Qing-Yuan Lu

Dr. Qing-Yuan Lu


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2023 in IEEE Microwave and Wireless Technology Letters
Verified
Journal Article
Closed access
ZXZhipeng Xia
Zhipeng Xia
JWJianpeng Wang
Jianpeng Wang
QLQing-Yuan Lu
Qing-Yuan Lu
WWWen Wu
Wen Wu
JHJiasheng Hong
Jiasheng Hong
A wideband 90 $^{\circ}$ phase shifting element for application in the quadrature phase filtering power divider (QFPD) is presented in this letter. Instead of the complex calculation procedure of phase information between reference and main branch in traditional phase shifter design, this letter initially reveals the inherent property of 90 $^{\circ}$ phase difference between terminal open-and short-circuited transmission lines (TLs) by investigating their respective electric field distributions. Following this concept and conventional filtering design method, a new topology of QFPD is constructed. For demonstration, a design example of wideband QFPD is implemented and measured. Results show that the proposed wideband QFPD exhibits phase bandwidths of 69.24%, impedance bandwidths of 58.68%, and magnitude imbalances of less than 0.7 dB, together with better than 20 dB isolation performances.

30 November 2023 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
QLQing-Yuan Lu
Qing-Yuan Lu
JWJianpeng Wang
Jianpeng Wang
LZLei Zhu
Lei Zhu
ZXZhipeng Xia
Zhipeng Xia
WWWen Wu
Wen Wu
This article presents a concise two-port asymmetric reciprocal filtering network, which mainly consists of short-and open-ended coupled lines for designing reflectionless bandpass filters (RBPFs). The network form is evolved from the lumped-element circuit to the distributed-element one. According to our theoretical analysis, it can be found that the network has the same transmission coefficients, i.e., $S_{\mathbf{12}}$ $=$ $S_{\mathbf{21}}$ . However, the reflection coefficients at the two ports are opposite. In other words, the magnitudes of $S_{\mathbf{11}}$ and $S_{\mathbf{22}}$ are the same ( $\vert S_{\mathbf{11}}$ $\vert$ $=$ $\vert S_{\mathbf{22}}\vert)$ while their phase difference is 180 $^{\circ}$ . Remarkably, this special 180 $^{\circ}$ relationship is frequency-independent. By resorting to this property, an asymmetric reciprocal filtering network can be developed by incorporating the filtering sections into the coupled lines. As a result, balanced-circuit-based RBPFs have been constructed without adding an extra phase shifter by arranging two filtering networks in a rotationally symmetrical manner. Benefiting from the frequency-independent antiphase reflection, the reflection signals of the two paths are canceled out in the stopband of the RBPF and absorbed by the isolation resistor of the employed power dividers (PDs). For demonstration, second-and fourth-order RBPFs using interdigital line resonators and split-ring resonators are, respectively, designed. Good agreements between the measured and simulated results can be observed.

16 May 2025 in BMC Nursing
Verified
Journal Article
Open access
PDF file
QHQi Fan He
Qi Fan He
JCJing Yan Cai
Jing Yan Cai
MCMin Cheng
Min Cheng
SFSu Juan Feng
Su Juan Feng
QLQing-Yuan Lu
Qing-Yuan Lu
FWFang Wang
Fang Wang
To explore the global prevalence of varicose veins among healthcare workers and their associated risk factors. Varicose veins are a common occupational disease among healthcare staff. To enhance the occupational health of this population, it is necessary to understand their prevalence and risk factors. We searched databases including Embase, PubMed, Web of Science, and CINAHL. We used random-effects meta-analyses to estimate the pooled prevalence of varicose veins and associated risk factors (odds ratios) and conducted a narrative synthesis. A meta-analysis comprising 9 studies revealed that the global prevalence of varicose veins among healthcare workers is 25% (95% CI, 18–31%). Subgroup analyses indicated that the highest prevalence, at 28% (95% CI, 9–47%), was in Middle East and North Africa. Compared with other methods, detection methods that include Doppler ultrasound examination and physical examination using the CEAP classification, along with questionnaire surveys, have both reported a higher prevalence rate of 28%. Additionally, the prevalence in developing countries, at 29% (95% CI, 19–38%), exceeds that in developed countries. The identified risk factor associated with the development of varicose veins among healthcare workers include female (OR = 3.29, 95%CI, 1.77–6.13), family history (OR = 1.86, 95%CI, 1.53–2.58) and being parous (OR = 1.75, 95%CI, 1.21–2.53). Healthcare workers have a high prevalence of varicose veins, and hospital managers can take proactive measures against the identified risk factors to reduce the risk of disease and ensure the safety of medical care. Not applicable.

