Yintao Ma

Dr. Yintao Ma


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 July 2022 in Measurement Science and Technology
Verified
Journal Article
Closed access
YMYintao Ma
Yintao Ma
YCYao Chen
Yao Chen
Libo ZhaoLibo Zhao
Libo Zhao
MYMingzhi Yu
Mingzhi Yu
YWYanbin Wang
Yanbin Wang
ZJZhuangde Jiang
Zhuangde Jiang
A single-beam spin-exchange relaxation-free (SERF) atomic magnetometer can extract vector magnetic field information by detecting the transmission intensity of a resonant circularly polarized pumping beam, which depends sensitively on the atomic density of the alkali metal. We present a novel scheme to determine atomic density based on zero-field magnetic resonance. The resonance linewidth under different transverse DC magnetic fields is fitted by means of a quadratic function. The atomic density can be extracted from the quadratic coefficients of the fitted function. The experimental results indicate that the deviation of measured density is less than two times compared with the theoretical values between 378 K and 403 K. Furthermore, the influence of modulation field on resonance linewidth is investigated experimentally and theoretically. A miniature single-beam SERF atomic magnetometer with a sensor head volume of only 16.2 cm 3 and the measuring sensitivity of 40 fT/ Hz 1/2 has been achieved. These results should be beneficial for guiding the development of a chip-scale atomic magnetometer with high sensitivity and spatial resolution for bio-magnetic field imaging applications.

16 June 2022 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
YCYao Chen
Yao Chen
MYMingzhi Yu
Mingzhi Yu
YMYintao Ma
Yintao Ma
YWYanbin Wang
Yanbin Wang
JGJu Guo
Ju Guo
Libo ZhaoLibo Zhao
Libo Zhao
The combination of micro-machined technology with atomic spin gyroscope (ASG) devices can be used to fabricate a chip-scale atomic spin gyroscope (CASG). The core of the gyroscope is a micromachined vapour cell, which contains alkali metal and isotope-enriched noble gases, such as 129 Xe and 131 Xe . The quadrupolar frequency shift of 131 Xe is a key parameter that can affect the drift of the ASG and is related to the material of the cell in which they are contained. In micromachining technology, the utilised material is silicon. In this study, we investigated the electric quadrupolar frequency shift of 131 Xe atoms with the silicon wall of a micro-machined vapour cell. A cylindrical micromachined vapour cell was utilised in the experiment, and a large part of the inner cell surface comprised silicon material. We studied the temperature dependence of the 129 Xe spin relaxation and 131 Xe frequency shifts to evaluate the interaction of the nuclear spin with the container wall and alkali metal atoms. The results show that the average twisted angle of the 131 Xe nuclear spins as they collided with the silicon wall was measured as 29 × 10 − 6 rad. The desorption energy required for the 131 Xe nuclear spin to escape from the silicon surface was E s i = 0.009   eV . This study could help improve the bias stability of the CASG, which is a key parameter for the gyroscope, and may help to develop a method to study the surface properties of various materials.

8 January 2025 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
YMYintao Ma
Yintao Ma
YCYao Chen
Yao Chen
MYMingzhi Yu
Mingzhi Yu
YWYanbin Wang
Yanbin Wang
JGJu Guo
Ju Guo
Libo ZhaoLibo Zhao
Libo Zhao
Atomic magnetometers, a prominent class of quantum sensors, have become increasingly significant in magnetometry, with extensive applications in cutting-edge physics, biomedical imaging, industrial inspection, and beyond. However, the power consumption of an atomic magnetometer is primarily dominated by that demanded to heat the atomic vapor cell to its operating temperature. This operating temperature determines the alkali-metal atomic density, thereby influencing the magnetic field sensitivity and overall power consumption, which poses a potential obstacle to the large-scale engineering application of atomic magnetometers. In this article, a novel heating method utilizing renewable solar energy is proposed for the first time, which can surpass the limitation of conventional heating methods in thermo-atom-based quantum sensors. By exploiting an intelligent closed-loop control system to adaptively regulate the functionalized sunlight power, this proposed method has the capability of both high heating efficiency and accuracy. The heating properties and laser absorption spectrum at different temperatures up to 180 °C are characterized substantiating the feasibility of utilizing sunlight. Moreover, a sunlight-heated, highly sensitive, microfabricated atomic magnetometer with a magnetic field sensitivity of 18 fT/Hz 1/2 is demonstrated. And the single-chamber microelectromechanical system atomic vapor cell as the key component is fabricated by utilizing deep silicon micromachining and anodic bonding techniques. This proposed technique can be further extended to all quantum sensing systems based on thermal atomic ensembles and open up new possibilities for the development of self-powered, environmentally friendly quantum sensors.

