Manash Chanda

Manash Chanda

Auto-generated profile, based on publicly available information

Manash Chanda

Department of Electronics and Communication Engineering, Meghnad Saha Institute of Technology, Kolkata, India

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2019 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
ABAmit Bhattacharyya
Amit Bhattacharyya
MCManash Chanda
Manash Chanda
DDDebashis De
Debashis De
In this paper, a new dual-pocket (DP), dielectric modulated (DM) heterostructured tunnel field-effect transistor (DM-HTFET)-based biosensor has been reported. First, the efficacy of the DP-hetero-TFET (HTFET) has been analyzed by comparing it with other existing TFET structures. Next, a comprehensive assessment of sensitivity between single-pocket (SP) and DP-DM-HTFET biosensors for pocket thickness ( ${T}_{\text {pocket}}$ ), pocket length ( ${L}_{\text {pocket}}$ ), pocket doping ( ${N}_{\text {pocket}}$ ), work function of the gate metal, molar fraction of Ge, gate oxide layer, and gate oxide layer thickness ( ${T}_{\text {ox}}$ ) was done. Hence, a nonuniform arrangement of biomolecules inside the cavity simulation has been done using ATLAS device simulation software to validate the working ability of the proposed sensor. Significant improvement in the sensitivity due to threshold voltage (ON-current) i.e., 26.78% (78.5%), 60.8% (40.4%), 56% ( ${2.2} \times {10}^{{2}}$ %), and 40.6% (80.68%) has been observed for the DP-DM-HTFET over SP with the variation of ${T}_{\text {pocket}}$ , ${L}_{\text {pocket}}$ , ${N}_{\text {pocket}}$ , and ${T}_{\text {ox}}$ , respectively. DP-DM-HTFET-based current mirror circuit has also been demonstrated at the end. Sensitivity evaluation discloses that the DP-DM-HTFET can be a promising candidate for CMOS-based label-free biosensing applications.

1 June 2021 in IEEE Transactions on Artificial Intelligence
Verified
Journal Article
Closed access
SBShreya Bhattacharyya
Shreya Bhattacharyya
SMSouvik Majumder
Souvik Majumder
PDPapiya Debnath
Papiya Debnath
MCManash Chanda
Manash Chanda
In this paper, an automated heartbeat classification has been proposed to prevent the growing threats of cardiovascular diseases around the world. The MIT BIH Arrhythmia database has been used for the training and testing of the proposed approach. The database contains 90095 normal (N), 2781 supraventricular (SVEB), 7008 ventricular (VEB), 802 fusions (F) and 15 unclassified (Q) beats each of 30 minutes duration. Total 61 features have been extracted using the time series feature extraction library (TSFEL). Feature selection or reduction methods applied are feature scaling, removal of highly correlated and low variance features, and Random Forest Recursive Feature Elimination (RF-RFE). The methodological novelty of this study is mainly incorporation of TSFEL during feature extractions, Synthetic Minority Over-sampling Technique (SMOTE) to create a balanced dataset, an ensemble of RF and Support Vector Machine (SVM) using Weighted Majority Algorithm (WMA) for heartbeat classification to improve the results. Grid Search has been performed to optimize the hyper-parameters of RF and SVM classifiers. A final evaluation has been carried out considering a 'subject-specific scheme. The sensitivity that our approach has achieved for the arrhythmic heartbeat classes are as follows: N: 99.50%, SVEB (S): 74.20%, VEB (V): 94.22%, F: 73.21%, and Q: 0%. The corresponding positive predictive values are: N: 98.67%, SVEB (S): 90.09%, VEB (V): 95.95 %, F: 88.35%, Q: 0%. In comparison with machine learning (ML) and deep learning (DL) based state-of-the-art approaches, significant improvement in efficiency have been found.

22 September 2020 in IEEE Transactions on Nanotechnology
Verified
Journal Article
Closed access
ABAmit Bhattacharyya
Amit Bhattacharyya
MCManash Chanda
Manash Chanda
DDDebashis De
Debashis De
Effect of partial hybridization and probe positioning on the performance of a label free biosensor has been investigated in this article. Dielectric modulated dual-metal double-gate oxide stacked junctionless MOSFET based biosensor device has been considered as reference during analysis. Primarily, optimized device dimension has been proposed based on device parameters, cavity position, etc. Later, Sensitivity parameter variations in terms of threshold voltage (VTH) and drain current (IDS) have been investigated by considering partial hybridization (PH) and arrangement of receptor-biotarget pairs. Analytical modeling has been detailed to study the performance of the sensor. Extensive simulations using the SILVACO ATLAS has been done to investigate the effects. Mainly, irregular arrangement of biomolecules like enzyme (Staphylococcal nuclease) and DNA (negatively-charged) are examined here. Also minimum detection limit of the biosensor has been addressed including a capacitive model. It has been observed that the optimized cavity with dimension (400 nm 10 nm) can accommodate almost 1.016 105 (~ 17 aM) number of Myoglobin enzyme. Analysis of these practical issues during the label free detection of charged/neutral biomolecules with higher sensitivity would be efficacious to find out the promising alternative in biosensing applications.

