15 March 2019 in IEEE Journal of Biomedical and Health Informatics
Ambulatory blood pressure (BP) provides valuable information for cardiovascular risk assessment. The present cuff-based devices are intrusive for long-term BP monitoring, whereas cuff-less BP measurement methods based on pulse transit time or multi-parameter are inferior in robustness and reliability by using electrocardiogram (ECG) and photoplethysmogram signals. This study examined a multi-sensor fusion-based platform and algorithm for systolic BP (SBP), mean arterial pressure (MAP), and diastolic BP (DBP) estimation. The proposed multi-sensor platform was comprised of one ECG sensor and two pulse pressure wave sensors for simultaneous signal collection. After extracting 35 features from the collected signals, a weakly supervised feature selection method was proposed for dimension reduction because the reference oscillometric technique-based BP are intermittent and can be redeemed as coarse-grained labels. BP models were then established using a multi-instance regression algorithm. A total of 85 participants including 17 hypertensive and 12 hypotensive patients were enrolled. Experimental results showed that the proposed approach exhibited good accuracy for diverse population with an estimation error of 1.62 ± 7.76 mmHg for SBP, 1.53 ± 6.03 mmHg for MAP, and 1.49 ± 5.52 for DBP, which complied with the association for the advancement of medical instrumentation standards in BP estimation. Moreover, the estimation accuracy is with random daily fluctuations rather than long-term degradation through a maximum two-month follow-up period indicated good robustness performance. These results suggest that the proposed approach is with high reliability and robustness and thus provides a novel insight for cuff-less BP measurement.
19 May 2023 in IEEE Journal of Biomedical and Health Informatics
This study aimed to evaluate the performance of cuffless blood pressure (BP) measurement techniques in a large and diverse cohort of participants. We enrolled 3077 participants (aged 18-75, 65.16% women, 35.91% hypertensive participants) and conducted followed-up for approximately 1 month. Electrocardiogram, pulse pressure wave, and multiwavelength photoplethysmogram signals were simultaneously recorded using smartwatches; dual-observer auscultation systolic BP (SBP) and diastolic BP (DBP) reference measurements were also obtained. Pulse transit time, traditional machine learning (TML), and deep learning (DL) models were evaluated with calibration and calibration-free strategy. TML models were developed using ridge regression, support vector machine, adaptive boosting, and random forest; while DL models using convolutional and recurrent neural networks. The best-performing calibration-based model yielded estimation errors of 1.33 $\pm$ 6.43 mmHg for DBP and 2.31 $\pm$ 9.57 mmHg for SBP in the overall population, with reduced SBP estimation errors in normotensive (1.97 $\pm$ 7.85 mmHg) and young (0.24 $\pm$ 6.61 mmHg) subpopulations. The best-performing calibration-free model had estimation errors of $-$ 0.29 $\pm$ 8.78 mmHg for DBP and $-$ 0.71 $\pm$ 13.04 mmHg for SBP. We conclude that smartwatches are effective for measuring DBP for all participants and SBP for normotensive and younger participants with calibration; performance degrades significantly for heterogeneous populations including older and hypertensive participants. The availability of cuffless BP measurement without calibration is limited in routine settings. Our study provides a large-scale benchmark for emerging investigations on cuffless BP measurement, highlighting the need to explore additional signals or principles to enhance the accuracy in large-scale heterogeneous populations.
