Effect of partial hybridization and probe positioning on the performance of a label free biosensor has been investigated in this article. Dielectric modulated dual-metal double-gate oxide stacked junctionless MOSFET based biosensor device has been considered as reference during analysis. Primarily, optimized device dimension has been proposed based on device parameters, cavity position, etc. Later, Sensitivity parameter variations in terms of threshold voltage (VTH) and drain current (IDS) have been investigated by considering partial hybridization (PH) and arrangement of receptor-biotarget pairs. Analytical modeling has been detailed to study the performance of the sensor. Extensive simulations using the SILVACO ATLAS has been done to investigate the effects. Mainly, irregular arrangement of biomolecules like enzyme (Staphylococcal nuclease) and DNA (negatively-charged) are examined here. Also minimum detection limit of the biosensor has been addressed including a capacitive model. It has been observed that the optimized cavity with dimension (400 nm 10 nm) can accommodate almost 1.016 105 (~ 17 aM) number of Myoglobin enzyme. Analysis of these practical issues during the label free detection of charged/neutral biomolecules with higher sensitivity would be efficacious to find out the promising alternative in biosensing applications.
26 October 2020 in IEEE Transactions on Nanotechnology
A dielectric modulated (DM) dual-sided dopingless (DL) GaAs 0.5 Sb 0.5 /In 0.53 Ga 0.47 As hetero-junction (HJ) Tunnel FET (DM-DDL-HTFET) based label-free biosensor architecture having hetero-gate-dielectric (HGD) has been offered. Here, virtual pocket of N + -category with differing electronic concentration (N e ) has been realized through the adjustment of source-sided-channel length (L SC ) below the gate region. Primarily, the optimized structure has been investigated considering energy-band gap, mole fraction of HJ material and gate-to-source spacer thickness (L gap,S ). Next, the efficiency of optimized DDL-HTFET model excluding nano-gap has been juxtaposed with the Si-based TFET contenders. The effect on N e , surface potential (ψ), drain-current (I DS ), and their equivalent sensitivity have been analyzed by the ATLAS device simulator considering the steric hindrance issues. 37.54% and 54% improvement in threshold voltage sensitivity can be obtained for DM-DDL-HTFET over single side DL-SiTFET (DM-SDL-SiTFET) due to variation of oxide layer thickness (T ox ) and source-side dielectric material respectively. Moreover, DM-DDL-HTFET offers 58.64% (42.18%) and 44.44% (73.33%) inferior minimum noise figure and noise conductance over DM-SDL-SiTFET at 50 (250) GHz frequency correspondingly after immobilization of APTES biomolecules.
7 February 2022 in IEEE Transactions on Nanotechnology
Sensitivity analysis of label free Bio-TFET considering repulsive steric effects (RSEs) has been addressed in the paper. Doping-less underlap dielectric modulating tunnel field effect transistor (DU-DM-TFET) is assumed like a reference structure. Initially, the efficacy of doping-less underlap (DU) TFET without cavity has been compared with the reported TFET literatures. Later, the impact on surface potential (ψ), energy band (EB), ON-current (I ON ), I ON /I OFF ratio, sub-threshold swing (SS), and their corresponding sensitivity due to variations of permittivity (k) along with charge density (N f ) of bioanalytes, length of cavity (L cavity ) and cavity thickness (T cavity ) have been addressed in this context. Non-uniform patterns of bioanalytes inside the nanogap cavity regions considering impulsive steric effects make the analysis more practical. Later, an assessment of noise features inside the cavity of DU-DM-TFET based biosensor is explored. Finally, an error assessment table is prepared to evaluate sensitivity errors (S E ) in the reported literature using the proposed RSE. A maximum 40% error in effective capacitance has been found if RSE is not considered. So, RSEs need to be considered always during the analysis of label free biosensing.
26 August 2022 in IEEE Transactions on Nanobioscience
An underlapped hetero-structure electrolyte Bio-TFET for potential of hydrogen (pH) sensing has been presented in this article. Intersection charge density (Dit) near the substrate-oxide junction can be employed to represent pH value within the simulation. A feasible fabrication scheme for the proposed model is specified here. A detailed simulation is performed with an ATLAS device simulator to examine the efficiency of the projected sensor. The impact of pH alterations on device features akin to the drain current (IDS), threshold potential (VTH), sensitivity regarding voltage (SV), and current (SI) is examined. The effect of phosphate-buffered saline (PBS) concentrations on the pH buffer are also scrutinized. Moreover, the impact of the reference voltage and current (VRef and IRef), and channel doping concentration (NCH) over SV and SI is analyzed methodically. Here, SV attains ≈ 100 mV/pH, which is superior to the Nernstian limit (59 mV/pH) and SI enhances nearly ten times per pH variation. Benchmarking is included to provide a quantitative assessment of the proposed model with the published literature. The impact of temperature on pH buffer, IDS, temporal drift parameters and sensitivities have been emphasized. Finally, the temperature-immunity aspect of the proposed Bio-HTFET based pH sensor is highlighted by comparing sensitivity parameter among state-of-the-art literature. Hence, the recommended pH sensor can be utilized as an outstanding substitute for the succeeding generation of biosensor applications.
Recognition of ovarian-cancer biomarker (HE4) in serum using dual-material In 0.53 Ga 0.47 As/Si hetero-structure charge-plasma-based extended gate TFET biosensor (DCE-HTFET) has been depicted in this paper. The virtual fabrication flow for the configuration has been mentioned here. Silvaco ATLAS TCAD device simulator is used to optimize the device for better sensitivity. The sensitivity of the proposed model in the serum biosphere for different HE4 concentrations in histological subgroups of ovarian cancer has been investigated. An optimum ON-current to OFF-current sensitivity (S ION/IOFF ) of 18.2×10 6 and sensitivity regarding sub-threshold swing (S SS ) of 95% have been achieved for the “Mucinous” type histological sub-group of ovarian-cancer biomarker having 74 pmol/L concentration. The proposed biosensor has been compared with the state-of-the-art literature to highlight its efficacy.
12 June 2023 in IEEE Transactions on Electron Devices
In this work, the impact of bioanalyte concentration and the dominant transport mechanism of biomolecules on the binding kinematics of the target biomolecules at the sensing surface have been investigated in detail. A comprehensive analysis of the fundamental parameters such as equilibrium response time and equilibrium density of the binding molecules at the sensing surface considering different concentrations of the analytes and their transport mechanisms has been performed. The impact of these realistic artifacts on the current sensitivity of emerging junctionless field effect transistors (JLFETs) and tunnel field effect transistors (TFETs)-based ion-sensitive field effect transistor (ISFET) has been investigated. Moreover, depending on the bioanalyte concentration, design guidelines for the dimensions of the sensing surface have been provided for a minimum limit of detection (LOD). The impact of charge screening and nonspecific binding on current sensitivity has also been discussed in depth. We believe that the guidelines presented in this work will enable the community to conceptualize, understand, and design novel label-free biosensors more rationally considering the practical scenario.