16 September 2025 in ACS Omega
Verified
Journal Article
Open access
MYMingzhi Yu
Mingzhi Yu
YWYanbin Wang
Yanbin Wang
YMYintao Ma
Yintao Ma
YCYao Chen
Yao Chen
JGJu Guo
Ju Guo
Libo ZhaoLibo Zhao
Libo Zhao
Research on the electric quadrupole frequency shift mechanism and nuclear spin relaxation of 129Xe-131Xe in alkali metal atomic vapor cells fabricated using microelectromechanical systems (MEMS) technology remains in its early stages. Therefore, an in-depth investigation in this field is crucial for enhancing the performance of miniaturized atomic gyroscopes and other quantum devices. This study provides a comprehensive analysis of the electric quadrupole frequency shift and relaxation of 129Xe-131Xe nuclear spins in a stemless cubic MEMS vapor cell. To elucidate the microscopic characteristics of wall interactions, nuclear spin quadrupole interactions with mixed silicon and glass surfaces in MEMS vapor cells were examined. The influence of the angle between the vapor cell's geometric axis and the applied magnetic field on the electric quadrupole frequency shift was investigated, leading to the determination of the vapor cell's asymmetry parameter η and the average twist angle ⟨θ⟩ of nuclear spin-wall collisions. Furthermore, the temperature dependence of the electric quadrupole frequency shift in 131Xe atoms was characterized, enabling the extraction of the desorption activation energy (E A ) of 131Xe on the MEMS vapor cell surface. By analyzing the free induction decay (FID) signals of 129Xe and 131Xe at varying temperatures, the relationship between their relaxation rates and temperature was established. These findings offer valuable insights for optimizing nuclear spin relaxation times in microatomic gyroscopes.

12 November 2026 in Applied Physics Reviews
Verified
Journal Article
Closed access
YMYintao Ma
Yintao Ma
DXDi Xiao
Di Xiao
PCPan Chen
Pan Chen
JGJu Guo
Ju Guo
YCYao Chen
Yao Chen
LZLibo Zhao
Libo Zhao
Alkali-vapor atom-based quantum sensors are urgently needed in the cutting-edge frontier of extremely weak field measurements. However, the generation and control of atomic vapor currently heavily rely on the flexible heater and the discrete temperature sensor, which severely hinder practical application. Herein, we report on-chip, high-performance temperature-control chips with very low residual magnetic flux density, enabled by the multipole-field suppression microstructure designed by particle swarm optimization algorithms, achieving two to three orders of magnitude reduction compared with conventional structures. The unique structure is formed by multiturn parallel winding arrangement, resulting in a synergistic cancelation of the stray magnetic field. A one-step manufacturing process based on oxygen plasma treatment and metal lift-off facilitated tough adhesion is developed for high-efficiency fabrication. As a result, a low magnetic field coefficient of ∼4.3 pT/mA, a high heating power of ∼1 W, and an exceptional temperature fluctuation of ±10 mK are reached, which represents significant improvement in comprehensive performance compared to previous reports. Furthermore, we configure a chip-scale quantum magnetometer with the optimal sensitivity of 10 fT/Hz1/2. Benefiting from its high-performance capabilities, integrated functionality, and the straightforward microfabrication process, the methods reported here are, in principle, generalizable to all thermal alkali-atom-based quantum sensors, including atomic magnetometers, atomic clocks, atomic gyroscopes, and beyond.

5 June 2026 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
JGJu Guo
Ju Guo
YMYintao Ma
Yintao Ma
DLDejiang Lu
Dejiang Lu
MYMingzhi Yu
Mingzhi Yu
YWYanbin Wang
Yanbin Wang
YCYao Chen
Yao Chen
Accurate measurement of strong magnetic fields in the Tesla range remains a persistent challenge due to calibration drift, nonlinearity, and spatial gradient sensitivity. Here, we present a compact magnetometry approach based on sideband-overlap Zeeman spectroscopy, enabled by a functionalized MEMS cesium vapor cell. The vapor cell features a dual-chamber glass–Si–glass structure with integrated microheaters on the optical window. A first-order electro-optic modulator produces optical sidebands aligned with the σ+ and \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} $${{\rm{\sigma }}}^{-}$$σ− Zeeman-split components of the Cs D1 line under the hyperfine Paschen–Back regime. Magnetic field scanning from zero to Tesla-scale fields enables extraction of the frequency offset between reference and Zeeman-shifted spectra. This frequency shift is directly converted into magnetic field strength using Zeeman spectroscopy in the hyperfine Paschen–Back regime. The method resolves sixteen Zeeman transitions (eight \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} $${{\rm{\sigma }}}^{+}$$σ+ and eight \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} $${{\rm{\sigma }}}^{-}$$σ−), allowing measurement of a field strength of 0.6694921 T, with a single-shot resolution of 6.4 μT and a cross-transition repeatability of σB = 8.9 μT (corresponding to 13 ppm at 0.6695 T). In a millimeter-scale sensing volume, the system achieves sub-10 μT repeatability without requiring a uniform bias field. These results indicate that the microfabricated high-field magnetometer can serve as a compact and practical approach for Tesla-range field measurement and pave the way for chip-scale quantum devices.