This paper presents the final development of an expert system utilizing a measurement of cable screen earthing transient current. The developed system allows for identification and location of earth fault in underground cable and mixed lines (underground cable and overhead line) and monitoring of an earthing system and cable screen connections. The unique feature of the developed earth fault locating system is the possibility of identification of line type and branch of the MV underground cable or mixed feeder under earth fault conditions. As a result, the time to remove failure can be greatly reduced and the number of earth fault indicators installed in the distribution network can also be reduced. Unfortunately, in order to operate properly, the previously developed system requires a fundamental—50 Hz component of the measured zero-sequence cable core current and cable screen earthing current; therefore, short transient earth faults without steady-state earth fault currents cannot be localized and categorized even though the transient earth faults have a negative impact on the power system. According to measurements performed by the authors, transient earth faults are relatively frequent, which causes stress to insulation. The number of transient earth faults may be reduced by ensuring proper maintenance of the distribution system. Unfortunately, because of the very large area of the distribution feeder, often in the range of tens of kilometers or even around a hundred kilometers, and many potential causes of earth faults, it is very difficult to localize the transient earth fault and determine the cause of the earth fault. Herein, we present the possible causes of transient earth faults and methods developed for the analysis of transient earth faults. Moreover, the novel algorithm for transient earth fault detection and location is proposed. The proposed algorithm has a self-learning capability and can identify branches of the distribution feeder under transient earth fault conditions. The effectiveness of the proposed algorithm is confirmed thanks to the performed network experiment.
This paper presents novel zero sequence current filter and earth fault protection relay, which utilize cable screens earthing current in protection algorithm. Different problems connected with state of the art of zero sequence current filters and protection relays are presented and compared with the proposed solution. The presented concept is verified in PowerFactory simulation software, experiment concerning modeling the earth fault current flow in medium voltage (MV) cable supplied from the low voltage (LV) network and measurements in the MV network in the Polish distribution system. The proposed solution is characterized by higher sensitivity and reduced number of erroneous trips. The presented solution is suitable for any MV cable lines. Biggest advantages are observed in power output lines from renewable energy sources, which are often operated under no-load conditions.
Rail is the most efficient and low carbon means of transport, but efforts are still being made to improve the energy efficiency of this sector. In Poland, one of the elements of the implementation of the energy transformation in rail is the “Green Railway” program, which assumes an increase in the share of renewable energy sources (RES) in the power supply structure of the sector to 50% in 2025 and 85% in 2030, and ultimately, to 100%. An increase in energy efficiency leads to a reduction in financial costs, and also contributes to improving the environment and, consequently, to enhancing the economic and social benefit through a cost–benefit analysis. Energy consumption in railway operations is characterized (unlike in construction) by being repetitive. This energy consumption is produced in four areas: in the movement of trains; in auxiliary systems in the trains; in auxiliary systems in the infrastructure (lighting consumption of tunnels or sections of track, point heating systems, the signaling and communication systems, etc.); and in stations, workshops and by other consumers. The aim of this article was to review modern technologies using renewable energy sources in rail transport for traction and non-traction customers.
This paper presents current flow in cable screens and a cable screen earthing system. Moreover, the paper presents the methodology for the detection of problems in cable screens, such as open phase in a cable screen and high contact resistance of a cable screen in a cable joint. The is based on cable screen current measurements and allows for localization of the erroneous connection–high contact resistance or open phase. The phenomenon is simulated in PowerFactory Software. Moreover, exemplary cable screen current measurements are presented.
The paper presents the possibility of using cable screen earthing current measurements for MV, single-core cable line monitoring. Cable screen earthing current measurement allows the condition of cable screen connections, degradation of earthing systems, and the earthing system integrity to be observed, which allows a condition based maintenance (CBM) strategy to be introduced for cable screens and earthing systems in MV networks. CBM allows the workload and failure rate to be reduced. Analysis of the condition of the cable screen and earthing system is carried out based on the cable screen earthing current trends and rapid changes of the current. The proposed system is integrated with a state of the art advanced metering infrastructure (AMI) and uses AMI data to calculate currents flowing through cable segments of the analyzed feeder. Additionally, a system which counts thermo-mechanical stresses associated with high current incidents in cable screens is proposed. The stresses are assessed using data from conventional protection relays and the ratio of currents in the cable core and cable screens. The stresses can be used as an indicator of the cable joint condition. The presented phenomena are studied carefully in PowerFactory software. Theoretical considerations are confirmed using measurements taken in the real MV cable line. Finally, the results of a SWOT analysis are presented and future research activities are outlined.
The paper analyzes the utilization of cable screen currents for earth fault identification and location. Attention is paid on cable and mixed feeders—cable and overhead lines. The principle of operation is based on utilization of 3 criterion values: Ratio of cable screen earthing current and zero sequence cable core current—RF110/15, phase shift between cable screen earthing current and zero sequence cable core current—α and cable screen admittance defined as a ratio of cable screen earthing current and zero sequence voltage—Y0cs. Earth fault location is possible thanks to discovered relation between RF110/15 and α, whereas Y0cs allows for reliable detection of earth faults. Detection and identification are very important because it allows to increase the reliability of supply—reduce downtime and number of consumers affected by the fault. The article presents a phase to ground fault current flow for different power system configurations. At the end solution, which improves location capabilities is proposed. The solution is analyzed in PSCAD software and verified by network experiment.