Demand response (DR) is a key strategy for strengthening the economic efficiency, planning and operational stability of microgrids. This paper proposes an incentive-based DR program implemented through agent-based reinforcement learning, designed to optimize the profit of both the distribution system operator and load operator, while maintaining customer comfort. Concurrently, an analytical technique ascertains the optimal size of distribution generators (DG) and their respective location by minimizing a multi-index objective comprising active loss voltage deviation, reactive power losses and MVA burden. To address the uncertainty inherent in renewable-based DGs, the beta probability distribution function (PDF) is applied for solar power and the Weibull probability function is applied for wind power uncertainty. The performance of the proposed methodology is tested on a modified IEEE 33-bus distribution system, which consists of DGs and load operators. Results demonstrate that integrating DR with optimally placed DGs leads to a 8.96% reduction in power demand, 11.74% reduction in power loss, and 8.86% reduction in total cost. Additionally, the total profit for the distribution system operator increases to $ 379.1310/day. The daily incentives earned for load reduction varied across agents. L1 received $4.8990 for cutting 181.9520 kW, while L2 earned $7.3743 for a 274.0533 kW reduction. L3 was awarded $15.6795 after decreasing usage by 492.3093 kW, and L4 gained $26.1324 for 820.5156 kW. The highest incentive, $71.8010, was awarded to L5 for curtailing 2025.6234 kW, and L6 received $39.9005 for a 1012.8211 kW reduction, based on their priority level. An analysis of the strategy’s efficacy in optimizing microgrid operational performance and financial sustainability.
The increasing penetration level of electric vehicles (EVs) shows that they will enter into the category of distributed energy sources in the near future. Major upgradation is required in the conventional power system to handle upcoming challenges due to electrification in the transportation sector and generate opportunities for the power system. The energy storage capability of batteries and advancement in fast switching converters enable EVs to support the grid with different ancillary services, e.g. primary frequency control (PFC). However, an effective charging strategy/controller is required to support the grid with PFC without violating constraints from grid and EVs. This paper proposes a novel fuzzy-based controller to decide EV’s availability for PFC with an optimized participation level considering different operational modes and EV charging demand. The controller computes the participation level of EVs based on real-time inputs from EVs, magnitude of frequency deviation and availability of primary reserve. The Spanish power system model has been employed to show the proposed controller’s efficacy and compare it with other recently reported controllers. The MATLAB/Simulink platform has been used to perform frequency and power response analysis for four different defined cases. Results show that EVs with the proposed fuzzy-based controller can effectively support the grid with PFC service without violating the grid’s and EV’s limits. GRAPHICAL ABSTRACT
An effective protection system should quickly isolate the faulty segment to avoid damage to the power system's healthy part. Directional overcurrent relays (DOCRs) are widely used as a protective device in medium and low voltage distribution systems. The DOCR operating time is a function of two parameters known as time multiplier setting (TMS) and plug setting (PS). The objective of a proper coordination scheme is to select these parameters so that the faulty section must be isolated in minimal time by corresponding primary-backup relay pairs while maintaining a minimum coordination time interval (CTI) between them. Hence, this work focuses on the optimization technique's performance in the determination of optimal relay settings to achieve proper coordination among all the relays. In this paper, a comparative analysis of relay coordination has been performed by using firefly algorithm (FA), simulated annealing (SA), charged system search algorithm (CSS), water cycle algorithm (WCA), vibrating particle search algorithm (VPSA), and grey wolf optimization (GWO) algorithm. To show the effectiveness of GWO technique, three different test cases are considered.