The objectives of this study were to evaluate the shear bond strength (SBS) of a resin composite (RC) and a resin-modified glass ionomer (RMGI) to four different bioceramic materials and to compare the effects of the immediate vs. delayed placement of restoration on the SBS. A total of 160 Teflon blocks and 40 blocks/material, were randomly filled with one of the bioceramic materials (NeoPUTTY®, NeoMTA2®, TotalFill® BC RRM™ Fast Set Putty, and ProRoot® MTA). The restoration was performed immediately or in a delayed time frame (after 7 days) using a Filtek™ Z350 XT Flowable composite (bonded to the bioceramic materials using Single bond universal 3M) or GC Fuji II LC® RMGI. The SBS test was performed at a crosshead speed of 1 mm/min, and the failure mode was evaluated under a digital microscope by one blinded examiner. One-way analysis of variance (ANOVA) with the Games–Howell post hoc test was used to compare the mean SBS between the groups. The mean SBS of the bioceramic materials to RC was significantly higher than to RMGI except for ProRoot MTA (p-value 0.65). The SBS values to RC were as follows: ProRoot MTA (7.64 MPa); NeoMTA2 (8.57 MPa) which was significantly higher than both NeoPUTTY (4.04 MPa) and TotalFill® BC RRM™ Fast Set Putty (4.38 MPa). For RMGI groups, ProRoot MTA showed the highest SBS (7.18 MPa), followed by NeoMTA2 (4.15 MPa), NeoPUTTY (1.62 MPa), and TotalFill® BC RRM™ Fast Set Putty (1.54 MPa). The delayed timing restoration showed a significantly higher SBS than the immediate, except for the immediate RMGI restoration with MTA. To conclude, the SBS of RC to the bioceramic materials was significantly higher than RMGI, except for ProRoot MTA. Both restorative materials had a significantly higher SBS to the MTA groups in comparison to premixed bioceramics. Delayed RC restoration had a higher SBS than immediate restoration. Similarly, delayed RMGI restoration had a higher SBS than immediate restoration with premixed bioceramic but not with MTA.
The aim of the present study was to evaluate the fracture loads of polymethyl methacrylate (PMMA) complete denture bases reinforced with glass-fiber mesh and orthopedic casting tape (OCT) in comparison to conventional PMMA dentures under artificial aging. Dental fiberglass framework (Group 1) and OCT (Group 2 and 3) reinforced PMMA acrylic dentures were fabricated on the edentulous ridge. Ten PMMA dentures without reinforcement (Group 4) were included as controls. All specimens were placed in a chewing simulator chamber, and fatigue load was applied. To assess the fracture loads, static loads with a universal testing machine were applied. Fractured specimens in each group were evaluated under a scanning electron microscope. The data were statistically analyzed employing analysis of variance and Tukey post-hoc test. The association of denture weight and thickness on fracture load was assessed using Pearson and Spearman correlations. Dental fiberglass (Group 1) displayed the highest fracture load (692.33 ± 751.41 N), and Group 4 (control) exhibited the lowest fracture loads (281.41 ± 302.51 N). Dentures reinforced with fiberglass mesh framework exhibited intact fractures. In contrast, Group 2 and 3 specimens using OCT demonstrated ditching fractures. It was observed that the thickness and weight of all the reinforced specimens influenced the load required to fracture the dentures (p < 0.001). Denture specimens strengthened with OCT (Groups 2 and 3) exhibited failure loads lower than dental fiberglass (Group 1) specimens but higher than unreinforced controls.
(1) Background: An ideal bond strength between endodontic posts and root canal dentin is essential for optimal retention and good prognosis. This study aimed to evaluate the push-out bond strength (PBS) of prefabricated fiber and metal posts, luted with resin cement to natural dentin. (2) Methods: Extracted premolars with similar root dimensions were assigned into two groups of 30 each for the metal and fiber posts. Teeth were mounted in acrylic blocks exposing 2 mm of the coronal root. Teeth were subjected to endodontic treatment and post-space preparations. Two groups were further subdivided into three sub-groups (n = 10) according to the size of the posts (# 4, 5 and 6). Posts were cemented with resin cement. Specimens were sectioned into 4 mm slices and subjected to the PBS test. (3) Results: The mean PBS was similar for the metal and fiber posts bonded with resin cement, showing a statistically significant result. An increase in post size increased the bond strength initially, but a further increase in size did not show any marked difference. A total of 71.66% of tested specimens failed with the adhesive failure mode. (4) Conclusions: Metal posts showed slightly higher retention compared to the fiber posts, although the p-value was similar for both types. An increase in the size of posts showed increased retention. The most common mode of failure was adhesive failure between cement and dentin.
