New emission legislation requires number concentration measurements of particles emitted by passenger cars during the periodic technical inspection (PTI). For that, suitable instruments are needed, e.g., to detect failures of diesel particulate filters. Diffusion charging is well established as a charging method for particle sensors and is suited to realize low-cost instruments for exhaust particle number measurements in the appropriate size and concentration regime. In order to manufacture affordable instruments, not only the sensor must be low in cost, but also the calibration procedure must be simple and reliable. We experimentally investigated the impact of test aerosol properties - such as material, size, concentration and morphology - on the counting efficiency of two pulsed-mode, unipolar diffusion charging approaches: (i) conventional diffusion charging and (ii) modulated precipitation. By separately characterizing the particle charging process and the overall sensor response with different test aerosols, we found that the modulated precipitation principle shows a very good correlation to particle number concentration, although the method significantly depends on the particle morphology. The conventional approach is not well suited for particle number measurements due to its intrinsic dependency on particle size. We demonstrate that the counting efficiency of the modulated precipitation configuration measured with different tests aerosols stays within 3% for particle sizes up to 80 nm. The difference between a calibration with soot and salt particles with respect to the total solid particle number concentration was estimated to be smaller than 11%. Thus, a calibration according to recently introduced PTI legislation with any of the test aerosols considered is feasible. Tailpipe measurements confirmed the applicability of the modulated precipitation configuration for PTI. As a consequence, the use of diffusion charging based instruments in periodic inspections seams to be suitable due to appropriate sensor response and the simplicity of the calibration process.
Diffusion Charging followed by particle capture and measurement is a promising method for determining particle number concentration of automotive exhaust. In addition, the method allows for the determination of a mean particle size, which is of high relevance with respect to health impacts. We investigate three different measurement configurations based on unipolar diffusion charging and electrostatic particle capture, using an analytical non-dimensional model, as well as a transient, multi-physical three-dimensional model. The comprehensive modelling techniques enable prediction of the transient electrical current signals induced by the motion of charged aerosols. Comparison of the multi-physical modelling approach to analytical calculations and experimental data demonstrate model validation. The understanding gained from the modelling techniques enables a study of sensor design and calibration. Particle number concentration sensing is demonstrated for both a modulated precipitation configuration and a two-stage measurement configuration. With the latter, additional information on the mean particle size is extracted.
Fine mode particulate matter (PM) is known to be a major risk for human health as it can cause respiratory and cardiovascular diseases. Whether produced from anthropogenic or natural processes, fine mode PM is often electrically charged with positive, negative and/or bipolar charges. These preexisting charges can, in some cases, significantly affect measurements from sensors which involve a charging stage prior to measurement by, e.g., electrometry. In this work, we demonstrate quantitatively the impact of preexisting charges ( ) on three different unipolar diffusion charging (DC) configurations using both simulations and experiments. The DC configurations include traditional steady state (SS) DC and pulsed modes of DC, where in all configurations a positive corona charger is used. We show that the impact of preexisting charges on SS and modulated precipitation (MP) DC is comparable. Positively pre-charged particles cause a larger deviation for SS and MP DC, in contrast to modulated diffusion charging (MDC), where negatively pre-charged particles have a greater impact. In addition, we show that the ion concentration in the charging region can be increased to significantly reduce the resulting error caused by the pre-charges for both SS DC and MP DC, in contrast to MDC. These results show that the influence of unipolarly pre-charged particles is very differently pronounced for the different modes of DC. The impact strongly depends on the polarity of the pre-charges, characteristics of the charger and the DC configuration itself. These insights are particularly interesting for the design and the application of DC based sensors.
18 February 2023 in Aerosol Science and Technology
In 2011, the Euro 5b light-duty vehicle legislation introduced particle number (PN) limits for vehicle homologation. To measure PN concentrations, specific condensation particle counters (CPC) with a counting efficiency (CE) of 50% at 23 nm are required. The usage of such automotive CPCs will significantly increase with the upcoming legislation for PN measurements during periodic technical inspections, which comes along with the need for simple calibration methods for particle number counters using salt particles. In this work, we examined the counting characteristics of an automotive AVL 23 nm CPC with inorganic salt particles. We further investigated the usability of different atomized inorganic salt particles for calibration purposes focusing on CE and linearity. The CE varies greatly depending on the chemical salt composition: While NaI was fully activated down to 18 nm and linear over the full concentration range, the CE of other atomized salt solutions showed a strong concentration dependency with a d50 diameter ranging from 38.2 nm to 69.5 nm for atomized NaCl with increasing concentration. Such effects were not found for tube-furnace generated salt particles within similar concentration ranges. When a hot dilution was applied, the non-linear behavior was minimized and the CE overall increased, leading to a d50 of 27.3 nm for atomized NaCl. Based on those findings, we propose a simplified calibration method for automotive PN counters without the need for a differential mobility analyzer due to the high CE of atomized NaI particles.