Valeriy Kuznetsov

Prof. Dr. Valeriy Kuznetsov

Electric Power Department, Railway Research Institute, Warsaw, Poland
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2021 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
VCVolodymyr Chenchevoi
Volodymyr Chenchevoi
VKValeriy Kuznetsov
Valeriy Kuznetsov
VKVitalii Kuznetsov
Vitalii Kuznetsov
OCOlga Chencheva
Olga Chencheva
IZIurii Zachepa
Iurii Zachepa
SLSerhii Levchenko
Serhii Levchenko
The paper presents studies of the system "induction generator-induction motor" with parametric asymmetry on a mathematical model to determine the quality of generated electricity in load operating modes. A mathematical model of the "induction generator-induction motor" system has been developed taking into account losses in steel and parametric asymmetry. The analysis of the transient characteristics of an induction generator when a motor load is connected in symmetrical and asymmetrical modes of operation is carried out. The results of changes in the main characteristics of an induction motor at various degrees of parametric asymmetry in the generator are presented. The quality of the generated electricity was analyzed based on the calculations of the unbalance coefficients for each of the operating modes. The assessment of the thermal state in steady-state conditions was carried out using an equivalent thermal equivalent circuit. Thermal transients were investigated when starting an induction motor from an autonomous energy source based on an induction generator. On a thermal mathematical model, the study of the effect of the output voltage asymmetry on the heating of the connected induction motor was carried out. It is shown that the asymmetry of the output voltage of an induction generator reaches 3–10 % and causes overheating of the windings in excess of the permissible values. A regression model has been developed for studying the operating conditions of an induction motor when powered by an induction generator with an asymmetry of the stator windings. The use of the obtained equations will make it possible to determine the most rational combination of factors affecting the heating of the stator windings of induction machines, in which they will not overheat above the maximum permissible temperature values of the corresponding insulation classes

1 April 2021 in Journal of Ecological Engineering
Verified
Journal Article
Open access
YZYuliia Zelenko
Yuliia Zelenko
MBMaryna Bezovska
Maryna Bezovska
VKValeriy Kuznetsov
Valeriy Kuznetsov
AMAntonina Muntian
Antonina Muntian
Processing of metals by cutting under modern conditions becomes impossible without the use of effective cutting fluids. The main purpose of cutting fluids is cooling, lubrication of the workpiece processing area. Spent emulsion is a special type of wastewater, very dangerous to the environment,...

19 January 2024 in Energies
Verified
Journal Article
Open access
PDF file
VKValeriy Kuznetsov
Valeriy Kuznetsov
PHPetro Hubskyi
Petro Hubskyi
ARArtur Rojek
Artur Rojek
MUMagdalena Udzik
Magdalena Udzik
Krzysztof LowczowskiKrzysztof Lowczowski
Krzysztof Lowczowski
Rail is the most efficient and low carbon means of transport, but efforts are still being made to improve the energy efficiency of this sector. In Poland, one of the elements of the implementation of the energy transformation in rail is the “Green Railway” program, which assumes an increase in the share of renewable energy sources (RES) in the power supply structure of the sector to 50% in 2025 and 85% in 2030, and ultimately, to 100%. An increase in energy efficiency leads to a reduction in financial costs, and also contributes to improving the environment and, consequently, to enhancing the economic and social benefit through a cost–benefit analysis. Energy consumption in railway operations is characterized (unlike in construction) by being repetitive. This energy consumption is produced in four areas: in the movement of trains; in auxiliary systems in the trains; in auxiliary systems in the infrastructure (lighting consumption of tunnels or sections of track, point heating systems, the signaling and communication systems, etc.); and in stations, workshops and by other consumers. The aim of this article was to review modern technologies using renewable energy sources in rail transport for traction and non-traction customers.

