Xiaoke Wang

Xiaoke Wang

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
XWXiaoke Wang
Xiaoke Wang
TCTimothy J. Colgan
Timothy J. Colgan
LHLouis A. Hinshaw
Louis A. Hinshaw
NRNathan T. Roberts
Nathan T. Roberts
LBLeah C Henze Bancroft
Leah C Henze Bancroft
SRScott B. Reeder
Scott B. Reeder

24 December 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
XWXiaoke Wang
Xiaoke Wang
DHDiego Hernando
Diego Hernando
SRScott B. Reeder
Scott B. Reeder

15 May 2024 in Algorithms
Verified
Journal Article
Open access
PDF file
LZLei Zhang
Lei Zhang
XWXiaoke Wang
Xiaoke Wang
MRMichael Rawson
Michael Rawson
RBRadu Balan
Radu Balan
EHEdward Herskovits
Edward Herskovits
TEThomas Ernst
Thomas Ernst
Purpose: Motion-induced magnetic resonance imaging (MRI) artifacts can deteriorate image quality and reduce diagnostic accuracy, but motion by human subjects is inevitable and can even be caused by involuntary physiological movements. Deep-learning-based motion correction methods might provide a solution. However, most studies have been based on directly applying existing models, and the trained models are rarely accessible. Therefore, we aim to develop and evaluate a deep-learning-based method (Motion Correction-Net, or MC-Net) for suppressing motion artifacts in brain MRI scans. Methods: A total of 57 subjects, providing 20,889 slices in four datasets, were used. Furthermore, 3T 3D sagittal magnetization-prepared rapid gradient-echo (MP-RAGE) and 2D axial fluid-attenuated inversion-recovery (FLAIR) sequences were acquired. The MC-Net was derived from a UNet combined with a two-stage multi-loss function. T1-weighted axial brain images contaminated with synthetic motions were used to train the network to remove motion artifacts. Evaluation used simulated T1- and T2-weighted axial, coronal, and sagittal images unseen during training, as well as T1-weighted images with motion artifacts from real scans. The performance indices included the peak-signal-to-noise ratio (PSNR), the structural similarity index measure (SSIM), and visual reading scores from three blinded clinical readers. A one-sided Wilcoxon signed-rank test was used to compare reader scores, with p < 0.05 considered significant. Intraclass correlation coefficients (ICCs) were calculated for inter-rater evaluations. Results: The MC-Net outperformed other methods in terms of PSNR and SSIM for the T1 axial test set. The MC-Net significantly improved the quality of all T1-weighted images for all directions (i.e., the mean SSIM of axial, sagittal, and coronal slices improved from 0.77, 0.64, and 0.71 to 0.92, 0.75, and 0.84; the mean PSNR improved from 26.35, 24.03, and 24.55 to 29.72, 24.40, and 25.37, respectively) and for simulated as well as real motion artifacts, both using quantitative measures and visual scores. However, MC-Net performed poorly for images with untrained T2-weighted contrast because the T2 contrast was unseen during training and is different from T1 contrast. Conclusion: The proposed two-stage multi-loss MC-Net can effectively suppress motion artifacts in brain MRI without compromising image quality. Given the efficiency of MC-Net (with a single-image processing time of ~40 ms), it can potentially be used in clinical settings.

3 April 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
RZRuiyang Zhao
Ruiyang Zhao
YZYuxin Zhang
Yuxin Zhang
XWXiaoke Wang
Xiaoke Wang
TCTimothy J. Colgan
Timothy J. Colgan
JRJennifer L. Rehm
Jennifer L. Rehm
DHDiego Hernando
Diego Hernando

30 September 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
LZLei Zhang
Lei Zhang
XWXiaoke Wang
Xiaoke Wang
EHEdward Herskovits
Edward Herskovits
EMElias R. Melhem
Elias R. Melhem
LCLinda Chang
Linda Chang
TEThomas Ernst
Thomas Ernst
Background: Motion during magnetic resonance imaging (MRI) scans is common and can degrade image quality and reduce diagnostic accuracy. This study developed MC-Former, a motion correction method for brain MRI based on vision transformers and self-supervised learning. Methods: Motion-free brain MRI data from 52 subjects were used to generate 13,700 training, 1,950 validation, and 4,680 test axial slices from 3D sagittal T1-weighted scans acquired at 3T. MC-Former was derived from a vision transformer-based encoder-decoder architecture with skip connections. During self-supervised pre-training, 50% of patches from motion-free images were randomly masked and reconstructed; synthetic motion-corrupted images were then used for supervised training. Evaluation was performed on simulated motion-corrupted axial images unseen during training, using peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM). Results: MC-Former improved PSNR from 26.4 to 32.8 and SSIM from 0.77 to 0.94, significantly outperforming MC-Net and Restormer on the test set. For motion-free images, MC-Former achieved SSIM > 0.99. Conclusion: These results indicate that MC-Former effectively suppresses simulated motion artifacts in brain MRI while preserving artifact-free image quality. The code and trained model are available at https://github.com/MRIMoCo/MC-Former.