30 April 2024 in IEEE Journal of Biomedical and Health Informatics
Biosignals collected by wearable devices, such as electrocardiogram and photoplethysmogram, exhibit redundancy and global temporal dependencies, posing a challenge in extracting discriminative features for blood pressure (BP) estimation. To address this challenge, we propose HGCTNet, a handcrafted feature-guided CNN and transformer network for cuffless BP measurement based on wearable devices. By leveraging convolutional operations and self-attention mechanisms, we design a CNN-Transformer hybrid architecture to learn features from biosignals that capture both local information and global temporal dependencies. Then, we introduce a handcrafted feature-guided attention module that utilizes handcrafted features extracted from biosignals as query vectors to eliminate redundant information within the learned features. Finally, we design a feature fusion module that integrates the learned features, handcrafted features, and demographics to enhance model performance. We validate our approach using two large wearable BP datasets: the CAS-BP dataset and the Aurora-BP dataset. Experimental results demonstrate that HGCTNet achieves an estimation error of 0.9 $\pm$ 6.5 mmHg for diastolic BP (DBP) and 0.7 $\pm$ 8.3 mmHg for systolic BP (SBP) on the CAS-BP dataset. On the Aurora-BP dataset, the corresponding errors are $-$ 0.4 $\pm$ 7.0 mmHg for DBP and $-$ 0.4 $\pm$ 8.6 mmHg for SBP. Compared to the current state-of-the-art approaches, HGCTNet reduces the mean absolute error of SBP estimation by 10.68% on the CAS-BP dataset and 9.84% on the Aurora-BP dataset. These results highlight the potential of HGCTNet in improving the performance of wearable cuffless BP measurements. The dataset and source code are available at https://github.com/zdzdliu/HGCTNet.
4 March 2021 in IEEE Internet of Things Journal
We developed a ballistocardiography (BCG)-based Internet-of-Medical-Things (IoMT) system for remote monitoring of cardiopulmonary health. The system composes of BCG sensor, edge node, and cloud platform. To improve computational efficiency and system stability, the system adopted collaborative computing between edge nodes and cloud platforms. Edge nodes undertake signal processing tasks, namely approximate entropy for signal quality assessment, a lifting wavelet scheme for separating the BCG and respiration signal, and the lightweight BCG and respiration signal peaks detection. Heart rate variability (HRV), respiratory rate variability (RRV) analysis and other intelligent computing are performed on cloud platform. In experiments with 25 participants, the proposed method achieved a mean absolute error (MAE)±standard deviation of absolute error (SDAE) of 9.6±8.2 ms for heartbeat intervals detection, and a MAE±SDAE of 22.4±31.1 ms for respiration intervals detection. To study the recovery of cardiopulmonary function in patients with coronavirus disease 2019 (COVID-19), this study recruited 186 discharged patients with COVID-19 and 186 control volunteers. The results indicate that the recovery performance of the respiratory rhythm is better than the heart rhythm among discharged patients with COVID-19. This reminds the patients to be aware of the risk of cardiovascular disease after recovering from COVID-19. Therefore, our remote monitoring system has the ability to play a major role in the follow up and management of discharged patients with COVID-19.
29 March 2018 in IEEE Access
With increasing security and privacy requirements, electrocardiogram (ECG)-based biometric human identification and authentication is gaining extensive attention. This paper aims to solve three major problems: stable identity feature is hard extracted from the inferior quality ECG, the performance of authentication system falls down when the size of registered sample set increases, and the authentication system needs to retrain when a new registered identity is added. To improve the robustness of identity feature, this paper proposed a multiscale feature extraction method using a multiscale autoregressive model (MSARM). First, the performance of multiscale feature was tested by simple matching method based on Chi-square distance in identification system. The test was performed on self-built SIAT-ECG and public PTB databases, which contain 146 and 100 (50 healthy volunteers and 50 patients with myocardial infarction) individuals, respectively. The recognition rate exceeded 93.15% for both databases in identification scenario. The results revealed that the MSARM has more excellent performance than other feature extraction methods. Then, this paper proposed a combination classifier method with one-to-one structure in authentication mode. It yielded a true rejection rate (TRR) of 98.99% and true acceptance rate (TAR) of 95.04% when registered sample set contains 140 individuals from SIAT-ECG database. Therefore, the proposed MSARM and combination classifier not only significantly improve the accuracy but also enhance the practicability of ECG-based biometric systems.