1 December 2020 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
QLQing-Yuan Lu
Qing-Yuan Lu
YZYu-Jing Zhang
Yu-Jing Zhang
JCJing Cai
Jing Cai
WQWei Qin
Wei Qin
JCJian-Xin Chen
Jian-Xin Chen
A microstrip tunable diplexer with two separatelydesignable channels and multiple transmission zeroes (TZs) using common element-loaded uniform impedance resonator (UIR) is proposed. The common UIR operating in third harmonic (f3) and fifth harmonic (f5) is used for designing the two diplexer channels. The stub is loaded at the voltage-null point of f3 on the common UIR and the varactor is loaded at the open end of the stub. The varactor-loaded stub can separately tune f5 but has no effect on f3 so that the two channels can be separately designed. Meanwhile, the input port is tap-connected to the common UIR, which necessarily produces a common TZ between f3 and f5, existing in both channel filtering responses. In the tunable high channel design (at f5), the major design concept relies on choosing the properly values of three varactor diodes, the desired external quality factor and coupling coefficient can be easily obtained for realizing the constant absolute bandwidth (ABW). By properly choosing coupling schemes of the two channels, more TZs are realized at the desired locations. For demonstration, a diplexer with a fixed low channel and a tunable high channel with the constant ABW is designed, fabricated and measured.

16 April 2019 in IET Microwaves, Antennas & Propagation
Verified
Journal Article
Closed access
STShi‐Chang Tang
Shi‐Chang Tang
XWXue‐Ying Wang
Xue‐Ying Wang
QLQing-Yuan Lu
Qing-Yuan Lu
JCJian-Xin Chen
Jian-Xin Chen
Here, a fully substrate‐integrated dense dielectric patch (DDP) antenna and array is proposed. The DDP resonator based on high‐permittivity substrate on the top layer is reasonably constructed and implemented by making full use of the printed circuit board (PCB) technology, whose characteristics are theoretically analysed in detail. Accordingly, the DDP antenna element operating at the dominate TM 101 mode (cavity mode) is designed, which is fed by the substrate‐integrated strip line (SISL) through a feeding slot. The slot resonant frequency is close to the TM 101 mode of the DDP so that the antenna impedance bandwidth (BW) is extended. For further demonstration, a 1 × 4 array based on the DDP antenna element is designed and fabricated. The simulated and measured results are given, showing good agreement. The impedance BW for | S 11 | < −10 dB is about 8.4% and the peak gain reaches 11.77 dBi.

28 November 2023 in IEEE Microwave and Wireless Technology Letters
Verified
Journal Article
Closed access
ZXZhipeng Xia
Zhipeng Xia
JWJianpeng Wang
Jianpeng Wang
QLQing-Yuan Lu
Qing-Yuan Lu
WWWen Wu
Wen Wu
JHJiasheng Hong
Jiasheng Hong
This letter presents a new development of an unbalanced-to-balanced filtering power divider (FPD) with sequential rotation phase states of 0 $^{\circ}$ , 90 $^{\circ}$ , 180 $^{\circ}$ , and 270 $^{\circ}$ at four output ports. To satisfy the phase requirement at output ports, a fresh insight of 90 $^{\circ}$ phase-shifting characteristic is brought from the perspective of electric field distributions on the open-and short-circuited transmission line (TL) models. Building upon this phase-shifting concept, an unbalanced-to-balanced FPD for application in sequential rotation feeding network is presented, which obviously distinguishes from the conventional method of cascading multiple discrete devices. To verify the proposed concept, a design example is excogitated and measured. The results show that the aforementioned phase states with equal amplitude are successfully achieved at four output ports. Meanwhile, the developed FPD also exhibits phase bandwidth of 37% and impedance bandwidth of 8.5%, regarding the criterion of better than 15-dB return loss.