Luis Padilla Urbina

Luis Padilla Urbina

Auto-generated profile, based on publicly available information

Luis Padilla Urbina

University of Alberta

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2023 in Journal of Power Sources
Verified
Journal Article
Closed access
LUL. Padilla Urbina
L. Padilla Urbina
JLJ. Liu
J. Liu
NSNatalia Semagina
Natalia Semagina
Marc SecanellMarc Secanell
Marc Secanell

1 October 2024 in Chemical Engineering Journal
Verified
Journal Article
Open access
LPL. Padilla
L. Padilla
JLJ. Liu
J. Liu
NSNatalia Semagina
Natalia Semagina
Marc SecanellMarc Secanell
Marc Secanell

1 May 2020 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
AKAslan Kosakian
Aslan Kosakian
LULuis Padilla Urbina
Luis Padilla Urbina
AHAidan Heaman
Aidan Heaman
Marc SecanellMarc Secanell
Marc Secanell
Cost of hydrogen-fueled proton-exchange-membrane fuel cells (PEMFCs) remains a challenge for the global commercialization of the technology and needs to be reduced to meet the U.S. Department of Energy goals [1]. Cost-reduction can be achieved by incorporating efficient water management, which helps keep the electrolyte hydrated while avoiding cell flooding by product water. Dynamic liquid-water accumulation and electrolyte hydration can be studied via transient polarization [2-6] and ohmic-resistance [2,4-7] curves, in which they induce hysteresis. Analyzing the polarization and resistance data may, however, be challenging due to the overlapping transients of various physical processes occurring in the cell during the voltage and current sweeps. Electrochemical impedance spectroscopy (EIS) allows the study of the dynamic processes of different time scales separately in the frequency domain and has been widely used for fuel-cell characterization [8-11]. Fuel-cell impedance spectra often exhibit an inductive behavior at low frequencies, which has been shown to be affected by electrolyte hydration [10,12-14]. A recent experimental study [9] showed that the strength of this inductive behavior depends on the anode and cathode RH. Understanding the low-frequency inductance may help improve the water-management strategies for fuel cells. However, this inductive phenomenon has not been investigated in detail with a comprehensive numerical model. In this work, a transient 2D PEMFC model is developed in the open-source fuel-cell modeling software OpenFCST [17] with a thorough validation through dynamic polarization, resistance, and impedance-spectroscopy data at various operating conditions. Unlike other physical EIS models [13-16], the presented model does not rely on parameter fitting to reproduce the experimental impedance spectra. The model also takes the finite-rate water absorption/desorption kinetics of the electrolyte into account, which allows to investigate the effect of the interfacial transport of water on fuel-cell impedance and performance. With the presented model, water-management signatures are identified in fuel-cell impedance spectra under single-phase conditions that help elucidate electrolyte-hydration dynamics. The trends in the simulated effect of anode and cathode RH on the fuel-cell inductance are in agreement with experiments in [9], which verifies the model’s ability to correctly predict the inductive behavior. The low-frequency inductive behavior of fuel cells is shown to be related to the interfacial transport of water in the electrolyte and linked to the electrolyte-hydration and proton-conductivity dynamics in the membrane and in the catalyst layers. Additionally, an ohmic-resistance breakdown is performed with the model using the ohmic-heating-based approach proposed by Secanell et al. [18]. The high-frequency resistance obtained through EIS is shown to be comprised of the membrane resistance and the electronic resistance of other MEA components, but not the protonic resistance of the catalyst layers. Figure: Single-phase water-transport signatures in a fuel-cell-impedance spectrum. References [1] D. Papageorgopoulos. Fuel Cell R&D Overview. U.S. Department of Energy; 2019. [2] C. Ziegler et al. J. Electrochem. Soc. 152.8 (2005): A1555-A1567. [3] H. Yu and C. Ziegler. J. Electrochem. Soc. 153.3 (2006): A570-A575. [4] D. Gerteisen et al. J. Power Sources 187.1 (2009): 165-181. [5] L. Hao et al. J. Power Sources 177.2 (2008): 404-411. [6] J. Hou. Int. J. Hydrogen Energ. 36.12 (2011): 7199-7206. [7] A. Goshtasbi et al. J. Electrochem. Soc. 166.7 (2019): F3154-F3179. [8] D. Malevich et al. J. Electrochem. Soc. 156.2 (2009): B216-B224. [9] A. Schiefer et al. EFCF 2019: Low-Temperature Fuel Cells, Electrolisers, & H2 Processing, Chapter 03 (2019): 179–189. [10] I. Pivac and F. Barbir. J. Power Sources 326 (2016): 112-119. [11] S. M. R. Niya and M. Hoorfar. J. Power Sources 240 (2013): 281-293. [12] B. P. Setzler and T. F. Fuller. J. Electrochem. Soc. 162.6 (2015): F519-F530. [13] C. Bao and W. G. Bessler. J. Power Sources 278 (2015): 675-682. [14] G. A. Futter et al. J. Power Sources 391 (2018): 148-161. [15] A. Baricci et al. Fuel Cells 14.6 (2014): 926-937. [16] J. R. Vang et al. ECS Transactions 68.3 (2015): 13-34. [17] M. Secanell et al. ECS Transactions 64.3 (2014): 655-680. [18] M. Secanell et al. ECS Transactions 69.17 (2015): 157-187. Figure 1

