Ali Mardji

Prof. Dr. Ali Mardji


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021
Verified
Open access
PDF file
BTBelaid Taharou
Belaid Taharou
AMAli Mardji
Ali Mardji
RHRajshree Hillstrom
Rajshree Hillstrom
ABAli Benaissa
Ali Benaissa
SRSandipan Roy
Sandipan Roy
OMOsama Mukdadi
Osama Mukdadi
The aim of this study is to evaluate the effect of the alveolar bone quality on von Mises stress at the bone-implant interface during occlusal loading. Four (3D) finite element models of fully osteointegrated 3-mm diameter × 11.5-mm length dental implant indifferent alveolar bone with different cortical bone thickness are created, using SolidWorks computer aided design software. The alveolar bone cortical-spongy bone ratio modelled includes I) 90%-10%, II) 60%-40%, III) 40%-60%, and IV) 10%-90%. These models are then exported to ABAQUS software and stress analyses are run under an occlusal load of 70 N acting on the platform face of the dental implant. Results of this study show that the implants are subjected to similar stress distributions in all models; maximum stress values are confined in the outer cervical plate of the cortical bone around the neck. This could explain bone loss and implant de-osseointegration. Peak stresses are lowest in the model with 90% cortical bone (14.2 MPa) and almost doubled in the model with 10% cortical bone (26.6 MPa). The stress values gradually reduce towards the apical area, demonstrating masticatory force transfer from implant to bone. Furthermore, both cortical and spongy bone structures exhibit highest stress values in the model with thinnest cortical layer. The high interfacial stress concentration near the implant-cortical bone junction could lead to bone failure or implant instability induced by fatigue or overload risk. Results of our study could be a first step towards the development of a clinical pre-operative planning tool for dental implantolgy.

1 June 2018 in Journal of Biomimetics, Biomaterials and Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
ABAmel Boukhlif
Amel Boukhlif
AMAli Mardji
Ali Mardji
NDNoureddine Della
Noureddine Della
ECEl Bahri Ould Chikh
El Bahri Ould Chikh
OMOsama Mukdadi
Osama Mukdadi
RHRajshree Hillstrom
Rajshree Hillstrom
The number of supporting dental implants is an important criterion for the surgical outcome of dental bridge fixation, which has considerable impact on biomechanical load transfer characteristics. Excessive stress at the bone–implant interface by masticatory loading may result in implant failure. The aim of this study was to evaluate the impact of the number of implants supporting the dental bridge on stress in neighboring tissues around the implants. Results of the study will provide useful information on appropriate surgical techniques for dental bridge fixation. In this study, osseointegrated smooth cylindrical dental implants of same diameter and length were numerically analyzed, using three-dimensional bone–implant models. The effect of the number of supporting implants on biomechanical stability of dental bridge was examined, using two, three and four supporting implants. All materials were assumed to be linearly elastic and isotropic. Masticatory load was applied in coron-apical direction on the external part of dental bridge. Finite Element (FE) analyses were run to solve for von Mises stress. Maximum von Mises stresses were located in the cervical line of cortical bone around dental implants. Peak von Mises stress values decreased with an increase in the number of implants that support the dental bridge. Results of this study demonstrate the importance of using the correct number of supporting implants to for dental bridge fixation.

13 March 2023 in Journal of Engineering and Science in Medical Diagnostics and Therapy
Verified
Journal Article
Closed access
PDF file
ZYZhongxiao Yuan
Zhongxiao Yuan
PCPerk Lin Chong
Perk Lin Chong
SRSandipan Roy
Sandipan Roy
AMAli Mardji
Ali Mardji
AOABDELHAK OULDYEROU
ABDELHAK OULDYEROU
OMOsama M. Mukdadi
Osama M. Mukdadi

4 January 2012
Verified
Book Chapter
Closed access
PDF file
AMAli Mardji
Ali Mardji
BBBel Abbes Bachir Bouiadjra
Bel Abbes Bachir Bouiadjra
RMRajshree Mootanah
Rajshree Mootanah
BSBoualem Serier
Boualem Serier
TATarik Achour
Tarik Achour
NDNoreddine Djebbar
Noreddine Djebbar

28 October 2026 in Polymers
Verified
Journal Article
Open access
PDF file
AAAysun Akpınar
Aysun Akpınar
HÇHalil Çelik
Halil Çelik
MKMehmet Kilinc
Mehmet Kilinc
Zeynep Ceren CELIKZeynep Ceren CELIK
Zeynep Ceren CELIK
AMAli Mardji
Ali Mardji
SRSandipan Roy
Sandipan Roy
Surface coating may influence the physicochemical and mechanical properties of surgical sutures. This study was conducted to characterize the changes associated with a humic-acid-containing alginate coating applied to silk and poly(glycolide-co-lactide) (PGLA) sutures in two sizes (3-0 and 4-0). Untreated sutures served as controls. Surface-related spectral changes were examined using Fourier-transform infrared (FTIR) spectroscopy, while mechanical properties were evaluated via tensile testing in accordance with EN ISO 2062. Maximum tensile force and elongation at break were recorded. FTIR analysis revealed changes in the intensity and breadth of selected absorption bands, particularly those associated with O–H and C=O groups, after the coating was applied. These findings indicated treatment-associated spectral changes but did not independently confirm humic acid incorporation or coating stability. The maximum tensile force was lower in treated silk sutures than in untreated controls for both size 3-0 (22.6 ± 3.68 N vs. 17.8 ± 1.35 N; p = 0.140) and size 4-0 (12.8 ± 1.21 N vs. 10.6 ± 2.56 N; p = 0.276), although neither difference was statistically significant. For PGLA sutures, no statistically significant difference was observed for size 3-0 (27.7 ± 2.80 N vs. 27.6 ± 2.56 N; p = 0.966). In contrast, the size 4-0 PGLA sutures exhibited a higher maximum tensile force following treatment (14.2 ± 1.85 N vs. 21.1 ± 2.45 N; p = 0.021). Elongation at break increased in the treated size 3-0 silk sutures (16.0 ± 0.91% vs. 20.3 ± 1.10%; p = 0.007) and decreased in the treated size 4-0 silk sutures (19.3 ± 1.26% vs. 14.8 ± 1.75%; p = 0.027). No statistically significant differences in elongation were found for size 3-0 PGLA (32.1 ± 1.16% vs. 28.4 ± 2.21%; p = 0.082) or size 4-0 PGLA sutures (31.4 ± 1.88% vs. 30.8 ± 1.24%; p = 0.672). These preliminary findings indicate that the humic-acid-containing alginate coating procedure was associated with spectral changes and different mechanical responses in silk and PGLA sutures.