and pulse wave signals. In this study, we investigated the pressure pulse wave (PPW) signals collected from one piezoelectric-induced sensor located at a single site for cuffless blood pressure estimation. Twenty-one features were extracted from PPW that collected from the radial artery, and then a linear regression method was used to develop blood pressure estimation models by using the extracted PPW features. Sixty-five middle-aged and elderly participants were recruited to evaluate the performance of the constructed blood pressure estimation models, with oscillometric technique-based blood pressure as a reference. The experimental results indicated that the mean ± standard deviation errors for the estimated systolic blood pressure and diastolic blood pressure were 0.70 ± 7.78 mmHg and 0.83 ± 5.45 mmHg, which achieved a decrease of 1.33 ± 0.37 mmHg in systolic blood pressure and 1.14 ± 0.20 mmHg in diastolic blood pressure, compared with the conventional PTT-based method. The proposed model also demonstrated a high level of robustness in a maximum 60-day follow-up study. These results indicated that PPW obtained from the piezoelectric sensor has great feasibility for cuffless blood pressure estimation, and could serve as a promising method in home healthcare settings.

30 April 2024 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
ZLZengding Liu
Zengding Liu
YLYe Li
Ye Li
YZYuan-Ting Zhang
Yuan-Ting Zhang
JZJia Zeng
Jia Zeng
ZCZu-Xian Chen
Zu-Xian Chen
FMFen Miao
Fen Miao
Biosignals collected by wearable devices, such as electrocardiogram and photoplethysmogram, exhibit redundancy and global temporal dependencies, posing a challenge in extracting discriminative features for blood pressure (BP) estimation. To address this challenge, we propose HGCTNet, a handcrafted feature-guided CNN and transformer network for cuffless BP measurement based on wearable devices. By leveraging convolutional operations and self-attention mechanisms, we design a CNN-Transformer hybrid architecture to learn features from biosignals that capture both local information and global temporal dependencies. Then, we introduce a handcrafted feature-guided attention module that utilizes handcrafted features extracted from biosignals as query vectors to eliminate redundant information within the learned features. Finally, we design a feature fusion module that integrates the learned features, handcrafted features, and demographics to enhance model performance. We validate our approach using two large wearable BP datasets: the CAS-BP dataset and the Aurora-BP dataset. Experimental results demonstrate that HGCTNet achieves an estimation error of 0.9 $\pm$ 6.5 mmHg for diastolic BP (DBP) and 0.7 $\pm$ 8.3 mmHg for systolic BP (SBP) on the CAS-BP dataset. On the Aurora-BP dataset, the corresponding errors are $-$ 0.4 $\pm$ 7.0 mmHg for DBP and $-$ 0.4 $\pm$ 8.6 mmHg for SBP. Compared to the current state-of-the-art approaches, HGCTNet reduces the mean absolute error of SBP estimation by 10.68% on the CAS-BP dataset and 9.84% on the Aurora-BP dataset. These results highlight the potential of HGCTNet in improving the performance of wearable cuffless BP measurements. The dataset and source code are available at https://github.com/zdzdliu/HGCTNet.

23 May 2022 in IEEE Sensors Journal
Verified
Journal Article
Open access
YWYishan Wang
Yishan Wang
FMFen Miao
Fen Miao
QAQi An
Qi An
ZLZengding Liu
Zengding Liu
CCCong Chen
Cong Chen
YLYe Li
Ye Li
Cardiovascular disease (CVD) is a widespread disease and the leading cause of death worldwide. Home care is essential for patients with CVD, and it involves the daily monitoring of important CVD-related vital signs using methods including electrocardiography (ECG), heart rate monitoring, pulse oximetry (SpO2), and continuous blood pressure measurement. However, a wearable device that can monitor these parameters simultaneously remains unavailable; herein, we propose a lightweight, highly integrated sensor that can do so. In this sensor, an analog front end (AFE) integrated chip (IC) is implemented in the sensor to detect one-lead ECG and two-wavelength photoplethysmography (PPG) signals. The highly integrated IC minimizes both the size and power requirement of the sensor. Moreover, its comprehensive functions include adjustable gain, current compensation, lead off, and fast recovery—all of which are crucial for wearable applications in large populations. Accordingly, the sensor can apply the adaptive adjust method to automatically adjust the IC parameters to suit a range of applications and users. In addition, the heart rate is calculated from the R-R interval from the ECG signals, whereas the SpO2 is calibrated with a univariate quadratic equation with less than 1% mean error. Our sensor can also calculate the systolic blood pressure (SBP) and diastolic blood pressure (DBP) by using a support vector machine based calibration-less model with the features of infrared PPG and ECG signals. The model is trained on our pre-collected wearable dataset and has a mean error ± standard deviation of −2.10 ± 7.07 mmHg for SBP and 0.04 ± 7.34 mmHg for DBP in 16 volunteers. In conclusion, this paper reports on a multimodal, vital sign monitoring sensor—with small size, low power, and dynamic compatibility—suitable for patients with CVD under home care.