Carlos Hiram Rojas García

Dr. Carlos Hiram Rojas García

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2013 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JNJoaquin G. Norniella
Joaquin G. Norniella
José M. CanoJosé M. Cano
José M. Cano
GOGonzalo Alonso Orcajo
Gonzalo Alonso Orcajo
CGCarlos Hiram Rojas García
Carlos Hiram Rojas García
JPJoaquin Francisco Pedrayes
Joaquin Francisco Pedrayes
MMManuel G. Melero
Manuel G. Melero
Virtual flux (VF)-oriented control (VFOC) and VF-based direct power control (DPC) (VF-DPC) have been developed to improve voltage-oriented control and DPC of three-phase active rectifiers. The VF space vector is utilized in transformations between stationary and rotating coordinates in VFOC and in obtaining instantaneous power in VF-DPC. The VF space vector is calculated by integrating the grid voltage space vector. This integration is usually performed using a first-order low-pass (LP) (FOLP) filter, which counteracts the saturation and dc-drift problems associated with pure integrators. However, the dynamics of FOLP filters can be enhanced to a great extent. This paper presents a new, simple, and fast integration algorithm for VF-based control methods. Simulations and experimental tests on a VF-DPC-based system showed that the proposed algorithm leads to rapid recoveries after grid voltage sags occur. Moreover, the performance of VF-DPC under nonideal grids is discussed.

2 July 2007 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
MCMans F. Cabanas
Mans F. Cabanas
MMManuel G. Melero
Manuel G. Melero
FPFrancisco Pedrayes
Francisco Pedrayes
CGCarlos Hiram Rojas García
Carlos Hiram Rojas García
Gonzalo Arturo Alonso OrcajoGonzalo Arturo Alonso Orcajo
Gonzalo Arturo Alonso Orcajo
Fernando NuñoFernando Nuño
Fernando Nuño
Power transformers figure to be amongst the most costly pieces of equipment used in electrical systems. A major research effort has therefore focused on detecting failures of their insulating systems prior to unexpected machine outage. Although several industrial methods exist for the online and offline monitoring of power transformers, all of them are expensive and complex, and require the use of specific electronic instrumentation. For these reasons, this paper will present online analysis of transformer leakage flux as an efficient alternative procedure for assessing machine integrity and detecting the presence of insulating failures during their earliest stages. A 12-kVA 400-V/400-V power transformer was specifically manufactured for the study. A finite-element model of the machine was designed to obtain the transient distribution of leakage flux lines in the machine's transversal section under normal operating conditions and when shorted turns are intentionally produced. Very cheap and simple sensors, based on air-core coils, were built in order to measure the leakage flux of the transformer, and nondestructive tests were also applied to the machine in order to analyze pre and post failure voltages induced in the coils. Results point to the ability to detect very early stages of failure, as well as locating the position of the shorted turn in the transformer windings.

9 November 2010 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MCManés F. Cabanas
Manés F. Cabanas
FPFrancisco Pedrayes
Francisco Pedrayes
MMManuel G. Melero
Manuel G. Melero
CGCarlos Hiram Rojas García
Carlos Hiram Rojas García
José M. CanoJosé M. Cano
José M. Cano
JNJoaquin G. Norniella
Joaquin G. Norniella
Different techniques have been developed to detect rotor asymmetries in asynchronous motors. Although the reliability and the amount of information these techniques provide about a machine's state are indubitable, they still have a serious limitation: failure detection when the motor is driving a variable load torque. In this case, the motor phase currents are modulated by torque oscillations, and the information they contain about the integrity of bars and end rings is altered. This paper reports a new diagnostic method, based on the measurement of the magnetic flux linked by one stator tooth, which allows perfect simple discrimination between the actual presence of rotor asymmetries and the spurious effects caused by the oscillations in the load torque off the driven machine even when it is part of an adjustable speed drive and the motor is operating under a variable supply frequency.

28 January 2011 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
MCManés F. Cabanas
Manés F. Cabanas
FPFrancisco Pedrayes
Francisco Pedrayes
CGCarlos Hiram Rojas García
Carlos Hiram Rojas García
MMManuel G. Melero
Manuel G. Melero
JNJoaquin G. Norniella
Joaquin G. Norniella
DFDavid R. Fuentes
David R. Fuentes
The detection of rotor asymmetries in squirrel-cage induction motors has been an important research topic during the last two decades that has given rise to the development of various diagnostic techniques. Despite these techniques being reliable and providing much information about a machine's state, they still lack the capability to detect a failure when the motor is driving a machine, producing oscillations in the load torque. If this happens, then the motor phase currents are modulated by torque oscillations and the information that they contain about the integrity of the bars and endrings is no longer correct. Currently, the authors are not aware of a simple and reliable method that exists for the industrial diagnosis of rotor asymmetries in working cage motors under arbitrary load conditions. This paper describes a new diagnostic method and a new portable electronic instrument that are based on the measurement of the magnetic flux linked by one stator tooth, which allows for an optimal simple discrimination between the actual presence of rotor asymmetries and the spurious effects that are caused by the oscillations in the load torque of the driven machine.

15 April 2011 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JNJoaquin G. Norniella
Joaquin G. Norniella
José M. CanoJosé M. Cano
José M. Cano
GOGonzalo Alonso Orcajo
Gonzalo Alonso Orcajo
CGCarlos Hiram Rojas García
Carlos Hiram Rojas García
JPJoaquín Francisco Pedrayes
Joaquín Francisco Pedrayes
MMManuel G. Melero
Manuel G. Melero
One of the best known control methods for three-phase active rectifiers is the so-called direct power control (DPC). The control algorithm of the DPC is primarily based on the regulation of instantaneous active and reactive power. Because the DPC method can operate without any grid voltage sensors, instantaneous power and grid phase voltages must be estimated. The value of the essential coupling inductor between the rectifier and its three-phase supply play an important role in these estimations. This value is theoretically known; however, the grid inductance, which is sometimes difficult to determine precisely, or the coupling inductor tolerance, among other factors, may lead to errors in the inductance value. These errors have a negative and considerable effect on the instantaneous power and grid voltage estimation. Therefore, they provoke an improper operation of the DPC algorithm and the rectifier itself. To avoid these drawbacks, two simple, fast and robust inductance online estimation algorithms (analytic and iterative) are proposed in this paper. The proper operation of both methods is shown by simulation and experimental results.

1 March 2013
Verified
Conference Paper
Closed access
MCManés F. Cabanas
Manés F. Cabanas
JNJoaquin G. Norniella
Joaquin G. Norniella
MMManuel G. Melero
Manuel G. Melero
CGCarlos Hiram Rojas García
Carlos Hiram Rojas García
José M. CanoJosé M. Cano
José M. Cano
Gonzalo Arturo Alonso OrcajoGonzalo Arturo Alonso Orcajo
Gonzalo Arturo Alonso Orcajo
Insulation faults in electrical rotating machines are a matter of great industrial interest since the economic losses associated with these events are usually equal or even higher than the cost of the machine itself. For this reason, the development of monitoring and diagnostic techniques to detect this failure during its earliest stages has been a subject of great interest. On the other hand, the accuracy of the quality controls applied to the manufacturing of insulation systems is an essential issue to reduce fault rate and increase machine life. The aim of this paper is to present a comprehensive review of the scientific literature in this field, including not only research papers but also existing standards for off-line tests. A critical review of their diagnosis capability, especially on low voltage machines, is essential to clarify the reliability of these techniques as well as the convenience of its generalized industrial use.