Bruno Henriques

Prof. Dr. Bruno Henriques

Mechanical Engineering Department, Federal University of Santa Catarina, Florianópolis/SC, Brazil
+1
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2019 in Acta Biomaterialia
Verified
Journal Article
Closed access
Júlio C. M. SouzaJúlio C. M. Souza
Júlio C. M. Souza
MSMariane Sordi
Mariane Sordi
MKMiya Kanazawa
Miya Kanazawa
SRSriram Ravindran
Sriram Ravindran
Bruno HenriquesBruno Henriques
Bruno Henriques
LCLyndon F. Cooper
Lyndon F. Cooper

1 May 2019 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
FSFernanda H. Schünemann
Fernanda H. Schünemann
MGMaría E. Galárraga-Vinueza
María E. Galárraga-Vinueza
RMRicardo Magini
Ricardo Magini
MFMarcio C. Fredel
Marcio C. Fredel
Filipe SilvaFilipe Silva
Filipe Silva
Bruno HenriquesBruno Henriques
Bruno Henriques

2 August 2017 in Journal of Periodontal Research
Verified
Journal Article
Open access
PDF file
MOM. Noronha Oliveira
M. Noronha Oliveira
WSW. V. H. Schunemann
W. V. H. Schunemann
MMM. T. Mathew
M. T. Mathew
Bruno HenriquesBruno Henriques
Bruno Henriques
RMR. S. Magini
R. S. Magini
Júlio C. M. SouzaJúlio C. M. Souza
Júlio C. M. Souza
This study aimed to assess the literature available on the effects, on peri‐implant tissues, of degradation products released from dental implants as a consequence of therapeutic treatment for peri‐implantitis and/or of wear‐corrosion of titanium. A literature review of the PubMed medline database was performed up to December 31, 2016. The following search terms were used: “titanium wear and dental implant”; “titanium corrosion and dental implant”; “bio‐tribocorrosion”; “peri‐implantitis”; “treatment of peri‐implantitis”; “titanium particles release and dental implant”; and “titanium ion release and dental implant”. The keywords were applied to the database in different combinations without limits of time period or type of work. In addition, the reference lists of relevant articles were searched for further studies. Seventy‐nine relevant scientific articles on the topic were retrieved. The results showed that pro‐inflammatory cytokines, infiltration of inflammatory response cells and activation of the osteoclasts activity are stimulated in peri‐implant tissues in the presence of metal particles and ions. Moreover, degenerative changes were reported in macrophages and neutrophils that phagocytosed titanium microparticles, and mutations occurred in human cells cultured in medium containing titanium‐based nanoparticles. Debris released from the degradation of dental implants has cytotoxic and genotoxic potential for peri‐implant tissues. Thus, the amount and physicochemical properties of the degradation products determine the magnitude of the detrimental effect on peri‐implant tissues.

5 January 2019 in Resources
Verified
Journal Article
Open access
PDF file
TSThamyres Hellen Da Silva
Thamyres Hellen Da Silva
JMJoana Mesquita-Guimaraes
Joana Mesquita-Guimaraes
Bruno HenriquesBruno Henriques
Bruno Henriques
Filipe SilvaFilipe Silva
Filipe Silva
MFMarcio C. Fredel
Marcio C. Fredel
Calcium carbonate is one of the most used raw materials in various industries, such as construction materials, food supplement, pharmaceutics, animal feed, plastic production, and others. Calcium carbonate can derive from marine wastes, like crustaceans and bivalve’s shells. The worldwide demand for new sources of food has increased exponentially, and following that tendency, the mariculture—especially the oyster culture—has been increasingly resorting to farming techniques. In 2016, 438 billion tons of oysters were produced. The majority of the shells were unduly discarded, presenting a public health problem. This article offers a solution based on the reuse and recycling of oyster shell residues in the production region of Florianópolis, SC, Brazil. The presented solution is an oyster shell by-product developed by a local company which produces artificial stone. The main component of the artificial stone is a composite material made of oyster shells incorporated in a polymeric resin. The mechanical properties, such as its flexural strength, hardness, Weibull modulus, and fracture analysis, were held in the artificial stone. The mechanical results of the new artificial stone were compared with other natural stones, such as granite and marble, and other commercial artificial stones. This material owns suitable mechanical properties for table tops and workbenches. Using this product as an artificial stone represents an innovation in the development of a new product and adds commercial value to local waste. This product is an excellent example of a circular economy for local producers who care about the environment, and it encourages the reduction of extraction of natural stone, such as granite and marble.

14 June 2017 in Journal of Periodontal Research
Verified
Journal Article
Closed access
PDF file
KAKarin Apaza-Bedoya
Karin Apaza-Bedoya
MTM. Tarce
M. Tarce
CBC. A. M. Benfatti
C. A. M. Benfatti
Bruno HenriquesBruno Henriques
Bruno Henriques
MMM. T. Mathew
M. T. Mathew
Júlio C. M. SouzaJúlio C. M. Souza
Júlio C. M. Souza

1 December 2016 in Materials Letters
Verified
Journal Article
Closed access
PMPatricia R. Monich
Patricia R. Monich
Bruno HenriquesBruno Henriques
Bruno Henriques
AOAntonio Pedro Novaes Oliveira
Antonio Pedro Novaes Oliveira
Júlio C. M. SouzaJúlio C. M. Souza
Júlio C. M. Souza
MFMarcio C. Fredel
Marcio C. Fredel