1 January 2022 in SSRN Electronic Journal
Verified
Preprint
Open access
PDF file
YKYongwook Kim
Yongwook Kim
LULuis Padilla Urbina
Luis Padilla Urbina
TATristan Asset
Tristan Asset
Marc SecanellMarc Secanell
Marc Secanell
PAPlamen Atanassov
Plamen Atanassov
JGJeff Gostick
Jeff Gostick
Non-precious group metal (non-PGM) catalysts offer the opportunity to significantly reduce fuel cell costs. However, owing to its low volumetric activity, non-PGM electrodes are made an order of magnitude thicker than platinum-based electrodes. Thicker electrodes increase transport losses making it critical to optimize electrode composition. In most studies, non-PGM electrodes are tested with fully humidified O2/air to maximize the proton conductivity. However, the fully humidified inlet gas makes non-PGM electrodes more prone to water flooding which can cause long-term performance degradation. In the present study, a single-phase, non-isothermal model was used to investigate the structure-performance relationships of the non-PGM electrodes operated at low relative humidity. Our modeling study reveals that high porosity is not necessarily required for non-PGM electrodes operating at low relative humidity. Instead, high solid and electrolyte phase volume fractions are desired. Our proposed strategy is to reduce the thickness of the non-PGM electrode while keeping the mass loading of the non-PGM catalyst consistent.

12 June 2026 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
OWOskar Weiland
Oskar Weiland
LSLukas Stein
Lukas Stein
EBEric Beaulieu
Eric Beaulieu
LPLuis Padilla
Luis Padilla
AKAndré Koch
André Koch
RHRichard Hanke-Rauschenbach
Richard Hanke-Rauschenbach
Reducing the iridium loading of catalyst‑coated membranes (CCMs) is a prerequisite for lowering proton exchange membrane (PEM) water electrolyzer’s capital cost and facilitate its large‑scale deployments. However, the effects of cell‑clamping pressure and microporous layer (MPL) incorporation on the performance of low iridium loading (LL) electrolyzers is not yet fully understood. CCMs with a 4 cm 2 active area and varying iridium loadings (0.78, 0.26, 0.11 mg IrOx cm −2 ) were prepared and tested under clamping pressures ranging from 1 to 6 MPa. The high‑frequency resistance (HFR) of the high‑loading CCM showed only a modest clamping pressure dependence. In contrast, the LL CCM exhibited both high HFR values and a strong sensitivity to compression. A clamping pressure of 2–4 MPa is needed to achieve good performance. Introducing an MPL to the LL configuration substantially reduced the cell voltage, primarily by lowering the HFR at low clamping pressures. An optimal clamping pressure of around 2 MPa provided a trade-off where lower pressure led to increasing HFR and higher compression resulted in increased transport losses for the MPL setup. These findings show that the application of moderate compression combined with an MPL can achieve high performance with low iridium CCMs in PEM water electrolysis.