3 January 2022 in Energies
Verified
Journal Article
Open access
PDF file
VKValeriy Kuznetsov
Valeriy Kuznetsov
EKEwa Kardas-Cinal
Ewa Kardas-Cinal
Piotr GołębiowskiPiotr Gołębiowski
Piotr Gołębiowski
BLBorys Liubarskyi
Borys Liubarskyi
MGMagomedemin Gasanov
Magomedemin Gasanov
MOMichał Opala
Michał Opala
One of the assumptions made during the modernization process of diesel shunting locomotives is the replacement of a diesel traction motor with a DC generator with an electric asynchronous traction motor. The article aimed to develop a method of selecting energy-efficient parameters of an asynchronous electric traction motor for diesel shunting locomotives, which will ensure that its operating energy efficiency will be as high as possible. The method was verified on the example of a locomotive series ChME3 (ЧMЭ3, ČME3, ČKD S200). It has been found that using a traction asynchronous electric drive on a ChME3 locomotive, its efficiency increases in comparison with DC electric motors by 3–5% under the long-term operation modes and by 7–10% during locomotive operation with traction at the adhesion limit. Using a new traction gearbox with a higher gear ratio expands the speed range in which the asynchronous traction drive operates with a high-efficiency factor. It is effective to use a traction asynchronous electric drive to modernize ChME3 diesel locomotives in case of their use under the modes requiring the implementation of maximum traction forces at low speeds. A further increase in the efficiency of the traction asynchronous electric drive is possible based on the optimal design of the wheel-motor unit and the asynchronous traction electric drive.

30 December 2020 in Archives of Transport
Verified
Journal Article
Closed access
VKValeriy Kuznetsov
Valeriy Kuznetsov
BLBorys Lyubarskyi
Borys Lyubarskyi
EKEwa Kardas-Cinal
Ewa Kardas-Cinal
BYBagish Yeritsyan
Bagish Yeritsyan
IRIevgen Riabov
Ievgen Riabov
IRIvan Rubanik
Ivan Rubanik
Shunting is an integral part of the partial process. In 1520 mm gauge countries, shunting operations are performed by outdated locomotives, which are being replaced by modern models; the technical parameters best match the conditions of the shunting work performed. The article analyzes recommendations for the selection of parameters of shunting locomotives and the actual indicators of their work. On the basis of this analysis, a requirement was made on the necessity of compulsory consideration of the operating conditions of the locomotive when determining its technical characteristics. As the main technical parameters of shunting locomotives, the tractive power and starting tractive force are taken and their influence on the duration of an elementary shunting movement of the "acceleration-deceleration" type is investigated. This approach advises the regulatory documentation for the organization of shunting work. Tha developed mathematical model allows to carry out research on the influence of tractive power and starting tractive force on the time of acceleration and deceleration. Calculations of the time of the train's acceleration are carried out with varying their mass and the slope of the track at different values of the tractive power starting tractive force. The calculations were carried out for the mass of compositions 1000...5000 Mg for the profile slopes equal to 0 and 1.5 ‰. The speed of the finish of acceleration was taken equal to 15 and 25 km/h. The thrust starting tractive force varied in the range of 150...300 kN, the tractive power - 200 ... 1100 kW. According to the results of calculations, it was found that the reduction in the duration of the elementary shunting movement is more significantly affected by the power of the locomotive than by the starting traction force. The “saturation” effect was noted, in which a significant increase in power or traction force during starting does not cause a significant reduction in the acceleration time. In this regard, for shunting locomotives with AC traction drive, it is recommended to take a pulling force of an equal continuous traction force.

19 May 2020 in Diagnostyka
Verified
Journal Article
Open access
MTMykola Tryputen
Mykola Tryputen
VKVitalii Kuznetsov
Vitalii Kuznetsov
VKValeriy Kuznetsov
Valeriy Kuznetsov
YKYevheniia Kuznetsova
Yevheniia Kuznetsova
MTMaksym Tryputen
Maksym Tryputen
AKAlisa Kuznetsova
Alisa Kuznetsova
The paper represents laboratory bench to analyze a system of automated control with a fuzzy controller. The laboratory bench consists of a thermal object, and software and hardware complex involving logic controller VIPA System 200 V as well as HMI/SCADA system Zenon Supervisor 7.0. The thermal...