Martin Kupper

Dr. Martin Kupper

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2023 in Aerosol Science and Technology
Verified
Journal Article
Open access
HKH. Krasa
H. Krasa
MKMartin Kupper
Martin Kupper
MSMario Schriefl
Mario Schriefl
ABAlexander Bergmann
Alexander Bergmann
In 2011, the Euro 5b light-duty vehicle legislation introduced particle number (PN) limits for vehicle homologation. To measure PN concentrations, specific condensation particle counters (CPC) with a counting efficiency (CE) of 50% at 23 nm are required. The usage of such automotive CPCs will significantly increase with the upcoming legislation for PN measurements during periodic technical inspections, which comes along with the need for simple calibration methods for particle number counters using salt particles. In this work, we examined the counting characteristics of an automotive AVL 23 nm CPC with inorganic salt particles. We further investigated the usability of different atomized inorganic salt particles for calibration purposes focusing on CE and linearity. The CE varies greatly depending on the chemical salt composition: While NaI was fully activated down to 18 nm and linear over the full concentration range, the CE of other atomized salt solutions showed a strong concentration dependency with a d50 diameter ranging from 38.2 nm to 69.5 nm for atomized NaCl with increasing concentration. Such effects were not found for tube-furnace generated salt particles within similar concentration ranges. When a hot dilution was applied, the non-linear behavior was minimized and the CE overall increased, leading to a d50 of 27.3 nm for atomized NaCl. Based on those findings, we propose a simplified calibration method for automotive PN counters without the need for a differential mobility analyzer due to the high CE of atomized NaI particles.

29 March 2024 in Atmosphere
Verified
Journal Article
Open access
PDF file
MKMartin Kupper
Martin Kupper
Ludwig SchubertLudwig Schubert
Ludwig Schubert
MNManfred Nachtnebel
Manfred Nachtnebel
HSHartmuth Schröttner
Hartmuth Schröttner
MHMichael Peter Huber
Michael Peter Huber
ABAlexander Bergmann
Alexander Bergmann
A current challenge in realising clean road transport is non-exhaust emissions. Important advances regarding measurement systems, including well-defined characterisation techniques, as well as regulation, will be made in the next few years. In this work, we present the detailed results of particle emission analyses, consisting of aerosol (size distribution, particle number (PN), and mass (PM)) and electron microscopy (EM) measurements, under different load conditions on a test bed for a wheel suspension and brakes. Standard tyres and brakes from serial production were tested with a high-load driving cycle, while particle measurements were conducted by gravimetric measurements and with a TSI SMPS, a TSI APS, and a GRIMM OPS. Furthermore, samples were analysed by electron microscopy. A bimodal particle size distribution (PSD) was obtained with an SMPS, with peaks at 20 nm and around 400 nm. The results of an EM analysis of >1400 single particles from the electrostatic sampler match the PSD results. The EM analysis also showed ultrafine particles, mainly containing O, Fe, Si, Ba, Mg, and S, and also fractal particles with high-C fractions. Our results suggest, in agreement with the previously published literature, that particulate emissions are related to the brake disc temperature and occur in significant amounts above a threshold temperature.

23 August 2024 in Atmosphere
Verified
Journal Article
Open access
PDF file
HIHafiz Hashim Imtiaz
Hafiz Hashim Imtiaz
PSPaul Schaffer
Paul Schaffer
YLYingjie Liu
Yingjie Liu
PHPaul Hesse
Paul Hesse
ABAlexander Bergmann
Alexander Bergmann
MKMartin Kupper
Martin Kupper
Remote emission sensing (RES) is a state-of-the-art technique for monitoring thousands of vehicles on the road every day to detect high emitters. Modern commercial RES systems use absorption spectroscopy to measure the ratio of pollutants to CO2 from vehicle exhaust gases. In this work, we present an approach to enable direct concentration measurements by spectroscopic techniques in RES through measurement of the absorption path length. Our gas schlieren imaging sensor (GSIS) system operates on the principle of background-oriented schlieren (BOS) imaging in combination with advanced image processing and deep learning techniques to calculate detected exhaust plume sizes. We performed a qualitative as well as a quantitative analysis of vehicle exhaust and plume dimensions with the GSIS system. We present the system details and results from the GSIS system in the lab in comparison to a BOS model based on flow simulations, the results from characterization measurements in the lab with defined gas mixtures and temperatures, and the results from measurements on the road from different vehicles.

3 January 2020 in Aerosol Science and Technology
Verified
Journal Article
Closed access
MKMartin Kupper
Martin Kupper
MKMartin Kraft
Martin Kraft
ABAdam Boies
Adam Boies
ABAlexander Bergmann
Alexander Bergmann
A stable high-temperature condensation particle counter (HTCPC), operating above 170 °C was realized. First a dedicated working fluid was identified in a two-stage process, consisting of a pre-selection based on relevant substance properties and a subsequent experimental evaluation. A prototype for experimental evaluation of the concept was designed and built, supported by CFD simulations considering the properties of the working fluid. The surface tension of the working fluid was measured at different temperatures, revealing higher values than predicted and a specific adhesion to graphite. With a especially developed high-temperature optics module, the proof of principle was verified. Calibration measurements have been performed against an automotive grade CPC. The operation in compliance to the legislative requirements for particle number counters was successfully proven.

16 July 2021 in Plasma
Verified
Journal Article
Open access
PDF file
HKHelmut Krasa
Helmut Krasa
MSMario Schriefl
Mario Schriefl
MKMartin Kupper
Martin Kupper
AMAlexander Melischnig
Alexander Melischnig
ABAlexander Bergmann
Alexander Bergmann
A novel piezoelectric plasma generator developed by TDK Electronics GmbH & Co. OG, the CeraPlas®, was investigated for its feasibility as a charger for aerosol particles. The CeraPlas® charger was directly compared to a commercially available bipolar X-ray charger regarding its efficiency of charging atomized NaCl particles in a size range from 30 nm to 100 nm. First results show the ability of the CeraPlas® to perform bipolar aerosol charging with high reproducibility, and measurements of the charge distribution in the Nit product yielded about 1012 m−3 s for our experimental charging configuration. Unwanted generation of ozone was suppressed by a dedicated charging chamber and operation in N2 atmosphere.

19 February 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
MKMartin Kupper
Martin Kupper
Ludwig SchubertLudwig Schubert
Ludwig Schubert
MNManfred Nachtnebel
Manfred Nachtnebel
HSHartmuth Schröttner
Hartmuth Schröttner
MHMichael Peter Huber
Michael Peter Huber
ABAlexander Bergmann
Alexander Bergmann
The up-to-date challenge towards clean road transport are non-exhaust emissions. Important advances regarding measurement systems, including well defined characterisation techniques, as well as regulation, will happen in the next few years. In this work we present detailed results of particle emissions from a test bed for wheel suspension and brakes, consisting of aerosol (size distribution, particle number (PN) and mass (PM)) and electron microscopy measurements (EM) under different load conditions. Standard tyres and brakes from series production were tested with a high-load driving cycle while particle measurements were conducted by gravimetric measurements and with a TSI SMPS, a TSI APS and a GRIMM OPS. Furthermore, samples were analyzed by electron microscopy. A bimodal particle size distribution (PSD) was obtained with the SMPS, with peaks at 20nm and around 400nm. EM analysis of >1400 single particles from the electrostatic sampler matches the PSD results. EM analysis also showed ultrafine particles, mainly from O, Fe, Si, Ba, Mg and S and also fractal particles with high C fractions. Our results suggest, in agreement with previously published literature, that particulate emissions are related to brake disc temperature and occur in significant amounts above a threshold temperature.