Metal-organic frameworks (MOFs) with their exceptional properties have the potential to revolutionize the field of electrochemistry and pave the way for new and exciting applications. MOFs is an excellent choice as an active electrocatalyst component in the fabrication of electrochemical sensors. Here, bimetallic NiCo-MOFs, monometallic Ni-MOFs, and Co-MOFs were fabricated to modify the carbon paste electrode. Moreover, the ratio between Co and Ni within the bimetallic MOFs was optimized. Our aim in this work is to synthesize different compositions from bimetallic MOFs and systematically compare their catalytic activity with mono-metallic MOFs on paracetamol. The structure and properties of the 2D NiCo-MOFs were characterized by scanning electron microscope, X-ray photoelectron spectroscopy, Fourier transform infrared, and electrochemical method. Bimetallic Ni0.75Co0.25-MOFs modified carbon paste sensor displayed the optimum sensing performance for the electrochemical detection of paracetamol. A linear response over the range 6.00 × 10− 7 to 1.00 × 10− 4 M with a detection limit of 2.10 × 10− 8 M was obtained. The proposed method was applied to detect paracetamol in spiked human plasma and to determine paracetamol in the presence of its major toxic impurity, p-aminophenol. These findings suggest the considerable potential use of the newly developed sensor as a point-of-care tool for detecting paracetamol and p-aminophenol in the future.
A novel bi-ligand nickel-based metal–organic framework (Ni-BTC-PYDC MOF) was synthesized using benzene tricarboxylic acid (BTC) and pyridine-2,3-dicarboxylic acid (PYDC) as ligands. This MOF showed improved surface area, structural stability, and electron transfer compared to mono-ligand Ni-MOFs. Characterization by SEM, EDX, EDS mapping, XRD, and FT-IR confirmed its enhanced morphology and nickel content. The catalyst rapidly reduced methyl orange (MO) dye in water, achieving rapid and significant decolorization within 90 s using sodium borohydride (NaBH₄) under mild conditions. It maintained high activity over ten reuse cycles with minimal loss, performing best at pH 5 due to efficient hydride generation and proton-assisted electron transfer. These findings demonstrate that the bi-ligand Ni-MOF is a promising, stable, and reusable catalyst for removing toxic azo dyes from wastewater.
1 September 2021 in Current Pharmaceutical Analysis
Background: PARTIAL Least Squares (PLS) and Principal Component Regression (PCR) are two well-known chemometric methods based on dimension reduction techniques. They can be very practical analyzing a large data set of multiple correlated predictor variables. Objective: In the presented work, the resolving power of spectrophotometric assisted mathematical techniques was implemented for the simultaneous determination of two active ingredients; ephedrine hydrochloride (EPH) and naphazoline nitrate (NAPH), in a matrix of excipients. Methods: To build the PLS and PCR models, a calibration set was prepared where the two drugs, in combination with the interfering parabens, were modeled by multilevel multifactor design. The proposed models successfully predicted the concentrations of both drugs in validation samples with low Root Mean Squared Error of Prediction (RMSEP). Results: The results revealed the ability of the mentioned multivariate calibration models to analyze EPH and NAPH in the presence of the interfering parabens with high selectivity in the concentration ranges of 4.00-20.00 μg mL-1 and 1.00-9.00 μg mL-1, respectively. Conclusion: A commercially available nasal spray was successfully analyzed using the developed methods without interfering with other dosage form additives.
2 February 2026 in Journal of Analytical Science and Technology
The development of inorganic nanomaterial-based enzyme mimics has emerged as a promising strategy to overcome the high cost and limited stability of natural enzymes. Metal–organic frameworks (MOFs) are particularly appealing for biomimetic catalysis due to their high surface area, adjustable composition, and accessible functional sites. In this study, we present a point-of-care (POC) colorimetric biosensor that employs two-dimensional cobalt-based MOFs (2D Co-MOFs) as peroxidase-like catalysts for the detection of glucose and hydrogen peroxide (H₂O₂). The use of a 2D MOF structure provides improved exposure of active sites compared to bulk MOFs, contributing to reliable and efficient catalytic performance. The sensor demonstrates a linear detection range for H₂O₂ from 5.0 μM to 200.0 μM with a detection limit of 4.60 μM, and enables glucose detection within a linear range of 27.8 μM to 666.0 μM. The nanozyme was characterized using SEM,XRD and FTIR spectroscopy. The suggested platform is ideal for point-of-care application due to its sensitivity, low detection limits, and simple operation. The results demonstrate that 2D Co-MOF nanosheets can function as efficient enzyme mimics for biomolecule detection and could potentially help in the advancement of practical diagnostic sensor development.
Determination of pharmaceuticals in biological matrices is crucial for pharmaceutical development, toxicological studies, and therapeutic drug monitoring. Accurate quantification of drugs in plasma requires reliable analytical techniques; however, the complexity of biological fluids hinders direct analysis without an effective sample preparation step. In this study, Fe₃O₄ was synthesized using mussel-inspired magnetic molecularly imprinted polymer nanoparticles (MIP NPs) through a single-step auto-polymerization process with levofloxacin as the template and methyldopa as the monomer. The integration of Fe₃O₄ core synthesis, self-polymerization, and molecular imprinting in a single step provides a unique and streamlined methodology, reducing fabrication complexity and time. The prepared Fe₃O₄@MIP NPs were successfully applied to extract levofloxacin from spiked human plasma. UV–spectroscopy studies confirmed selective recognition, binding efficiency, and optimization of recovery conditions, achieving approximately 93.5% recovery. The Fe₃O₄@MIP NPs demonstrated significant imprinting capability and high adsorption capacity. This approach offers a novel and cost-effective platform for rapid, selective drug extraction from complex biological matrices, with direct clinical relevance for therapeutic drug monitoring of levofloxacin in multidrug-resistant tuberculosis, particularly suited for resource-limited settings.
A carbon paste electrode (CPE) based on a g-C 3 N 4 @nZVI/CNT nanocomposite was fabricated via chemical reduction and subsequently evaluated towards electrochemical detection of uric acid (UA) via differential pulse voltammetry (DPV). During synthesis, graphitic carbon nitride (g-C 3 N 4 ) serves as a durable substrate with extensive surface area promoting the homogeneous distribution of nano zero-valent iron (nZVI) particles. Carbon nanotubes (CNTs) were incorporated into the composite to enhance electrical conductivity and mechanical stability. The subsequent nanocomposite was characterized by scanning electron microscopy and energy-dispersive X-ray spectroscopy, confirming the successful integration of g-C 3 N 4 , nZVI, and CNTs with well-dispersed iron nanoparticles on the g-C 3 N 4 matrix. The resulting g-C 3 N 4 @nZVI/CNT-modified CPE demonstrated superior electrochemical sensitivity toward UA as evidenced by a pronounced increase in peak current during DPV analysis compared to bare and individually modified electrodes. Under optimized conditions, the sensor exhibited a linear response of 2.0–100.0 μM and detection limit of 1.7 μM. The electrode maintained high selectivity in the presence of common interferants with good repeatability and long-term operational stability. These findings highlight the synergistic interaction among g-C 3 N 4 , nZVI, and CNTs in boosting electron transfer and catalytic activity, making this composite a promising, cost-effective, and scalable solution for sensitive UA detection in clinical diagnostics and environmental monitoring.