Oskar Weiland

Mr. Oskar Weiland

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2023 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
TKT. Krenz
T. Krenz
OWOskar Weiland
Oskar Weiland
PTPatrick Trinke
Patrick Trinke
LHL. Helmers
L. Helmers
CEC. Eckert
C. Eckert
RHRichard Hanke-Rauschenbach
Richard Hanke-Rauschenbach
In this work temperature inhomogeneities and their influence on PEMWE performance of industrial-scale stacks are investigated. Three temperature differences are examined: (i) between the inlet and outlet, (ii) in-between the cells of a stack, (iii) between the cell’s solid materials and the fluids. A validated stack model for temperature and performance is presented which is used to quantify the above-mentioned temperature fields and their influences on current density distribution and cell voltages. For a chosen scenario, with current densities of 2.0 A cm−2, fluid inlet temperatures of 60 °C and flow-rates of 0.15 kg s−1m−2, peak temperature differences amount to 8.2 K along-the-channel. This relates to inhomogeneities of current density of up to 10% inside a cell and deviations of cell voltage of 9 mV in-between cells in the center of the stack and outer cells. For higher current densities these differences increase further. More homogeneous temperatures allow operation at elevated average temperatures without exceeding temperature limitations and reduce the spread of degradation mechanisms. Hence, homogenous profiles lead to a more hole-some utilization of electrolysis stacks. Therefore, the ability to homogenize via alternative operation such as higher flow-rate, higher pressure and altered routing of fluid-flow is analyzed.

1 May 2023 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
OWOskar Weiland
Oskar Weiland
PTPatrick Trinke
Patrick Trinke
BBBoris Bensmann
Boris Bensmann
RHRichard Hanke-Rauschenbach
Richard Hanke-Rauschenbach
This work analyses the water transport and ionic losses in bipolar membranes at water electrolysis cells conditions. In common bipolar setups, water is split at the bipolar interface between the anion exchange membrane (AEM) and the cation exchange membrane (CEM). Accordingly, ions (protons and hydroxide ions) are transported to the electrodes, carrying the water out of both membranes via electro-osmotic drag. These outfluxes plus the required water amount for the splitting process have to be compensated by water diffusion towards the bipolar interface. The effect of water transport on the polarisation behaviour is additionally shown. Mayerhöfer et al. [ACS Appl. Energy Mater., 3, 9635 (2020)] and Oener et al.[ACS Energy Lett., 6, 1 (2021)] decreased polarization losses and increased the current density range by reducing either the AEM or the CEM thickness, respectively. Our model validates these improvements by calculating the limiting current density caused by dehydration of the membranes. Further analysis shows that thinner AEM thicknesses decrease membrane voltage losses more than thinner CEM due to lower ionic conductivities and faster dehydration of AEMs. Thin CEMs on the other hand, are more efficient at increasing the limiting current density.

8 January 2026 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
OWOskar Weiland
Oskar Weiland
LSLukas Stein
Lukas Stein
PTPatrick Trinke
Patrick Trinke
BBBoris Bensmann
Boris Bensmann
RHRichard Hanke-Rauschenbach
Richard Hanke-Rauschenbach
The efficiency of polymer electrolyte membrane water electrolysis is influenced by the design of the flow field (FF), which governs fluid distribution, pressure balance, and mechanical contact. Homogeneous mechanical compression is required to obtain effective contact between the anodic porous transport layer (aPTL) and the anodic catalyst layer (aCL), thereby ensuring efficient utilization of the catalyst‑coated membrane (CCM). By testing ten distinct FF designs, including rib‑channel, planar, meander, and block geometries, in a common cell configuration, we find that the performance spread is dominated by variations in high‑frequency resistance (HFR). These HFR differences arise mainly from inhomogeneous cell compression, an effect that becomes pronounced for wide‑channel geometries. Therefore, we evaluate three design strategies to restore high performance with wide‑channel FFs: (i) platinized aPTLs to improve the aPTL‑aCL electrical interface; (ii) stiff Ti‑fiber PTLs on the cathodic side (cPTL) to increase rigidity and homogenize the local mechanical pressure; and (iii) a planar cathodic FF geometry, which likewise homogenizes the mechanical pressure distribution.

