Alexander Jung

Dr. Alexander Jung

Voith Hydro, Voith (Germany), Heidenheim, Baden-Württemberg, Germany
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2016 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
ANAlexandre D'Agostini Neto
Alexandre D'Agostini Neto
HGHumberto Gissoni
Humberto Gissoni
MGManuel Gonçalves
Manuel Gonçalves
RCRogério Cardoso
Rogério Cardoso
Alexander JungAlexander Jung
Alexander Jung
JMJulio Meneghini
Julio Meneghini
Despite the fact that vortex-induced vibration (VIV) in hydraulic turbines components (especially in stay vanes) is a well-known phenomenon, it still remains challenging for operation and maintenance teams in several power plants around the world. Since the first publication of a similar problem in 1967, literature shows that at least 27 other turbines witnessed strong stay vane vibrations associated with vortex shedding. Recurrent stay vane cracks in a 250 MW Francis turbine in Brazil motivated an engineering study involving prototype measurements, structural and Computational Fluid Dynamics (CFD) analysis in order to determine a proper geometry modification that could eliminate the periodic vortex wake generated at the stay vanes trailing edge. First cracks appeared in 1978 just after the machine was put into operation. A study published in 1982 associated these cracks with dynamic excitations caused by the water flow at high flow conditions. New stay vane profiles were proposed and executed as well as improved welding recommendations. Cracks however, continued to appear requiring welding repairs roughly every two years. Although Voith Hydro was not the original equipment manufacturer for these units, the necessary information was available to study the issue and propose and execute new stay vane profiles. This paper details the approach taken for the study. First, indirect vibration measurements were used to determine vibration frequencies to help to characterize the affected mode shapes. These results were compared to finite element (FE) calculations. Strain gage measurements performed afterwards confirmed the conclusions of this analysis. Next, transient CFD calculations were run to reproduce the measured phenomenon and to serve as a basis for a new stay vane geometry. This modification was then implemented in the actual turbine stay vanes. A new set of indirect vibration measurements indicated the effectiveness of the proposed solution. Final confirmation will come from new strain gage measurements.

9 April 2024 in arXiv
Verified
Preprint
Open access
PDF file
CNChristophe Nicolet
Christophe Nicolet
ABAntoine Béguin
Antoine Béguin
MDMatthieu Dreyer
Matthieu Dreyer
SASébastien Alligné
Sébastien Alligné
Alexander JungAlexander Jung
Alexander Jung
Carlos MoreiraCarlos Moreira
Carlos Moreira
This paper is addressing the quantification and the comparison of pumped storage power plants, PSPP, contribution to synchronous inertia and synthetic inertia when fixed speed and variable speed motor-generators technologies are considered, respectively. Therefore, a grid stability study was conducted by means of 1D SIMSEN simulation for the 2 x 395 MW PSPP Frades 2 in Portugal with both fixed speed and variable speed technologies in case of operation connected to an infinite power network or to an islanded 4.4 GW synchronous power network.

28 October 2026 in Energies
Verified
Journal Article
Open access
PDF file
TWTobias Weiser
Tobias Weiser
Elisa SanchezElisa Sanchez
Elisa Sanchez
MKMathis Jonah Kremling
Mathis Jonah Kremling
LGLeonard Gärtner
Leonard Gärtner
Alexander JungAlexander Jung
Alexander Jung
ABAxel Busboom
Axel Busboom
Hydropower plays an increasingly important role in sustainable energy systems. While efficient plant operation is essential, hydropower efficiency is often assessed only during commissioning or over short measurement periods, leaving long-term trends largely unexplored. This limits the early detection of performance degradation and reduces opportunities for timely maintenance and optimization. To address this gap, this paper presents a framework for continuous efficiency trend monitoring based on polynomial regression, combined with measurement uncertainty analysis to distinguish genuine performance changes from noise. Particular attention is given to data preprocessing and aggregation. The resulting regression models used to estimate turbine efficiency from operational and discharge measurements achieved root mean square error (RMSE) values between 0.149% and 0.176%. An alternative model that predicts power output from head and guide vane opening yielded an RMSE of 0.28% in the most frequently used operating range. The resulting residuals were tracked over time and remained within the confidence levels defined by measurement uncertainty. Seasonal effects were also evident in the results, demonstrating the potential of the proposed approach for long-term monitoring of hydropower plant performance.