26 October 2020 in IEEE Transactions on Nanotechnology
Verified
Journal Article
Closed access
ABAmit Bhattacharyya
Amit Bhattacharyya
MCManash Chanda
Manash Chanda
DDDebashis De
Debashis De
A dielectric modulated (DM) dual-sided dopingless (DL) GaAs 0.5 Sb 0.5 /In 0 . 53 Ga 0 . 47 As hetero-junction (HJ) Tunnel FET (DM-DDL-HTFET) based label-free biosensor architecture having hetero-gate-dielectric (HGD) has been offered. Here, virtual pocket of N + -category with differing electronic concentration (N e ) has been realized through the adjustment of source-sided-channel length (L SC ) below the gate region. Primarily, the optimized structure has been investigated considering energy-band gap, mole fraction of HJ material and gate-to-source spacer thickness (L gap,S ). Next, the efficiency of optimized DDL-HTFET model excluding nano-gap has been juxtaposed with the Si-based TFET contenders. The effect on N e , surface potential (ψ), drain-current (I DS ), and their equivalent sensitivity have been analyzed by the ATLAS device simulator considering the steric hindrance issues. 37.54% and 54% improvement in threshold voltage sensitivity can be obtained for DM-DDL-HTFET over single side DL-SiTFET (DM-SDL-SiTFET) due to variation of oxide layer thickness (T ox ) and source-side dielectric material respectively. Moreover, DM-DDL-HTFET offers 58.64% (42.18%) and 44.44% (73.33%) inferior minimum noise figure and noise conductance over DM-SDL-SiTFET at 50 (250) GHz frequency correspondingly after immobilization of APTES biomolecules.

7 February 2022 in IEEE Transactions on Nanotechnology
Verified
Journal Article
Closed access
ABAmit Bhattacharyya
Amit Bhattacharyya
DDDebashis De
Debashis De
MCManash Chanda
Manash Chanda
Sensitivity analysis of label free Bio-TFET considering repulsive steric effects (RSEs) has been addressed in the paper. Doping-less underlap dielectric modulating tunnel field effect transistor (DU-DM-TFET) is assumed like a reference structure. Initially, the efficacy of doping-less underlap (DU) TFET without cavity has been compared with the reported TFET literatures. Later, the impact on surface potential (ψ), energy band (EB), ON-current (I ON ), I ON /I OFF ratio, sub-threshold swing (SS), and their corresponding sensitivity due to variations of permittivity (k) along with charge density (N f ) of bioanalytes, length of cavity (L cavity ) and cavity thickness (T cavity ) have been addressed in this context. Non-uniform patterns of bioanalytes inside the nanogap cavity regions considering impulsive steric effects make the analysis more practical. Later, an assessment of noise features inside the cavity of DU-DM-TFET based biosensor is explored. Finally, an error assessment table is prepared to evaluate sensitivity errors (S E ) in the reported literature using the proposed RSE. A maximum 40% error in effective capacitance has been found if RSE is not considered. So, RSEs need to be considered always during the analysis of label free biosensing.

26 August 2022 in IEEE Transactions on Nanobioscience
Verified
Journal Article
Closed access
ABAmit Bhattacharyya
Amit Bhattacharyya
DDDebashis De
Debashis De
MCManash Chanda
Manash Chanda
An underlapped hetero-structure electrolyte Bio-TFET for potential of hydrogen (pH) sensing has been presented in this article. Intersection charge density (Dit) near the substrate-oxide junction can be employed to represent pH value within the simulation. A feasible fabrication scheme for the proposed model is specified here. A detailed simulation is performed with an ATLAS device simulator to examine the efficiency of the projected sensor. The impact of pH alterations on device features akin to the drain current (IDS), threshold potential (VTH), sensitivity regarding voltage (SV), and current (SI) is examined. The effect of phosphate-buffered saline (PBS) concentrations on the pH buffer are also scrutinized. Moreover, the impact of the reference voltage and current (VRef and IRef), and channel doping concentration (NCH) over SV and SI is analyzed methodically. Here, SV attains ≈ 100 mV/pH, which is superior to the Nernstian limit (59 mV/pH) and SI enhances nearly ten times per pH variation. Benchmarking is included to provide a quantitative assessment of the proposed model with the published literature. The impact of temperature on pH buffer, IDS, temporal drift parameters and sensitivities have been emphasized. Finally, the temperature-immunity aspect of the proposed Bio-HTFET based pH sensor is highlighted by comparing sensitivity parameter among state-of-the-art literature. Hence, the recommended pH sensor can be utilized as an outstanding substitute for the succeeding generation of biosensor applications.