Electrification of offshore oil and gas installations on the Norwegian continental shelf is one of several options to decrease the CO2 emitted from these installations. However, there is an ongoing debate regarding how the increased electricity consumption will influence the CO2 emissions in the power market, both in the short-run and in the long-run. This paper aims to address the issue and investigate the feasibility of the electrification of a large offshore area in the North Sea in comparison to standard concepts to supply energy offshore. A novel integrated model was developed for the purpose that includes and combines a process model of the offshore power generation units and a model of the European power system. The integration of the two models allows to simultaneously simulate the behavior of the offshore energy conversion systems and the effect of electrification on the onshore power system. The outcomes of the analysis show that the environmental performance of electrification is strongly affected by the selected approach to quantify the CO2 emissions associated with power from shore. Taking standard methods to supply offshore energy as basis for comparison, the marginal effect of electrification would result in increased CO2 emissions (+40%), while the average effect would entail large reductions in CO2 emissions (−48% to −90%), the extent of which depends on the geographical scope selected. An analysis on the economics of electrification indicates that its economic viability would be challenging and would not be favoured by a strong European commitment towards environmental policies since the expected increase of power price will outbalance the gains for the reduced emission costs.
Building integrated photovoltaics (BIPVs) have become increasingly popular in urban areas due to their potential to provide zero-emission energy in buildings. BIPVs enable the use of MO of photovoltaic (PV) modules, resulting in multiple generation peaks throughout the day, which can closely match the consumption profile of a building. However, designing a PV output power forecasting model for BIPVs can be complex, as multiple generation peaks may occur. In general, prior works focused on the design of a PV output power forecasting model and the study of the impact of tilt and azimuth angle variations on the annual yield of a PV system independently. The interaction between the two problems has received little or no attention in the literature. Considering the recent rapid development of BIPVs, it is therefore extremely important to understand this. This article, therefore, aims to quantify the impact of mixed orientations on the accuracy of a PV output prediction model for an 181.15 $\text{kW}_{p}$ BIPV system located in Trondheim, Norway. The results indicate that the mixed orientations resulted in a notable rise in forecast error, with a maximum increase of 51% in root mean squared error, when compared with a baseline model that accounted for all orientations. These findings have important implications for developing practical predictive energy management systems for BIPVs.