This study presented a new hybrid algorithm to improve the state estimation (SE) of radial distribution power systems (PSs). The proposed particle swarm optimization–neural network (PSO–NN) algorithm constructed an independent and fast monitoring system with high accuracy that can detect abnormal conditions or failures in a PS. In this study, PSO was adopted to determine the appropriate weights of the NN model. The speed and accuracy of PSO with the NN model were evaluated in the SE of power system networks (PSNs). The information obtained through SE was used to enhance the operations and customer service delivery in terms of energy consumption and power quality in PSNs. Capacitor banks were installed to reduce the losses and improve the voltage profiles. The PSO–NN algorithm was assessed on IEEE (9, 33, and 69) bus standards. Simulation results proved that the new technique can be tested on any distribution network because of its accurate and efficient SE. Results indicated that the PSO–NN algorithm had better performance than the phasor measurement units.
1 May 2020 in Indonesian Journal of Electrical Engineering and Computer Science
This paper proposes a steady-state of the Static Var Compensator (SVC) & Thyristor Controlled Series Capacitor (TCSC) set up for enhancing the damping overall performance and growing the integral clearing time (CCT) of a power network. The indispensable clearing time is carried out through increasing the time fault interval until the gadget loses stability. Increasing the CCT can be contribute to reliability of the safety gadget, decrease the protection machine ranking and cost. In order to attain most enhancement of machine stability via optimizing location, sizing and control modes of SVC and TCSC. Models and methodology for putting and designing shunt FACT’s units SVC (injected reactive strength Q) and series FACT’s devices TCSC (chose capacitive region) are examined in a 6-bus system. Performance factors are described to show validation of SVC and TCSC on extraordinary conditions. It is proven that the SVC is better than TCSC.
13 May 2025 in Arabian Journal for Science and Engineering
Power quality disturbances (PQDs) and energy management parameters (EMPs) pose significant operational challenges in radial distribution systems. Fast and accurate computational solutions are essential for efficient system performance. This study introduces a novel parallel computing approach for clustering-based PQD and EMP analysis, leveraging the density-based spatial clustering of applications with noise (DBSCAN) algorithm. The proposed method reduces processing times by more than 40% compared to sequential implementations, enabling real-time analysis and facilitating operator decision-making. A comparative evaluation with a parallel k-means approach reveals that k-means achieves slightly higher clustering efficiency, while DBSCAN provides automatic cluster selection. The methodology is validated on the IEEE 33-bus radial distribution system, where new correlations between PQD variations and their impact on EMPs are identified, offering insights for energy management optimization. The findings demonstrate that parallel computing enhances clustering performance, significantly improving computational efficiency and integration of PQD and EMP calculations for large-scale distribution networks.
This paper demonstrates the importance of the use of power system State Estimation (SE) to determine the real value of bus voltages and their angles in one line operation states. This is done to create a robust power system network that is able to monitor and analyse operational conditions and predict any emergency that may occur on the Power System Network due to human error, strong system component failure and other factors. A new hybrid (particle swarm optimization-Neural Network) algorithm is proposed to estimate the angles and voltages of buses in electrical system networks. All the results obtained from this study were compared with Phase Measurement Units (PMUs), Weighted Least Square (WLS) and Neural Network. A graph theoretic procedure algorithm (GTPA) was used to make the PMU's placements. The WLS, NN, and PMU and the new algorithm were tested on the 24 bus Iraqi Grid system. A MATLAB program was used to develop WLS codes and a hybrid (particle swarm optimization-Neural Network) algorithm. The MATLAB toolbox (PSAT and NN) were used for PMUs and Neural Network respectively. The simulation results showed that the algorithms were a good visualization and powerful system state estimation tools. The new algorithm was faster analyser than the conventional algorithm (WLS, NN, and PMU), it requires less parameter tuning. The results obtained proved the validation, acceptance and accuracy of the hybrid particle swarm optimization-Neural Network algorithm's state estimation (SE).
17 September 2019 in International Journal of Sensors, Wireless Communications and Control
Background & Objective: Harmonic amplification is one of the primary issues in power system networks. The objective of this study is to manage the harmonic event and its significant effects on power quality. A new control approach that uses Artificial Intelligence (AI) is proposed and applied to a Distribution Static Synchronous Compensator (DSTATCOM). DSTATCOM is a FACTS device that can achieve highly effective reactive power compensation to reduce and/or damp the harmonic amplification in power system networks. Results & Conclusion: Simulation results are obtained using the MATLAB/Simulink package. The validity and effectiveness of using the AI approach are proven based on the DSTATCOM FACTs device with linear and nonlinear loads. Analysis results are discussed.
1 April 2018 in International Journal of Electrical and Computer Engineering (IJECE)
This paper describes the importance of FACTS devices; it presents the outcome of the study of its reflectance on the performance of power system networks. It seeks to increase and guarantee the fact and accuracy of response systems under disturbance conditions when the phase measurement units are introduced as Real-Time Measurement (RTM) stations. This paper also describes the importance of FACTS devices. The combination of FACTS devices and PMUs is presented to increase the controllability performance of power systems. This paper demonstrates how PMUs measure voltage, current and their angles. It provides, through a communication link, a Phase Angle Data Concentrator (PDC) to make an appropriate decision to correct the power system state using the FACTS device (TCSC). We utilized the Graph-Theoretic Algorithm to optimize the number and location of PMUs. The technique proposed was tested on the Iraqi National Super Grid’s 24bus network, Diyala City’s regional 10bus network and the 14bus IEEE standard test system. The MATLAB/PSAT package was utilized for the simulation of results. It is evident that our proposed algorithm and technique achieved the purpose of this paper as confirmed by the level of accuracy of the results obtained from most of the cases tested.