12 June 2026 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
OWOskar Weiland
Oskar Weiland
LSLukas Stein
Lukas Stein
EBEric Beaulieu
Eric Beaulieu
LPLuis Padilla
Luis Padilla
AKAndré Koch
André Koch
RHRichard Hanke-Rauschenbach
Richard Hanke-Rauschenbach
Reducing the iridium loading of catalyst‑coated membranes (CCMs) is a prerequisite for lowering proton exchange membrane (PEM) water electrolyzer’s capital cost and facilitate its large‑scale deployments. However, the effects of cell‑clamping pressure and microporous layer (MPL) incorporation on the performance of low iridium loading (LL) electrolyzers is not yet fully understood. CCMs with a 4 cm 2 active area and varying iridium loadings (0.78, 0.26, 0.11 mg IrOx cm −2 ) were prepared and tested under clamping pressures ranging from 1 to 6 MPa. The high‑frequency resistance (HFR) of the high‑loading CCM showed only a modest clamping pressure dependence. In contrast, the LL CCM exhibited both high HFR values and a strong sensitivity to compression. A clamping pressure of 2–4 MPa is needed to achieve good performance. Introducing an MPL to the LL configuration substantially reduced the cell voltage, primarily by lowering the HFR at low clamping pressures. An optimal clamping pressure of around 2 MPa provided a trade-off where lower pressure led to increasing HFR and higher compression resulted in increased transport losses for the MPL setup. These findings show that the application of moderate compression combined with an MPL can achieve high performance with low iridium CCMs in PEM water electrolysis.

24 November 2025 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
OWOskar Weiland
Oskar Weiland
LSLukas Stein
Lukas Stein
LPLuis Padilla
Luis Padilla
PTPatrick Trinke
Patrick Trinke
BBBoris Bensmann
Boris Bensmann
RHRichard Hanke-Rauschenbach
Richard Hanke-Rauschenbach
Reducing the anodic loading of the catalyst-coated membrane (CCM) is necessary for upscaling low-cost PEM electrolyzers. Various studies show that good cell performance is attainable with low-loading CCMs. 1 For this, effective electrical contact between the anodic porous transport layer and CCM is necessary to increase CCM utilization, as electric in-plane conduction inside the catalyst layer is reduced. 2, 3 The cell clamping pressure and mechanical pressure distribution affect the electric contact between the anodic porous transport layer and the catalyst layer. 4 The impact of the cell clamping pressure on low-loading CCMs is shown in this work. Anodic loadings of the CCM, varied down to 0.11 mg/cm², are electrochemically characterized, with particular emphasis on the effects of varying clamping pressure. Also, different porous transport layers and flow fields are applied to study the impact of the cell setup on the overall cell performance. The clamping pressure is gradually increased from 1 MPa to 6 MPa and post mortem SEM images are recorded. A 2D CCM model is used to explain the results from the electrochemical characterization. Both kinetic and ohmic losses are affected by the IrOx-loading. The exchange current density varies with the loading but appears to be relatively insensitive to the clamping pressure. The HFR, on the other hand, appears to be higher and more sensitive to the clamping pressure with decreased loadings (Fig. 1a). Increased HFR values can be explained by inhomogeneous CCM utilization, mostly due to low electric in-plane aCL conductivity. References [1] C. Wang, K. Lee, C. P. Liu, D. Kulkarni, P. Atanassov, X. Peng and I. V. Zenyuk, International Materials Reviews, 69 (1), 3–18 (2024). [2] E. Padgett, G. Bender, A. Haug, K. Lewinski, F. Sun, H. Yu, D. A. Cullen, A. J. Steinbach and S. M. Alia, J. Electrochem. Soc., 170 (8), 84512 (2023). [3] M. F. Ernst, V. Meier, M. Kornherr and H. A. Gasteiger, J. Electrochem. Soc., 171 (7), 74511 (2024). [4] A. Martin, P. Trinke, M. Stähler, A. Stähler, F. Scheepers, B. Bensmann, M. Carmo, W. Lehnert and R. Hanke-Rauschenbach, J. Electrochem. Soc., 169 (1), 14502 (2022). The authors gratefully acknowledge funding by BMBF in the framework of project DERIEL, FKZ 03HY122G, and NEO-PEM-KLX, FKZ 03SF0762A, as well as André Koch and the Solar Energy Research Hamelin (ISFH) for recording the SEM images. Figure 1