The surface roughness (Ra) of indirect computer-aided design/computer-aided manufacturing (CAD/CAM)-fabricated dental restorations is crucial for their long-term durability. This study intended to evaluate the Ra of five different types of contemporary indirect CAD/CAM restorative materials with varying compositions that were glazed and finished/polished. A total of 75 specimens, disc-shaped (10 mm × 2 mm), were obtained from five materials (n = 15) (Tetric CAD, IPS e.max CAD, IPS e.max ZirCAD, CELTRA Duo, and Vita Enamic) and fabricated by CAD/CAM. One of the two surfaces for each specimen was subjected to glazing, while the other surface was subjected to finishing/polishing. The Ra of the two surfaces in micrometers (μm) was evaluated using a Profilometer, while the surface topography was examined using a scanning electron microscope. Using SPSS, the Kruskal–Wallis, post hoc Conover, and Mann–Whitney tests were used to statistically evaluate the data. A comparison of the Ra for the finished/polished surfaces of the five test materials showed significant differences (p < 0.0001). Among the finished/polished surfaces, the mean rank values of Vita Enamic were significantly higher than the other four test materials (p < 0.0001). A comparison of the Ra of glazed surfaces among the five study materials revealed significant differences (p < 0.0001). The Ra for the IPS e.max ZirCAD material was significantly higher than the rest of the four materials (p < 0.001). A comparison of the Ra for two types of surface conditioning within each of the five test materials showed a significant difference (p < 0.05). Only for IPS e.max ZirCAD was the Ra of the glazed surface significantly higher than the finished/polished surface (p < 0.0001). Significant variations in the surface roughness (Ra) were exhibited between the finished/polished and glazed surfaces of the five test materials. Hybrid ceramics showed the highest Ra values for the finished/polished surfaces, and zirconia exhibited the highest Ra values among the glazed surfaces among the tested materials. The Ra values of either finished/polished or glazed surfaces of the test materials were within the clinically acceptable range (0.2–0.5 μm), except for the glazed surface of the zirconia ceramics (0.84 μm).
The study aimed at synthesizing β-tricalcium phosphate (β-TCP) nanoparticles and comparing the mechanical properties and dentin interaction of two adhesives: experimental adhesive (EA) and EA with 5 wt.% β-TCP nanoparticles (β-TCP-5%). These filler nanoparticles were synthesized and then characterized with scanning electron microscopy (SEM) and micro-Raman spectroscopy. The β-TCP nanoparticles were incorporated in the adhesives to form two groups: gp-1: EA (control) and gp-2: β-TCP-5%. These adhesives were characterized by SEM, energy-dispersive X-ray (EDX) spectroscopy and were also assessed for their micro-tensile bond strength (μTBS) with (TC) and without thermocycling (NTC). Fourier Transform Infrared (FTIR) spectroscopy was performed to evaluate the degree of conversion (DC) of two adhesives. The β-TCP filler was seen as irregularly shaped agglomerates on SEM. The micro-Raman spectra revealed characteristic peaks associated with β-TCP nanoparticles. Both adhesives presented suitable dentin interaction, which was demonstrated by the formation of resin tags of variable depths. The EDX analysis verified the existence of calcium (Ca) and phosphate (P) for the β-TCP-5% group. The greatest μTBS values were shown by β-TCP-5% group samples when they were non-thermocycled (NTC) (β-TCP-5%-NTC: 34.11 ± 3.46) followed by the thermocycled (TC) samples of the same group (β-TCP-5%-TC: 30.38 ± 3.66), compared with the EA group. Although the DC presented by β-TCP-5% group was comparable to the EA group, it was still lower. The addition of β-TCP nanoparticles in the adhesive improved its μTBS and resulted in a suitable dentin interaction, seen in the form of hybrid layer and resin tag formation. Nonetheless, a decreased DC was observed for the β-TCP-5% adhesive. Future studies probing the effect of different filler concentrations on various properties of the adhesive are warranted.
1 December 2021 in Photodiagnosis and Photodynamic Therapy